文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数16个

设置提升方向
生物基质
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES · 2025 · IF 2.8

Unraveling the in vivo pharmacokinetic behavior of mPEG5-NH2 polymer in rats by UHPLC-MS/MS assay

Yingxia Guo,Meichen Liu,Jiye Tian,Chunpeng Feng,Qingbin Wang,Xuan Zhao,Lei Yin

As an important chemical reagent, methoxy polyethylene glycol amine (mPEG-NH 2 ) is widely used in biomedical field. Unraveling the pharmacokinetic behavior of mPEG-NH 2 polymers is essential for revealing the toxicity and efficiency of mPEG-NH 2 related drug delivery systems. In this study, a simple analytical assay based on mass spectrometry (MS) was first established and validated for quantification of mPEG 5 -NH 2 in biological matrix. The multiple reaction monitoring (MRM) transitions at m / z 252.2 (precursor ions) → 87.7 (fragment ions) and m / z 371.2 (precursor ions) → 89.2 (fragment ions) were chosen to determine mPEG 5 -NH 2 and OH-PEG 8 -OH, respectively. The UHPLC-MS/MS assay showed excellent linearity over the range of 0.01–10 μg/mL. Intra-day and inter-day accuracies and precisions of the assay were all within ± 6.44 %. The analytical assay was successfully applied to reveal the in vivo pharmacokinetic behavior of mPEG 5 -NH 2 in rats.

研究领域: 药理学 · 分析化学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS · 2017 · IF 3.255

Fabrication of a novel hemin-based monolithic column and its application in separation of protein from complex bio-matrix

Xiaoya Jiang,Doudou Zhang,Xueying Li,Xixi Wang,Ligai Bai,Haiyan Liu,Hongyuan Yan

A novel polymer-based monolithic column was prepared via redox initiation system within the confines of a stainless steel column with 4.6   mm i.d. In the processes, hemin and lauryl methacrylate were used as co-monomers; ethylene dimethacrylate as crosslinking agent; n-butyl alcohol, ethanediol, and N , N -dimethylformamide as tri-porogens; benzoyl peroxide and N , N -dimethyl aniline as redox initiation system. The resulting polymer-based monolithic columns were characterized by scanning electron microscopy, nitrogen adsorption-desorption instrument, and mercury intrusion porosimeter, respectively. The results illustrated that the improved monolith had relative uniform porous structure, good permeability, and low back pressure. Aromatic compounds were used to test the chromatographic behavior of the monolith, resulting in highest column efficiency of 19 880 plates per meter with reversed-phase mechanism. Furthermore, the homemade monolith was used as the stationary phase of high performance liquid chromatography to separate proteins from complex bio-matrix, including human plasma, egg white, and snailase. The results showed that the monolithic column occupied good separation ability with these complex bio-samples. Excellent specific character of the homemade hemin-based monolith was that it could simultaneously remove high-abundance proteins (including human serum albumin, immunoglobulin G, and human fibrinogen) from human plasma and separate other proteins to different fractions.

研究领域: 分析化学 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Biosensors-Basel · 2024 ·Vol. 14 ·期 6 ·271 · IF 4.9

Rapid Separation and Detection of Drugs in Complex Biological Matrix Using TD-CDI Mass Spectrometer

Wenyan Shi,Zi Ye,Qin Yang,Jianhua Zhou,Jiasi Wang,Xinming Huo

The drug detection technology plays a pivotal role in the domains of pharmaceutical regulation and law enforcement. In this study, we introduce a method that combines thermal desorption corona discharge ionization (TD-CDI) with mass spectrometry for efficient drug detection. The TD-CDI module, characterized by its compact and simple design, enables the separation of analytes within seconds and real-time presentation of one or two analyte peaks on the mass spectrum most of the time, which reduces matrix interference and improves detection performance. Through experimental investigation, we studied the characteristics of TD-CDI for analyte separation and detection, even with the same mass number, and optimized the TD-CDI approach. TD-CDI-MS was employed for the rapid detection of drugs in various traditional medicine, food products, and human samples. Additionally, by utilizing TD-CDI for segmented hair direct analysis, it becomes possible to trace the drug usage cycle of individuals. This underscores the feasibility of the proposed analytical method within the realm of drug detection.

研究领域: 分析化学 · 药理学 · 法医学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
TRIBOLOGY INTERNATIONAL · 2022 · IF 5.62

Simultaneous low friction and ultra-low wear enabled by a 2,5-Furandicarboxylic acid derived bio-based ionic liquid

Xinxin Ruan,Huanyi Chen,Chengcheng Jiao,Xianzhe Wei,Yandong Wang,Ping Gong,Lexin Song,Kazuhito Nishimura,Jinhong Yu,Nan Jiang,Tao Cai

Bio-based protic ionic liquids (bio-PILs) based on 2,5-Furandicarboxylic acid and polyetheramine was synthesized, which was explored as a neat lubricant and lubricant additive for different alcohols that has different hydroxyl numbers under varied test conditions. Long-term service performance testing showed that the bio-PILs could achieve ultra-low coefficient of friction and wear simultaneously, which decreased coefficient of friction of 95.94% and wear rate of 99.87% compared to dry friction under Si 3 N 4 -to-steel tribo-pairs. The distinguished tribological performance is contributed to the bio-PILs can absorb on the rubbing surface and form a lubricating protective film to avoid direct contact of super hard upper Si 3 N 4 ball against lower steel plate. This work presents a facile approach to synthesize high-performance bio-based protic ionic liquids using biomass as bridging agent and provides new insight into the underlying lubricating mechanism, which might help guide the development of novel bio-based lubricants in the future.

研究领域: 材料科学 · 摩擦学 · 化学工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHROMATOGRAPHIA · 2019 ·Vol. 83 ·期 2 ·173-181 · IF 1.552

Simultaneous Determination of Six Alkaloids in Rat Plasma with On-line SPE–HPLC Using a Homemade Four-Hydrogen Furfuryl-Based Polymer Monolithic Sorbent

Li Mingxue,Bai Ligai,Sun Fanrong,Peng Shan,Liu Haiyan,Ma Zhengyue

Abstract A four-hydrogen furfuryl-based polymer monolithic column for solid-phase extraction was prepared via in situ radical polymerization, using tetrahydrofurfuryl methacrylate as the monomer. The monolith was characterized by scanning electron microscopy, Fourier-transform infrared spectroscopy and nitrogen adsorption–desorption method, showing relatively uniform porous structure with micro-, meso- and macro-pores and a relatively high surface area of 54.99 m 2  g −1 . Online solid-phase extraction–high-performance liquid chromatography was carried out to quantitatively analyze six alkaloids, including caffeine, hydroxy-α-sanshool, hydroxy-β-sanshool, hydroxy-γ-sanshool, hydroxy-γ-isosanshool and γ-sanshool in rat plasma. The results show that the prepared polymer monolithic sorbent exhibits good clean-up ability for bio-matrix, as well as good extractive ability for the six concerning alkaloids in rat plasma. Method validation shows that the correlation coefficients of the linear regressions are higher than 0.998 and the accuracy represented by spiked recovery ranges in 94.37–100.7%, 99.52–101.1%, 98.93–100.8%, 98.36–101.6%, 99.22–101.2% and 99.86–101.4% for the six alkaloids, respectively, as well as the LOD ranges in 2.10–3.90 ng mL −1 and the LOQ in 6.35–10.14 ng mL −1 . Compared to the reference works, the present work is a simple and effective method for online extraction and simultaneous determination of six alkaloids in plasma with high accuracy and low cost. Graphic Abstract

研究领域: 分析化学 · 药理学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2025 · IF 6.7

Simultaneous Profiling of Multiple Phosphorylated Metabolites in Typical Biological Matrices via Ion-Pair Reversed-Phase Ultrahigh-Performance Liquid Chromatography and Mass Spectrometry

Huan Wang,Qinsheng Chen,Yuanpeng Wu,Li Xu,Qi Wang,Qingyu Hu,Huiru Tang

Simultaneous analysis of multiple phosphorylated metabolites (phosphorylated metabolome) in biological samples is vital to reveal their physiological and pathophysiological functions, which is extremely challenging due to their low abundance in some biological matrices, high hydrophilicity, and poor chromatographic behavior. Here, we developed a new method with ion-pair reversed-phase ultrahigh-performance liquid chromatography and mass spectrometry using BEH C18 columns modified with hybrid surface technology. This method demonstrated good performances for various phosphorylated metabolites, including phosphorylated sugars and amino acids, nucleotides, NAD-based cofactors, and acyl-CoAs in a single run using standard LC systems. Specifically, the method showed good retention (capacity factor > 2) and reproducibility (ΔtR < 0.09 min, n = 6), peak symmetry (tailing factor < 2), and sensitivity (limit-of-detection < 238 fmol-on-column with QTOFMS) for all tested analytes especially for the medium- and/or long-chain acyl-CoAs. The method demonstrated reproducible applicability across numerous biological matrices, including tissue (liver), human biofluids (urine, plasma), cells, and feces, and revealed significant molecular phenotypic differences in phosphorylated metabolite composition.

CAS / MDL: 631-61-8
研究领域: 分析化学 · 代谢组学 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Nanoscale · 2017 ·Vol. 9 ·期 33 ·11912-11919 · IF 7.367

A label-free and universal platform for the construction of an odd/even detector for decimal numbers based on graphene oxide and DNA-stabilized silver nanoclusters

Siqi Zhang,Kun Wang,Kai-Bin Li,Fengzao Chen,Wei Shi,Wen-Ping Jia,Jie Zhang,De-Man Han

Molecular logic devices with different functions can perform various tasks in the areas of biological molecule detection, disease diagnosis, multivariate analysis, and bioimaging. Herein, a series of logic circuits based on silver nanoclusters (AgNCs)/graphene oxide (GO) are constructed to execute nonarithmetic functions, including 3-, 4-, and 5-bit odd/even checking. The resulting devices can differentiate between even and odd decimal numbers in the range from 0 to 31. Moreover, the devices can be expanded to operate with wider ranges of numbers when more inputs are added. The signal reporter is structured using AgNCs and GO, preventing laborious modification of biomolecules. The designed DNA-based logic nanodevices share the same DNA platform and a constant threshold value, showing great potential for application in information processing at the molecular level. Additionally, these devices can stably carry out their logic operations in a biological matrix, indicating that the AgNC/GO-based system can operate in a complicated biological environment. Given the biocompatibility and design flexibility of DNA, this study provides novel outcomes towards the development of label-free intelligent nanodevices. This may open a new path for the application of AgNCs/GO in molecular logic circuits and fluorescence imaging.

CAS / MDL: 16940-66-2 7761-88-8
研究领域: 纳米技术 · 分子生物学 · 生物医学工程 · 化学工程 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF SEPARATION SCIENCE · 2021 ·Vol. 44 ·期 21 ·3914-3923 · IF 3.645

Simultaneous determination of nine tyrosine kinase inhibitors in three complex biological matrices by using high-performance liquid chromatography–diode array detection combined with a second-order calibration method

Zhao-Yang Wang,Hai-Long Wu,Yue-Yue Chang,Tong Wang,Wei Chen,Gao-Yan Tong,Ru-Qin Yu

An intelligent chemometric second-order calibration method called alternating trilinear decomposition- assisted multivariate curve resolution combined with high-performance liquid chromatography–diode array detection was used for the simultaneous quantification of nine tyrosine kinase inhibitors in three complex biological systems. The method allows simultaneous quantification of the components in different biological matrices without the need for cumbersome pre-treatment steps, complex elution conditions, and complete peak separation. Even with the varying time shift, severe peak overlap, and various unknown interferences, the proposed method can extract pure chromatographic and spectroscopic information for each analyte, while providing accurate qualitative and quantitative results of nine common tyrosine kinase inhibitors in three different biological matrices. All the drugs were eluted in 7 min. The results showed that the nine drugs in each matrix showed good linearity ( r > 0.984) in the calibration range with a root mean square error of calibration less than 0.9 μg/mL. The average spiked recoveries of the target analytes were all in the range of 83.4–110.0%, with standard deviations less than 9.0%. Finally, the classical method was used to validate the proposed method. In comparison to the traditional method, the proposed strategy is accuracy, simultaneous, and interference-free.

研究领域: 分析化学 · 药物分析 · 生物医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL LETTERS · 2023 · IF 2

Optical Determination of Tryptophan Using Persistent Luminescence Nanoparticles (PLNPs)

Zhenmin Zhai,Zhefeng Fan

Tryptophan is an essential amino acid that is an important part of the human diet. In this work, label-free photoluminescence sensing based upon persistent luminescent nanoparticles (PLNPs) Zn0.8Ga2O4: Cr3+ is reported to determine tryptophan. Following 254 nm excitation, the PLNPs released luminescence after storing the absorbed light. Compared to the standard fluorescence, the persistent afterglow of the PLNPs was used for detection and imaging without external illumination, thereby eliminating autofluorescence and scattered light generated by biological substrates. For tryptophan concentrations from 4 to 240 µM, a linear relationship was described by F/F0 = 0.9416 − 0.0024 [Trp] with a correlation coefficient of 0.9911 and a detection limit of 0.19 µM. The recoveries of analyzed samples were between 97.9 and 101.9% providing good accuracy and simple methodology.

CAS / MDL: 13494-90-1
研究领域: 分析化学 · 纳米技术 · 生物医学工程 · 生物化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Journal of Materials Chemistry B · 2018 ·Vol. 6 ·期 46 ·7703-7709 · IF 4.776

Improving the adsorption capacity for ovalbumin by functional modification of aminated mesoporous silica nanoparticles with tryptophan

Min Qiao,Xun Liu,Jin-Wei Song,Ting Yang,Ming-Li Chen,Jian-Hua Wang

Tryptophan (Trp) modified aminated mesoporous silica nanoparticles (AMSNs), shortened to Trp-AMSNs, are prepared via covalent binding. The obtained Trp-AMSNs exhibit a uniform size of ca. 83 nm, a mesopore diameter of ca. 2.6 nm, along with a pore volume of 0.439 cm3 g−1. It is demonstrated that Trp-AMSNs selectively adsorb ovalbumin (Ova) from complex biological matrices. At pH 5.0, 1.0 mg of Trp-AMSNs produces an adsorption efficiency of 96% for 100 mg L−1 Ova in 1.0 mL of solution. An adsorption capacity of 1240.3 mg g−1 is derived for Ova, which is much improved with respect to that of the native AMSNs. The retained Ova could be readily recovered by a sodium dodecyl sulfate (SDS) solution (0.5%, m/v), providing a recovery of 71.2%. Trp-AMSNs are further applied for the isolation of Ova from a protein mixture (with a molar ratio of ovalbumin/lysozyme of 1 : 10) and an egg-white sample. High-purity Ova is obtained, as demonstrated by SDS-PAGE assay results.

研究领域: 纳米技术 · 生物化学 · 材料科学 · 蛋白质工程
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF SEPARATION SCIENCE · 2022 ·Vol. 46 ·期 1 ·2200725 · IF 3.614

Cellular toxicity and pharmacokinetic study of butachlor by ultra-performance liquid chromatography-tandem mass spectrometry based on tandem mass spectrometry cubed technique

Xinyue Zheng,Xujian Duan,Di Lu,Qiuhong Jiang,Yajun Liu,Hongyu Xue,Jiansong You,Lei Yin,Meiyun Shi

Butachlor is an aromatic amide compound that plays a role as a herbicide, a xenobiotic, and an environmental contaminant. The aim of this work was to develop a highly selective and sensitive ultra-performance liquid chromatography-tandem mass spectrometry method based on the tandem mass spectrometry cubed technique to determine butachlor in a biological matrix. Butachlor and internal standard acetochlor were separated on a Waters Acquity ultra-performance liquid chromatography BEH C 18 column (2.1 × 50 mm, 1.7 μm) with gradient elution using 0.1% formic acid aqueous solution (A) and acetonitrile (B) as mobile phases. The transitions selected for tandem mass spectrometry cubed quantitative analysis in positive ion mode were: for butachlor, mass-to-charge ratio 312.2→238.1→162.1; for acetochlor, mass-to-charge ratio 270.1→224.0→148.1. The total running time for each sample was 5.5 min. The ultra-performance liquid chromatography-tandem mass spectrometry cubed method showed a linear relationship ( R 2 ≥ 0.995) in the concentration range of 0.5–100 ng/ml. The intra and interday accuracies are within the range of -10.6%–4.3% and precisions are between 4.48% and 13.14%. The novelty of the method is the use of tandem mass spectrometry cubed scanning mode, which improves selectivity and sensitivity. The results indicated that butachlor was cellular toxic. The safety of butachlor should be considered when it is used as a herbicide.

CAS / MDL: 34256-82-1 23184-66-9
研究领域: 分析化学 · 毒理学 · 环境科学 · 药理学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2014 · IF 5.825

2-Pyridylfuran: A New Fluorescent Tag for the Analysis of Carbohydrates

Zhi Peng Cai,Andrew Kevin Hagan,Mao Mao Wang,Sabine Lahja Flitsch,Li Liu,Josef Voglmeir

We herein report the use of 1,3-di(2-pyridyl)-1,3-propanedione (DPPD) as a fluorogenic labeling reagent for sugars. Reaction of DPPD with the anomeric carbon affords a fluorescent 2-pyridylfuran (2-PF) moiety that permits the sensitive HPLC-based detection of monosaccharides. 2-PF-labeled monosaccharides can be easily separated and analyzed from mixtures thereof, and the reported protocol compares favorably with established labeling reagents such as 2-aminobenzoic acid (2-AA) and 1-phenyl-3-methyl-5-pyrazolone (PMP), ultimately allowing subfemtomole detection of the galactose-derived product. Furthermore, we demonstrate the application of DPPD in the labeling of monosaccharides in complex biological matrices such as blood and milk samples. We envisage that DPPD will prove to be an excellent choice of labeling reagent in monosaccharide and carbohydrate analysis.

研究领域: 分析化学 · 碳水化合物化学 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。