文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

2 项

设置提升方向
米拉贝隆
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS · 2023 · IF 3.4

Simultaneous quantification of mirabegron and vibegron in human plasma by HPLC-MS/MS and its application in the clinical determination in patients with tumors associated with overactive bladder

Yutao Lou,Mengting Cheng,Qin Cao,Kening Li,Hui Qin,Meihua Bao,Yuan Zhang,Sisi Lin,Yiwen Zhang

Mirabegron and vibegron, both newly identified beta-3 adrenergic agonists, have significantly improved the quality of life for patients suffering from overactive bladder. In order to comprehensively assess the plasma exposure levels of these agents, the development of a rapid and highly sensitive bioanalytical method becomes imperative. The primary objective of this study was to establish a robust high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for the concurrent quantification of mirabegron and vibegron in human plasma. The analytes were extracted from a 100   μL plasma sample through protein precipitation, employing 300   μL of methanol. Subsequently, samples underwent separation and quantification using a Waters XBridge C 18 column (2.1 × 100   mm, 3.5   µm), with a mobile phase consisting of 0.1% formic acid in water and 0.1% formic acid in acetonitrile. The mass analysis was conducted using positive electrospray ionization (ESI+) operated in a multiple reaction monitoring (MRM) mode. The proposed method was meticulously validated in accordance with the guidelines set forth by the U.S. Food and Drug Administration (FDA) for bioanalytical method validation. The regression equations demonstrated exceptional linearity for both mirabegron (r² ≥ 0.994) and vibegron (r² ≥ 0.996) across the concentration range of 0.5 – 200   ng/mL. Furthermore, the assay exhibited accuracy (inter-day relative error ≤ 6.90%) and precision (inter-day coefficient of variation ≤ 8.88%). The average recoveries of the analytes were found to range from 81.94% to 102.02%, with mean matrix effects falling within the range of 89.77% to 110.58%. As a result, this method was deemed highly suitable for the precise determination of the concentrations of both mirabegron and vibegron in the context of therapeutic drug monitoring and bioequivalence studies.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2024 ·Vol. 191 ·期 8 ·1-11 · IF 5.3

Aptasensor based on gold nanostructure-decorated 2D Cu metal–organic framework nanosheets for highly sensitive and specific electrochemical lipopolysaccharide detection

Tong Yanli,Chen Meng,Huang Xing,Xu Yuzhi,Zhang Lang,Yu Zhenning,Liu Si-Yang,Dai Zong

Detecting lipopolysaccharide (LPS) using electrochemical methods is significant because of their exceptional sensitivity, simplicity, and user-friendliness. Two-dimensional metal–organic framework (2D-MOF) that merges the benefits of MOF and 2D nanostructure has exhibited remarkable performance in constructing electrochemical sensors, notably surpassing traditional 3D-MOFs. In this study, Cu[tetrakis(4-carboxylphenyl)porphyrin] (Cu-TCPP) and Cu(tetrahydroxyquinone) (Cu-THQ) 2D nanosheets were synthesized and applied on a glassy carbon electrode (GCE). The 2D-MOF nanosheets, which serve as supporting layers, exhibit improved electron transfer and electronic conductivity characteristics. Subsequently, the modified electrode was subjected to electrodeposition with Au nanostructures, resulting in the formation of Au/Cu-TCPP/GCE and Au/Cu-THQ/GCE. Notably, the Au/Cu-THQ/GCE demonstrated superior electrochemical activity because of the 2D morphology, redox ligand, dense Cu sites, and improved deposition of flower-like Au nanostructure based on Cu-THQ. The electron transfer specific surface area was increased by the improved deposition of Au nanostructures, which facilitates enriched binding of LPS aptamer and significantly improved the detection performance of Apt/Au/Cu-THQ/GCE electrochemical aptasensor. The limit of detection for LPS reached 0.15 fg/mL with a linear range of 1 fg/mL − 100 pg/mL. The proposed aptasensor demonstrated the ability to detect LPS in serum samples with satisfactory accuracy, indicating significant potential for clinical diagnosis. Graphical Abstract

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。