JOURNAL OF HAZARDOUS MATERIALS
·
2020
·
IF 9.038
Fei Miao,Yanfeng Liu,Mingming Gao,Xin Yu,Pengwei Xiao,Mei Wang,Shuguang Wang,Xinhua Wang
Nowadays, microplastic pollution has been brought into focus for its hazards to aquatic life. However, researches on the electrocatalytic treatment for efficient degradation of microplastics are still insufficient. Herein, an electro-Fenton like (EF-like) technology based on TiO 2 /graphite (TiO 2 /C) cathode was put forward to degrade polyvinyl chloride (PVC), a typical microplastic in water. It exhibited a remarkable performance on PVC degradation via cathodic reduction dechlorination and hydroxyl radical (O H) oxidation simultaneously. Besides, the effects of reaction temperature and initial PVC concentration were investigated. Under optimal conditions, the dechlorination efficiency of PVC reached 75 % after potentiostatic electrolysis at -0.7 V vs. Ag/AgCl for 6 h. The intermediate products were explored during the degradation of PVC microplastics. The surface morphologies and molecular weight of PVC changed accordingly. Based on these results, a possible degradation process for PVC was proposed. This work demonstrated that such a heterogeneous EF-like technology using TiO 2 /C cathode was hopefully to provide an eco-friendly method for microplastic wastewater treatment.
研究领域:
环境科学
·
材料科学
✓ 已验证
DOI
PubMed
高影响因子
Materials
·
2022
·Vol. 15
·期 10
·3731
·
IF 3.748
Dan Yuan,Shungang Wan,Rurong Liu,Mengmeng Wang,Lei Sun
A novel material of self-shaped ZnO-embedded biomass carbon foam pellets (ZnO@BCFPs) was successfully synthesized and used as fluidized particle electrodes in three-dimensional (3D) electro-peroxone systems for metronidazole degradation. Compared with 3D and 2D + O3systems, the energy consumption was greatly reduced and the removal efficiencies of metronidazole were improved in the 3D + O3system. The degradation rate constants increased from 0.0369 min−1and 0.0337 min−1to 0.0553 min−1, respectively. The removal efficiencies of metronidazole and total organic carbon reached 100% and 50.5% within 60 min under optimal conditions. It indicated that adding ZnO@BCFPs particle electrodes was beneficial to simultaneous adsorption and degradation of metronidazole due to improving mass transfer of metronidazole and forming numerous tiny electrolytic cells. In addition, the process of metronidazole degradation in 3D electro-peroxone systems involved hydroxyethyl cleavage, hydroxylation, nitro-reduction, N-denitrification and ring-opening. The active species of ·OH and ·O2−played an important role. Furthermore, the acute toxicity LD50and the bioconcentration factor of intermediate products decreased with the increasing reaction time.Keywords:electro-peroxone process;particle electrode;metronidazole;degradation mechanism;detoxification
研究领域:
环境科学
·
化学工程
✓ 已验证
产品关联
DOI
PubMed
高影响因子
Environmental Science-Nano
·
2018
·Vol. 5
·期 8
·1834-1843
·
IF 6.087
Zehui Li,Yuheng Jiang,Chenming Liu,Zhuoya Wang,Zhiqin Cao,Yi Yuan,Mingjie Li,Yaling Wang,Daliang Fang,Zhuang Guo,Dongbin Wang,Guangjin Zhang,Jingkun Jiang
Hydrogen peroxide (H2O2) is a key species in many environmental processes such as the electro-Fenton system to remove organic pollutants in wastewater treatment. Traditional methods for measuring H2O2 are often complex and time-consuming. Due to their low cost and high catalytic activity, transition metals (TM) can be used as high-performance electrochemical sensing materials for detecting H2O2. However, the aggregation of metal atoms will severely limit their catalytic efficiency and exposure area. In this study, we explored a method to disperse TM homogeneously on a zeolitic imidazolate framework-8 (ZIF-8) derived nitrogen-doped carbon (N/C) nanoframework and used it as the electrocatalyst for detecting H2O2 in an electro-Fenton system. Cu and Mn were used as the examples. Benefitting from the homogeneously dispersed TM, the synthesized nanoframework with a low content of TM exhibits superior electrocatalytic activity and an anti-interference ability in detecting H2O2. It has a wide linear range (0.0005–50 mM for 1% Cu–N/C and 0.0001–50 mM for 1% Mn–N/C) and a low detection limit (0.047 μM for 1% Cu–N/C and 0.036 μM for 1% Mn–N/C). Using the synthesized nanoframework, a system for continuously detecting the H2O2 concentration in an electro-Fenton system in situ was presented. The reported method to fabricate such nanomaterials with a higher catalytic efficiency of TM has implications in other applications such as environmental treatment, catalysis, and energy conversion.
研究领域:
环境科学
·
材料科学
·
电化学
✓ 已验证
产品关联
DOI
高影响因子
Chemical Engineering and Processing-Process Intensification
·
2018
·
IF 2.826
Linchao Li,Huili Hu,Xiangguo Teng,Yuanchun Yu,Yongming Zhu,Xiaoqiang Su
The aim of this work is to prepare a hydrophobic cathode equipped with quite a few cracks for gas transfer, which can prepare H 2 O 2 in the course of electro-Fenton process. Scanning electron microscopy (SEM) and optical digital microscope are used to characterize the morphology of electrode, and an electrochemical workstation (CHI660e) is used to carry out all electrochemical studies with a conventional three-electrode system. The results demonstrate that the porous electrode is conducive to gas transmission with these cracks which can avoid the formation of bubbles. Additionally, the reaction is almost not affected by the content of dissolved oxygen and the gas flow with this structure. Under the conditions of 300 mA/cm 2 (current density), the H 2 O 2 concentration is up to 14.4 mmol/L after 30 min electrolysis with current efficiency beyond 90%. Furthermore, the cathode is successfully applied to electro-Fenton process which reduced catalyst loading. The results indicate that total degradation of MO is observed at the first 10 min, and 81% of TOC can be removed when the dosage of catalyst is 0.4 mmol/L within 60 min.
研究领域:
环境化学
·
电化学工程
·
水处理技术
·
反应器设计
·
污染物降解
✓ 已验证
DOI
高影响因子
CHEMOSPHERE
·
2020
·
IF 5.778
Huilan Lian,Ping Xiang,Yinghao Xue,Yuzhu Jiang,Mengying Li,Jingyu Mo
The significant removal efficiency of microcystis aeruginosa was presented using Pt/Ti anode and activated carbon fiber/nickel foam (ACF/Ni) cathode by addition of Fe 2+ slightly in a wide range of initial pH (3–9). Results showed that about 93% of the Microcystis aeruginosa cells were removed within 15 min for Pt/Ti-ACF/Ni–Fe 2+ system. Dosage of Fe 2+ , current density, and initial pH had remarkable effects on the removal efficiency of microcystis aeruginosa. The mechanism of algae removal in the Pt/Ti-ACF/Ni–Fe 2+ electrochemical system was revealed by the comparison between Pt/Ti-ACF/Ni–Fe 2+ process and classical Fenton process, the analysis on Microcystis aeruginosa and ACF/Ni by SEM, the specific surface area and pore size analysis of ACF, and the determination of UV 254 , OD 620 and microcystin-LR (MC-LR). Results showed that the main mechanism of this system was the electro-Fenton process, which was accompanied by electro-adsorption, electro-floatation, and electro-coagulation process. And the cooperation mechanism on the electrochemical removal system was further speculated. With the breakdown of algal cells during the electrolysis, the MC-LR and other substances released from the cells were effectively degraded. Besides, the new cathode exhibited favorable and stable reusability . This study built up a high-efficiency algae removal system, which broke through the limits of narrow working pH range and large consumption of exogenous chemicals in electro-Fenton process.
研究领域:
环境科学
·
水处理工程
✓ 已验证
DOI
高影响因子
Water
·
2022
·Vol. 14
·期 7
·1007
·
IF 3.53
Xudong Cheng,Xiaoping Zhang,Shaoqi Zhou,Lin Shi
For the treatment of 2-naphthol wastewater, the homogeneous electro-Fenton process was considered as an effective method but some disadvantages greatly restrict its application. The three-dimensional electro-Fenton (3D-EF) system using a nano zero-valent iron-supported biochar (NZVIs-BC) particle electrode and a Cu-supported stainless steel electrode (Cu-SSE) was proposed to avoid the disadvantages of the homogeneous electro-Fenton. In this work, the 3D-EF system was developed, which consisted of a Cu-SSE (cathode), a graphite rod (anode) and a NZVIs-BC particle electrode. The effect of the ratio of ferrous sulfate heptahydrate (FS) to rice straw (RS), CuSO4•5H2O amount, initial pH of 2-naphthol wastewater and current intensity (the output current of the power supply) on the removal rate of 2-naphthol were investigated. It is noteworthy that more than 98.36% of the 2-naphthol in aqueous solution was removed by the 3D-EF system, and only about 60.09% of 2-naphthol was removed by the homogeneous electro-Fenton system. Furthermore, naphthalene, benzoic acid, β-naphthoquinone, 1, 2-naphthalenedione, phenol and aromatic hydrocarbon were the main degradation products of 2-naphthol by the 3D-EF system; the toxicity of 2-naphthol wastewater was also greatly reduced.Keywords:electro-Fenton;Cu-supported stainless steel electrode;nano zero-valent iron-supported biochar;2-naphthol wastewater
研究领域:
环境科学
·
化学工程
✓ 已验证
产品关联
DOI
高影响因子