文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数2,799个

设置提升方向
电化学传感器
JOURNAL OF THE ELECTROCHEMICAL SOCIETY · 2016 ·Vol. 163 ·期 9 ·B526 · IF 3.014

Hemin Modified TiO2 Nanoparticles with Enhanced Photoelectrocatalytic Activity for Electrochemical and Photoelectrochemical Sensing

Yuhan Zhu,Kai Yan,Zuwei Xu,Jingdong Zhang

Hemin-functionalized TiO2 nanoparticles were prepared and assembled on glassy carbon electrode through the electrostatic attraction between positively charged poly(diallyldimethylammonium chloride) and negatively charged hemin and TiO2. The scanning electron microscopy and X-ray diffraction characterization showed that the assembled hemin-TiO2 film displayed a mesoporous structure comprising plenty of TiO2 nanoparticles in rutile phase. The Fourier transform infrared spectra and UV-visible diffuse reflectance spectra indicated that hemin was successfully incorporated into TiO2 film and significantly enhanced the absorption of TiO2 film to visible light. The hemin-TiO2 film exhibited a pair of well-defined redox peaks of hemin by cyclic voltammetry, which could effectively catalyze the electroreduction of H2O2. Thus, the hemin-TiO2 modified electrode was employed as an electrochemical sensor for H2O2 determination, showing a sensitive response linearly proportional to the concentration of H2O2 from 3.0 × 10−7 to 4.7 × 10−4 mol·L−1. At the same time, the photoelectrocatalytic activity of TiO2 under visible light illumination was dramatically promoted by hemin. The hemin-TiO2 modified electrode produced a photoelectrochemical response linearly proportional to hydroquinone in the concentration range from 4.0 × 10−7 to 3.0 × 10−5 mol·L−1.

研究领域: 分析化学 · 材料科学 · 生物传感
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
BIOELECTROCHEMISTRY · 2025 · IF 4.5

Garnering sensitivity: A horseradish peroxidase and MoS2@black phosphorene based electrochemical biosensor for glyphosate detection

Lisi Wang,Xiaoqing Li,Baoli Wang,Fan Shi,Brij Mohan,Mansoor Ahmad,Wei Sun

Glyphosate (GLY) is one of the most widely used herbicides, and the presence of its residues in food samples poses a threat to human health. Developing a monitoring system could help address food safety concerns. This study presents an innovative electrochemical sensing platform to detect GLY, which employs molybdenum disulfide (MoS 2 ) and black phosphorene (BP) nanocomposites (MoS 2 @BP) with horseradish peroxidase (HRP) for the working electrode modification. The MoS 2 @BP nanocomposite is synthesized using a hydrothermal method, and its characteristics are investigated through different methods including scanning electron microscopy, X-ray photoelectron spectroscopy, and X-ray diffraction methods. The presence of BP enhances electrical conductivity and increases specific surface area, while MoS 2 improves the electrochemical properties of the composites and provides a protective effect on BP. The modification of MoS₂@BP on the electrode surface helps to accelerate the direct electron transfer of HRP with enhanced electrochemical responses. Furthermore, the incorporation of amino acid residues from HRP significantly enhances the recognition of GLY, thereby improving the selectivity and sensitivity of this electrochemical sensor. The sensor operates effectively within a linear concentration range from 0.118 nmol/L to 20.65 μmol/L, with a low detection limit of 0.0393 nmol/L (3σ). Furthermore, the sensor is successfully applied to detect GLY in real cornmeal samples with satisfactory results, demonstrating its potential applications in food safety monitoring.

CAS / MDL: 31175-20-9
研究领域: 食品科学 · 环境科学 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MOLECULES · 2023 ·Vol. 28 ·期 14 ·5316 · IF 4.6

Portable Microelectrochemical Sensors for Rapid and Sensitive Determination of Hesperidin in Citrus reticulate ‘Chachi’ Peel

Hong-Qi Xia,Wanbing Chen,Diyang Qiu,Jiwu Zeng

Portable and low-cost analytical devices are essential for rapid detection of bioactive substrates in agricultural products. This study presents the first highly integrated microelectrochemical sensor based on pencil graphite for rapid and sensitive detection of hesperidin inCitrus reticulate‘Chachi’ peel. The surface morphology and characterization as well as the electrochemical property of pencil graphite was investigated and discussed. A high electrocatalytic efficiency of hesperidin has been found at used pencil graphite-based microelectrodes. Kinetic analysis was carried out to further understand the electrochemical process of hesperidin at a pencil graphite microelectrode. Consequently, a portable and highly-integrated microelectrochemical sensor exhibits a sensitivity of 0.7251 μA cm−2μM−1and a detection limit as low as 25 nM (S/N = 3), and high selectivity was fabricated. Proposed microelectrochemical sensors were applied to electrochemically determinate the hesperidin content in the extract ofCitrus reticulata“chachi” peel. As a result, the concentration of hesperidin in the actual real sample detected electrochemically with the proposed portable and low-cost microelectrochemical sensors is highly consistent to that obtained with a common chromatographic method, thus indicating the good reliability and that it can be used in practical applications.Keywords:microelectrochemical sensor;hesperidin;Citrus reticulata“chachi”

CAS / MDL: 520-26-3
研究领域: 分析化学 · 食品科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICA CHIMICA ACTA · 2022 · IF 6.911

Simultaneous detection of Cd2+ and Pb2+ in food based on sensing electrode prepared by conductive carbon paper, rGO and CoZn·MOF (CP-rGO-CoZn·MOF)

Yanli Qi,Xiaolong Chen,Danqun Huo,Huan Liu,Mei Yang,Changjun Hou

Cd 2+ and Pb 2+ are two typical metallic pollutants in food. Therefore, it is of great significance to establish a method which can simultaneously detect them. Here, an electrochemical sensor was established to simultaneously detect Cd 2+ and Pb 2+ in food samples based on sensing electrode prepared by conductive carbon paper, rGO and CoZn·MOF (CP-rGO-CoZn·MOF). Under the optimized conditions, the proposed electrochemical sensor achieves simultaneous detection of Cd 2+ and Pb 2+ low to 0.565 nM (Cd 2+ ) and 0.588 nM (Pb 2+ ), respectively. Further selective experiments and repetitive experiments perform well. Spiked experiments find that the recovery rates of Cd 2+ and Pb 2+ in food samples are between 97.5% to 105.9% and 94.3%–109.6%, indicating the established electrochemical sensor owns a good response to the targets. Besides, relative standard deviations (RSD) of them are no more than 5.817%, showing its potential in practical applications.

研究领域: 分析化学 · 食品安全 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOELECTROCHEMISTRY · 2022 · IF 5.76

An electrochemical DNA sensor based on an integrated and automated DNA walker

Hao Fan,Ying Wu,Tongfu Huang,Nian Hong,Hanfeng Cui,Guobing Wei,Fusheng Liao,Jing Zhang

As an artificial nanomachine, a DNA walker demonstrates the potential for biosensing. In this study, a highly integrated, biostable, and autonomous electrochemical DNA walker sensor was rationally designed by a simple assembly of a Mn 2+ -dependent DNAzyme-powered DNA walker with nanoscale Mn 2+ @MOFs containing free carboxylic acid groups UiO-66(Zr)-(COOH) 2 . In this study, the release of Mn 2+ from Mn 2+ @MOFs was exploited to drive the autonomous and progressive operation of the DNA walker, and the DNAzyme-driven DNA walker was constructed by the co-modification of walking strands and track strands onto the gold electrode (GE) surface. The walking strand was a single-stranded DNA containing a DNAzyme sequence, which was pre-silenced by the locking strand. The track strand was a specially designed DNA sequence that the target can hybridize with the locking strand; hence, the walking strand is unlocked, and the liberated DNAzyme catalyzes the cleavage of track strands to drive the DNA walker operation, shifting tetraferrocene away from the electrode and producing a significant signal change. A detection limit of 38 fM was obtained with our new system, exhibiting a wide linear range from 1.5625 × 10 −9 M to 1 × 10 −13 M. The proposed approach provided a novel means for constructing an highly integrated, automated, and DNAzyme-driven DNA walker for bioanalysis.

研究领域: 生物传感 · 纳米技术 · 分子生物学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Omega · 2022 · IF 4.132

Ultrasensitive Detection of Carcinoembryonic Antigen by Chitosan/Polythiophene/CdTe Electrochemical Biosensor

Jiajia Wang,Xin Hua,Baokang Jin

A facile method for the in situ fabrication of chitosan/polythiophene/CdTe (CS/PTh/CdTe) nanocomposite has been developed. It was then connected with anti-CEA (Ab), which was evoked for the electrochemical detection of carcinoembryonic antigen (CEA, Ag) within K4Fe(CN)6. The results indicate that CS/PTh/CdTe/GCE has a high selectivity for the detection of CEA with a wide linear range of 0.0001–10000 ng/mL and excellent sensitivity with a low detection limit of 40 fg/mL. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), and in situ FT-IR spectra are evoked to study the mechanism of detection of CEA via CS/PTh/CdTe/GCE. The high sensitivity of the electrochemical sensor is due to the fact that the electrochemical oxidation products of K4Fe(CN)6 can directly oxidize CdTe from a low energy state to a high energy state (CdTe)*, making CdTe more prone to be oxidized and facilitate electron transfer. The developed electrochemical biosensor can be used for the detection of real samples, providing a precise method for the detection of CEA with potential application in the clinical detection of tumors.

研究领域: 生物医学工程 · 分析化学 · 肿瘤学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
International Journal of Electrochemical Science · 2023 · IF 1.5

Electrochemical detection of hydroquinone based on marine biomass carbon from shrimp shells as electrode modifier

Yang Liu,Zejun Zhang,Yushu Li,Fan Shi,Yijing Ai,Baoli Wang,Siyue Zhang,Xiaoping Zhang,Wei Sun

An electrochemical sensor based on marine biomass shrimp shell-derived porous carbon (SSPC) modified glassy carbon electrode (GCE) was developed for the detection of hydroquinone (HQ) in this paper. The resultant SSPC was characterized by different methods including scanning electron microscopy and Fourier transform infrared spectroscopy. Brunauer-Emmett-Teller method was used to evaluate the pore structure and surface area of SSPC. The electrochemical behaviors of SSPC/GCE were explored by cyclic voltammetry and differential pulse voltammetry. The SSPC/GCE demonstrated linear response ranges of 5.0–25.0 μM and 25.0–1200.0 μM for HQ analysis with the limit of detection as 0.18 μM (S/N = 3). Additionally, the method had been successfully applied to determine HQ in real lake water sample, which provided potential applications in further sensing study.

研究领域: 材料科学 · 环境科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ENVIRONMENTAL RESEARCH · 2023 · IF 8.3

Nanohybrid of antimonene@Ti3C2Tx-based electrochemical aptasensor for lead detection

Zhouxiang Zhang,Hassan Karimi-Maleh,Yangpin Wen,Rozhin Darabi,Tao Wu,Pardis Alostani,Masoumeh Ghalkhani

Lead ions (Pb 2+ ), as one of many common heavy metallic environmental pollutants, can cause serious side-effects and result in chronic poisoning to people's health, so it is highly significant to monitor Pb 2+ efficiently and sensitively. Here, we proposed an antimonene@Ti 3 C 2 T x nanohybrid-based electrochemical aptamer sensor (aptasensor) for high sensitive Pb 2+ determination. The sensing platform of nanohybrid was synthesized by ultrasonication, possessing the advantages of both antimonene and Ti 3 C 2 T x , which not only can vastly enlarge the sensing signal of the proposed aptasensor, but also greatly simplified its manufacturing flow, because antimonene can strongly interact with aptamer through noncovalently bound. The surface morphology and microarchitecture of the nanohybrid were perused by several methods such as scanning electron microscope (SEM), energy-dispersive X-ray mapping spectroscopy (EDS), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), and atomic force microscope (AFM). Under optimal empirical conditions, the proposed aptasensor exhibited a wide linear correlation of the current signals with the logarithm of C Pb 2+ (Log C Pb 2+ ) over the span from 1 × 10 −12 to 1 × 10 −7  M and provided a trace discernment limit of 3.3 × 10 −13  M. Moreover, the constructed aptasensor displayed superior repeatability, great consistency, eminent selectivity , and beneficial reproducibility, implying its extreme potential application for water quality control and the environmental monitoring of Pb 2+ .

研究领域: 环境科学 · 分析化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2021 · IF 7.46

Electrochemical sensor based on graphdiyne is effectively used to determine Cd2+ and Pb2+ in water

Ying Li,Huan Huang,Rongli Cui,Dongmei Wang,Zi Yin,Dan Wang,Lirong Zheng,Jing Zhang,Yidong Zhao,Hui Yuan,Jinquan Dong,Xihong Guo,Baoyun Sun

In this work, graphdiyne, a new kind of carbon allotrope composed of sp and sp 2 hybridized carbon atoms, firstly worked as an effective electrochemical sensor for the determination of low concentration of Cd 2+ and Pb 2+ in water using electrochemical pre-enrichment and anodic-stripping voltammetry methods. The limit of detection was 0.46 nM for Cd 2+ and 1.72 nM for Pb 2+ with a linear range extended from 0.01 μM to 1 μM. This graphdiyne modified electrode also presented excellent selectivity, stability, applicability and reproducibility, providing a simple and promising platform to develop novel electrochemical sensor for detecting Pb 2+ and Cd 2+ with higher performance. Through X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared (FTIR) and X-ray absorption near edge structure (XANES) characterization, it was verified that the acetylenic links in graphdiyne served as adsorbent sites by providing electrons to bind with heavy metal ions, which enhanced the electrochemical sensing performance.

CAS / MDL: 31175-20-9
研究领域: 分析化学 · 材料科学 · 环境科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Micro & Nano Letters · 2018 ·Vol. 13 ·期 10 ·1382-1385 · IF 0.841

Synthesis of columnar-shaped CeO2 and electrochemical sensor for detecting phenol

Xin Xiao,YiHui Wang,DongEn Zhang,JunYan Gong,Ying Zhang,JuanJuan Ma,Tao Yang,ZhiWei Tong

Highly uniform columnar-shaped CeO 2 was successfully prepared in large quantities by calcining a precursor, which was prepared by a simple hydrothermal method. The structure and morphology of the precursor and the columnar CeO 2 were characterised by X-ray diffraction and scanning electron microscopy. The columnar CeO 2 was fixed on a glassy carbon electrode to obtain a columnar CeO 2 sensor for detection of phenol. The anodic peak current was proportional to the phenol concentration in the range of 0.005–0.225 mmol l −1 ( R = 0.995) and 0.225–1.125 mmol l −1 ( R = 0.998) with the detection limit of 0.9 μmol l −1 . This electrochemical method has the advantages of simplicity and ease of fabrication, rapid detection, low cost of the apparatus and wide dynamic ranges.

CAS / MDL: 25322-68-3
研究领域: 材料科学 · 环境科学 · 电化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MOLECULES · 2023 ·Vol. 28 ·期 7 ·3262 · IF 4.6

TiO2-MXene/PEDOT:PSS Composite as a Novel Electrochemical Sensing Platform for Sensitive Detection of Baicalein

Shuya Xue,Min Shi,Jinye Wang,Jiapeng Li,Guanwei Peng,Jingkun Xu,Yansha Gao,Xuemin Duan,Limin Lu

In this work, TiO2-MXene/poly (3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) composite was utilized as an electrode material for the sensitive electrochemical detection of baicalein. The in-situ growth of TiO2nanoparticles on the surface of MXene nanosheets can effectively prevent their aggregation, thus presenting a significantly large specific surface area and abundant active sites. However, the partial oxidation of MXene after calcination could reduce its conductivity. To address this issue, herein, PEDOT:PSS films were introduced to disperse the TiO2-MXene materials. The uniform and dense films of PEDOT:PSS not only improved the conductivity and dispersion of TiO2-MXene but also enhanced its stability and electrocatalytic activity. With the advantages of a composite material, TiO2-MXene/PEDOT:PSS as an electrode material demonstrated excellent electrochemical sensing ability for baicalein determination, with a wide linear response ranging from 0.007 to 10.0 μM and a lower limit of detection of 2.33 nM. Furthermore, the prepared sensor displayed good repeatability, reproducibility, stability and selectivity, and presented satisfactory results for the determination of baicalein in human urine sample analysis.Keywords:TiO2-MXene;oxygen vacancy;PEDOT:PSS;baicalein;electrochemical sensor

CAS / MDL: 7558-79-4 7558-80-7
研究领域: 分析化学 · 材料科学 · 电化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2023 · IF 4.8

An ultrasensitive electrochemical sensor for detecting Cd(II) in aquatic products based on CS/COFs/PEDOT: PSS modified acupuncture needle electrode

Qi Guo,Yuhao Zhang,Luting Yan,Xiaoya Meng,Yue Wang,Hongguo Zhai,Xiaofeng Chen,Xia Sun,Yemin Guo,Yanyan Zhang

The use of low-cost working electrodes is of great importance for the development of sensor industrialization. Acupuncture needles electrode (ANE) was selected as working microelectrode, a sensor was designed based on poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT: PSS) and chitosan (CS) modified covalent organic frameworks (COFs) (CS/COFs) for detection of cadmium (Cd(II)). First, a mixture of PEDOT and PSS was electrodeposited on the surface of the acupuncture needles to synthesize a PEDOT: PSS as conductive polymeric film to support the electron transfer capability and enhance the conductive efficiency of the sensor. Then, CS/COFs was self-assembled and attached to the PEDOT: PSS/ANE surface by π-π stacking intermolecular interaction forces and the viscosity of CS, thus increasing the specific surface area of the electrode. Differential pulse anodic stripping voltammetry (DPASV) was used as the electrochemical method for detection of Cd(II). And the results indicated that the CS/COFs/PEDOT: PSS/ANE was linearly responsive in the range of 400 μg/L to 2400 μg/L, and the LOD was 13.8 ng/L for Cd(II). The constructed sensor also showed great selectivity, reproducibility, and stability. Additionally, the sensor demonstrated outstanding recovery in the detection of Cd(II) in real sample scallops. This sensing construction method based on acupuncture needles as working electrodes is of great significance to the development of sensor industrialization and aquatic product safety detection.

研究领域: 分析化学 · 环境科学 · 食品安全检测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。