文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
硬段长度
International Journal of Polymeric Materials and Polymeric Biomaterials · 2017 · IF 1.515

Influence of well-defined hard segment length on the properties of medical segmented polyesterurethanes based on poly(ε-caprolactone-co-L-lactide) and aliphatic urethane diisocyanates

Qi Jia,Yiran Xia,Shengnan Yin,Zhaosheng Hou,Ruxia Wu

This work describes the preparation, characterization, mechanical properties, in vitro degradability, and cytocompatibility of two aliphatic segmented polyesterurethanes (SPEU-II, SPEU-III) based on poly(ε-caprolactone-co-L-lactide) and aliphatic urethane diisocyanate chain extenders. Two novel chain extenders containing two and four urethane groups, respectively, were synthesized and used in SPEU formulation. The influences of well-defined hard segment length on the degradability and mechanical properties of SPEU films were researched. The results of differential scanning calorimeter and X-ray powder diffraction showed that the long well-defined hard segments improved the phase separation of soft and hard segments, which led to satisfactory mechanical properties of SPEU films (ultimate stress: 24.8–35.4 MPa; strain at break: 601–669%). And the initial modulus increased from 31.9 MPa (SPEU-II) to 41.7 MPa (SPEU-III) with the increasing length of hard segments. SPEU-III with longer well-defined hard segment containing more urethane groups exhibited slower hydrolytic degradation rate (∼67 days) and lower water absorption (∼4 wt%) than SPEU-II. The results could be due to the formation of more hydrogen bonds among the hard segments and between the soft and hard segments, which strengthened the interchain attraction and gave a more compact network structure. The SPEU films showed similar thermostability, indicating that the length of hard segments marginally affects the thermostability. Cytotoxicity test of film extracts was conducted using L929 mouse fibroblasts, and the relative growth rate exceeded 90% after incubation for 24, 48, and 72 h, showing excellent cytocompatibility.

CAS / MDL: 110-63-4
研究领域: 生物材料学 · 医学工程 · 高分子化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。