Antibody-drug conjugate (ADC) plays a crucial role in the treatment of various diseases and intravenous injection is the primary administration route for ADCs due to its high bioavailability. However, this method requires drug preparation and dilution, which can compromise the stability of the solution and increase the risk of aggregation as excipient concentrations are reduced during dilution. Antibody drug dosing is often based on patient body weight and typically diluted in either 0.9% (w/v) sodium chloride or 5% (w/v) dextrose injections. Variations in patient body weight lead to differences in the final concentrations of both the drug and excipients, affecting stability. In this study, we examined the stability of intravenous dilutions for patients with varying body weights using trastuzumab and ado-trastuzumab emtansine ADCs. Analytical techniques including size-exclusion chromatography (SEC), fluid imaging microscopy (FIM), bicinchoninic acid (BCA) assay, and turbidity testing were employed to assess monomer, oligomer, and aggregate levels before and after dilution. Machine learning was applied to distinguish the morphology of sub-visible particles. Our findings reveal that weight-based dosing leads to significant stability differences in intravenous preparations. This study offers important insights into the formulation stability of biopharmaceuticals and their clinical use.
A highly purified and bioactive immunoglobulin G monoclonal antibody against receptor-binding domain of SARS-CoV-2 (RBD-IgG-MAb) has been accurately quantified by amino acid determination using isotope dilution liquid chromatography–mass spectrometry. Absolute quantification of RBD-IgG-MAb was achieved by averaging 4 amino acid certified reference materials, which allows the quantitative value (66.1 ± 5.8 μg/L) to be traced to SI unit (mol). Afterwards, the RBD-IgG-MAb was employed as control and calibration compound for the development of a point-of-care testing (POCT) system based on colloidal gold lateral flow immunoassay, which aimed to rapidly and accurately detect the level of protective RBD-IgG after vaccination. Under the detection parameters, a sigmoidal curve has been plotted between signal intensity and the logarithmic concentration for quantitative detection with the limit of detection of about 0.39 μg/mL. The relative standard deviations of intra-assay and inter-assay were lower than 2.3% and 14%, and the recoveries ranged from 87 to 100%, respectively. Fingertip blood samples from 37 volunteers after vaccination were analyzed by the POCT system; results showed that levels of RBD-IgG in 33 out of 37 samples ranged from 0.45 to 2.46 μg/mL with the average level of 0.91 μg/mL. The developed POCT system has been successfully established with the quantity-traceability RBD-IgG-MAb as control and calibration compound, and the scientific contribution of this work can be promoted to other areas. Graphical Abstract
Accurate measurement of serum glycocholic acid (GCA) is crucial for evaluating the activity of chronic hepatitis. Moreover, GCA is a novel identified biomarker for hepatocellular carcinoma. Although some laboratories have used the liquid chromatography-tandem mass spectrometry (LC–MS/MS) method to measure GCA in recent years, the problem of potential interference of GCA analogues has not been solved well yet. Neither reference measurement procedures nor reference materials for GCA have been listed in the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. For standardization of GCA, it is urgent to establish a candidate measurement procedure for GCA. In this study, a candidate reference measurement procedure for the quantification of GCA in human serum based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS) by a two-step sample pretreatment of protein precipitation and MAX solid-phase extraction was developed and validated. GCA can be completely separated from its structural analogues with gradient elution in 9 min compared with short time gradients published in previous literature by Huang’s group. Method validation indicated perfect quantitation precision with intra-day and inter-day values that were ≤1.30% and ≤1.80%, respectively. The method showed excellent linearity with high regression coefficients ( R 2 > 0.999) over a range of 0.92 ng/g–38.38 μg/g and perfect recoveries at three spiked levels (99.87–100.43%). No interference, matrix effect, and carryover were observed. Moreover, the cRMP was successfully applied to measure GCA in serum samples and compared with two immunoassays in a clinical laboratory. As a candidate reference method, this method can promote a GCA standardization program. Graphical Abstract