文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

3 项

设置提升方向
离子色谱
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY · 2015 ·Vol. 43 ·期 10 ·1569-1572 · IF 0.754

Development and Evaluation of On-line Eluent Generator

Ming-Yan LUO,Bei LÜ,Guo-Bin SHEN,Fei-Fang ZHANG,Bing-Cheng YANG

Electrodialytic eluent generator, one of the key components of ion chromatography system, was fabricated and evaluated. The data achieved indicated that its performance could be comparable to that of commercial one. The maximal operation pressure was over 20 MPa, the generated KOH concentration was up to 100 mM, and the designed usage lifetime was about 354 day (take 8 h working time per day). This device will be helpful to the improvement of domestic instruments of ion chromatography.

研究领域: 分析化学 · 仪器科学与技术 · 分离科学 · 离子色谱技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHINESE JOURNAL OF CHEMISTRY · 2011 ·Vol. 29 ·期 4 ·778-782 · IF 0.773

Determination of Glycolate Acid, Mono- and Dichloroacetic Acids in Synthetical Betaine by Anion-exchange Chromatography

Haining Shi,Zonghua Wang,Hui Wang,Rui Zhao,Mingyu Ding

An anion-exchange chromatography method combined solid phase extraction (SPE) was developed for the simultaneous analysis of glycolate acid (GL), monochloroacetic acid (MCA) and dichloroacetic acid (DCA) in synthetical betaine products. The analytes and unknown anionic impurities were well separated on a Metrosep A supp5 anion-exchange column (150 mm×4 mm) with 2.0 mmol/L Na 2 CO 3 +2.0 mmol/L NaHCO 3 solution as eluent. Suppressed conductivity detection was used. A strong cation exchange (SCX) solid phase extraction (SPE) cartridge was used to reduce the concentration of matrix betaine and a Cleanert IC-Ag pretreatment cartridge was used to remove high Cl − concentration. The detection limits of GL, MCA and DCA were 0.09, 0.017 and 0.05 µg/L, respectively. The relative standard deviations (RSDs) of the retention times and peak areas were less than 0.09% and 0.49%, respectively. The recoveries of the three analytes were between 90.6% and 100.8%. The analytical results showed that GL and DCA were present in high concentration and no MCA was found when the proposed ion chromatography method was applied to three synthetical betaine samples. The proposed method is simple, sensitive and timesaving, and is also suitable for routine analysis in quality control of synthetical betaine products.

研究领域: 分析化学 · 药物质量控制 · 分离科学 · 环境分析 · 食品化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
CHINESE CHEMICAL LETTERS · 2015 ·Vol. 26 ·期 8 ·1026-1030 · IF 1.587

Iodide analysis by ion chromatography on a new stationary phase of polystyrene-divinylbenzene agglomerated with polymerized-epichlorohydrin-dimethylamine

Mu-Hua Wang,Zhong-Ping Huang,Jun-Wei Liu,Jie He,Jia-Jie Zhang,Yan Zhu

A new stationary phase for iodide ion analysis has been developed. The cationic polymer-epichlorohydrin-dimethylamine (PEPI-DMA) was served as modifier in synthesizing polyelectrolyte sorbents and the macroporous polystyrene-divinylbenzene (PS-DVB) resin was used as support. The positively charged polymer (PEPI-DMA) was electrostatically bonded to a negatively charged particle (PS-DVB sulfonated). The new stationary phase was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR), elemental analysis, chemical adsorption and desorption measurements. The chromatographic evaluation of the new stationary phase was performed using various anions with a conductivity detector. The new stationary phase was also applied to the determination of iodide directly with a DC amperometric detector using a platinum working electrode and an Ag/AgCl reference electrode. The chromatographic conditions were optimized and the eluent solution contained 5   mmol/L HNO 3 and 15   mmol/L NaNO 3 at a flow rate of 1.0   mL/min and column temperature of 30   °C. The applied voltage of the DC amperometric detector was 0.9   V. Under the optimum conditions, the linear range of the method was 0.2–50   mg/L for iodide ion with a correlation coefficient of 0.9990. The detection limit was 0.05   mg/L (calculated at S/N   =   3) and the relative standard deviations (RSD, n   =   6) were all less than 1% for retention time, peak area and peak height. This method was also utilized for the determination of iodide ions in samples of povidone iodine solution and kelp samples with satisfactory results.

研究领域: 分析化学 · 环境化学 · 分离科学 · 离子色谱 · 电分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。