文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
痰液
Frontiers in Bioengineering and Biotechnology · 2023 · IF 5.7

Au nanorod assembly for sensitive SERS detection of airway inflammatory factors in sputum

An-qi Yang,Wentong Zheng,Xiaoyang Chen,Jiayin Wang,Shuang Zhou,Hongzhi Gao

In this paper, we demonstrate a surface-enhanced Raman spectroscopy (SERS) biosensor based on the self-assembly of gold nanorods (AuNRs) for the specific detection of airway inflammatory factors in diluted sputum. The AuNR surface was modified with an antibody that was able to specifically recognize an airway inflammatory factor, interleukin-5 (IL-5), so that a end-to-end self-assembly system could be obtained, resulting in an order of magnitude amplification of the Raman signal and greatly improved sensitivity. Meanwhile, the outer layer of the biosensor was coated with silicon dioxide, which improved the stability of the system and facilitated its future applications. When the detected concentration was in the range of 0.1–50 pg/mL, the SERS signal generated by the sensor showed a good linear relationship with the IL-5 concentration. Moreover, it had satisfactory performance in diluted sputum and clinical subjects with asthma, which could achieve sensitive detection of the airway inflammatory factor IL-5. Overall, the developed biosensor based on the SERS effect exhibited the advantages of rapid and sensitive detecting performance, which is suitable for monitoring airway inflammatory factors in sputum.

研究领域: 纳米技术 · 生物医学工程 · 分析化学 · 医学诊断
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MACROMOLECULAR BIOSCIENCE · 2023 · IF 4.6

Microinjection Molded Biopolymeric Airway Stent with Antibacterial and Anti-Hyperplastic Properties

Jiahui Dong,Yahua Li,Xiaofeng Wang,Yajing Liu,Kewei Ren,Xuedi Liu,Han Zhang,Zongming Li,Xinwei Han,Hiroshi Uyama,Qian Li

Central airway stenosis is a condition that the diameter of the trachea or main bronchus shrinkage is caused by external compression or internal tissue hyperplasia, which can cause difficulty breathing, asphyxia, and even death. Airway stenting is an easy way to restore the patency of the central airway, but airway stents commonly used in clinical practice can lead to complications such as mucus plugging, bacterial infection, and granulation tissue hyperplasia. Moreover, the non-degradable characteristic makes it requires a second operation to remove, which has the potential to cause tissue damage. In this study, a biodegradable airway stent is fabricated by microinjection molding using the bioelastomer of poly (L-lactide- co - ε -caprolactone) as the matrix material. The airway stent has excellent mechanical properties and an appropriate degradation rate. The hydrophilic surface of the airway stent can inhibit mucus plugging. The loading of silver nanoparticles and cisplatin endows the stent with antibacterial and anti-hyperplastic functions. In vitro and in vivo experiments demonstrate that this study provides an antibacterial and anti-hyperplastic biodegradable airway stent with elastic properties to avoid secondary removal operation and reduce complications associated with mucus plugging, bacterial infection, and granulation tissue hyperplasia.

CAS / MDL: 14913-33-8
研究领域: 生物医学工程 · 材料科学 · 组织工程 · 药物递送系统
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。