文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

4 项

设置提升方向
缓激肽
Nature Communications · 2023 ·Vol. 14 ·期 1 ·1-17 · IF 16.6

Reduced hepatic bradykinin degradation accounts for cold-induced BAT thermogenesis and WAT browning in male mice

Xiao Fei,Jiang Haizhou,Li Zi,Jiang Xiaoxue,Chen Shanghai,Niu Yuguo,Yin Hanrui,Shu Yousheng,Peng Bo,Lu Wei,Li Xiaoying,Li Zhigang,Lan Shujue,Xu Xiaoyan,Guo Feifan

An important role for liver in the regulation of adipose tissue thermogenesis upon cold exposure has been suggested; however, the underlying mechanisms remain incompletely defined. Here, we identify elevated serum bradykinin levels in response to acute cold exposure in male mice. A bolus of anti-bradykinin antibodies reduces body temperature during acute cold exposure, whereas bradykinin has the opposite effect. We demonstrate that bradykinin induces brown adipose tissue thermogenesis and white adipose tissue browning, and bradykinin increases uncoupling protein 1 (UCP1) expression in adipose tissue. The bradykinin B2 receptor (B2R), adrenergic signaling and nitric oxide signaling are involved in regulating bradykinin-increased UCP1 expression. Moreover, acute cold exposure inhibits hepatic prolyl endopeptidase (PREP) activity, causing reduced liver bradykinin degradation and increased serum bradykinin levels. Finally, by blocking the breakdown of bradykinin, angiotensin-converting enzyme inhibitors (ACEIs) increase serum bradykinin levels and induce brown adipose tissue thermogenesis and white adipose tissue browning via B2R. Collectively, our data provide new insights into the mechanisms underlying organ crosstalk in whole-body physiology control during cold exposure and also suggest bradykinin as a possible anti-obesity target.

CAS / MDL: 57-66-9
研究领域: 生理学 · 内分泌学 · 代谢 · 药理学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Small · 2016 ·Vol. 13 ·期 3 ·1602494 · IF 8.315

ATP/pH Dual Responsive Nanoparticle with d-[des-Arg10]Kallidin Mediated Efficient In Vivo Targeting Drug Delivery

Yu Zhang,Yifei Lu,Feng Wang,Sai An,Yujie Zhang,Tao Sun,Jianhua Zhu,Chen Jiang

Inflammation has been reported as one significant hallmark of breast cancer in relation to tumor development, metastasis, and invasion. The bradykinin receptor 1 (B1R) is highly expressed on inflammatory breast tumor cells thus providing a promising targeting site for tumor recognition and sufficient receptor mediated endocytosis. In this study, the authors evaluate the targeting efficiency of l -form and d -form [des-Arg 10 ]kallidin both in vitro and in vivo. To further improve the drug delivery efficiency, the authors establish a dandelion like nanoparticle by combining the polymeric drug conjugates and aptamer complex together. The doxorubicin conjugated polymer is complexed with adenosine-5′-triphosphate (ATP) sensitive hybridized aptamer in self-assembly process by intercalating into the double strand scaffolds. The acid labile conjugating bond and ATP sensitive aptamer endow the nanoparticle with dual responsiveness to intracellular milieu, thus triggering a quick drug release in tumor cells. Remarkable therapeutic effects and tuned in vivo pharmacokinetics profiles are shown by the aptamer complexed drug conjugates nanoparticle with B1R active targeting modification. Therefore the strategies of B1R targeting and ATP/pH dual-responsiveness nanoparticle help achieve enhanced drug accumulation within tumor cells and efficient chemotherapy for breast cancer.

CAS / MDL: 2177-63-1
研究领域: 药学 · 纳米技术 · 癌症研究 · 药物递送系统
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF SEPARATION SCIENCE · 2011 ·Vol. 34 ·期 22 ·3123-3130 · IF 2.631

Grafting of silica with a hydrophilic triol acrylamide polymer via surface-initiated “grafting from” method for hydrophilic-interaction chromatography

Xi-Tian Peng,Bi-Feng Yuan,Yu-Qi Feng

A novel hydrophilic polymer-coated silica sorbent has been prepared using the radical “grafting from” polymerization method through surface-bound azo initiators for hydrophilic-interaction chromatography (HILIC). The azo groups were introduced to the surface of silica gel through the reaction with amino groups on the surface of silica gel with 4,4′-azobis(4-cyanopentanoic acid chloride) (ACVC). The resultant azo-immobilized silica gel served as surface initiator to polymerize hydrophilic triol acrylamide monomer N -acryloyltris(hydroxymethyl) aminomethane (NA) in methanol to get hydrophilic polymer-coated silica sorbent. The obtained poly(NA)-coated silica (pNA-sil) was characterized by Fourier transform infrared spectroscopy (FT-IR), elemental analysis (EA), and nitrogen sorption porosimetry (NSP). Then the pNA-sil was packed into the stainless-steel column and evaluated in high-performance liquid chromatography (HPLC). Good chromatographic performance for the separation of peptides and nucleosides was obtained under HILIC mode. The results indicated that the pNA-sil stationary phase behaved as mixed-mode retention mechanisms of hydrophilic and ionic interactions. Furthermore, the pNA-sil phase was used to separate tryptic digest of β-casein and our results showed that more than 12 peptides peaks were resolved and well distributed within the elution window. Finally, the pNA-sil stationary phase was demonstrated to possess remarkable reproducibility and stability. Taken together, the pNA-sil stationary phase prepared in the current study offers a potential application in proteomics study.

研究领域: 分析化学 · 材料科学 · 色谱技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2023 · IF 7.4

SR-Unet: A Super-Resolution Algorithm for Ion Trap Mass Spectrometers Based on the Deep Neural Network

Jiawen Ai,Weize Zhao,Quan Yu,Xiang Qian,Jianhua Zhou,Xinming Huo,Fei Tang

The mass spectrometer is an important tool for modern chemical analysis and detection. Especially, the emergence of miniature mass spectrometers has provided new tools for field analysis and detection. The resolution of a mass spectrometer reflects the ability of the instrument to discriminate between adjacent mass-to-charge ratio ions, and the higher the resolution, the better the discrimination of complex mixtures. Quadrupole ion traps are generally considered as a low-resolution mass spectrometry method, but they have gained wide attention and development in recent years because of their suitability for miniaturization and high qualitative capability. For an ion trap mass spectrometer, the mass sensitivity and resolution can be mutually constrained and need to be balanced by setting an appropriate scanning speed. In this study, a super-resolution U-net algorithm (SR-Unet) is proposed for ion trap mass spectrometry, which can estimate the possible ions from the overlapping ion peaks of low-resolution spectra and improve the equivalent resolution while ensuring sufficient sensitivity and analysis speed of the instrument. By determining the mass spectra of a linear ion trap mass spectrometer (LTQ XL) in Turbo and Normal scan modes, the same unit mass resolution as that at a scan speed of 16,667 Da/s was successfully obtained at 125,000 Da/s. Also, the experiments demonstrated that the algorithm is capable of the mass-to-charge ratio and instrument migration. SR-Unet can be migrated and applied to a miniature mass spectrometer for cruise detection of volatile organic compounds (VOCs), and the identification of VOC species in Photochemical Assessment Monitoring Stations (PAMS) was improved from 31 to 50 species with the same monitoring and analysis speed requirement. Further, super-unit mass resolution peptide detection was achieved on a miniature mass spectrometer with the help of the SR-Unet algorithm, which reduced the full width at half-maxima (FWHM) of bradykinin divalent ions (m/z 531) from 0.35 to 0.15 Da at a scan speed of 375 Da/s and improved the equivalent resolution to 3540. The proposed method provides a new idea to enhance the field mixture detection capability of miniature ion trap mass spectrometers.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。