文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
磁珠-SELEX
SENSORS AND ACTUATORS B-CHEMICAL · 2024 · IF 8

In vitro selection and engineering azithromycin-specific aptamers and construction of a ratiometric fluorescent aptasensor for sensitive detection of azithromycin

Tianyu Huang,Xin Chen,Jinri Chen,Yuting Zhang,Xiaoli Wang,Zhimeng Wu,Nandi Zhou

Azithromycin can effectively inhibit bacterial protein synthesis and reduce biofilm formation and quorum sensing, and thus has been preferentially used in the treatment of various infections. However, azithromycin is also among the most highly concentrated antibiotics present in wastewater due to the inappropriate use and treatment. In order to sensitively and rapidly monitor the azithromycin residues, aptamers specific to azithromycin were selected through 12 rounds of screening by using magnetic beads-SELEX (MB-SELEX). The screened aptamers were assessed for their affinity and specificity using fluorescent assay. Apt3 emerged as the optimal candidate aptamer with the dissociation constant (K d ) of 235.07 nM. After secondary structure analysis and molecular docking, Apt3 was systematically truncated and subjected to single-base mutations. The optimal aptamer Apt3–27 T was identified, exhibiting the K d value of 215.84 nM and the improved specificity compared to the original aptamer. Then Apt3–27 T was utilized to construct a ratiometric fluorescent aptasensor, which exhibited the linear dynamic range of 25–400 nM and low detection limit of 9.78 nM. More importantly, the ratiometric fluorescence mechanism further improved the specificity of the biosensor, which finally can discriminate azithromycin from structurally similar erythromycin. Evaluation experiments using actual samples spiked with azithromycin showed the recovery ranging from 97.1% to 106% and the relative standard deviation ranging from 4.29% to 8.61%. The screened aptamer and constructed aptasensor offer the advantages of high affinity, high effectiveness and ease of use in actual sample detection, thereby displaying promising applications in the monitoring of azithromycin residues.

CAS / MDL: 107-22-2
研究领域: 分析化学 · 环境科学 · 生物传感器 · 药物分析
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。