文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
缺陷尺寸
JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS · 2022 · IF 5.582

Cavitation/fracture transition of soft materials

Yimou Fu,Tenghao Yin,Shaoxing Qu,Wei Yang

A defect in soft materials expands rapidly under a critical hydrostatic tension, causing cavitation or fracture. The mechanical properties of the material and the size of the defect have decisive influence on the failure mechanism. As different modes of material failure, the transition between cavitation and fracture is still elusive. Combining the Griffith's fracture criterion and finite deformation theory, we hereby obtained the critical initial defect size of cavitation/fracture transition. In the experiments, a cavitation rheology device was built to measure the failure mode of polyacrylamide hydrogels by inserting needles with various sizes. By observing the surface roughness and measuring critical expansion pressure of the bubble, we verified that the transition size is controlled by fractocohesive length Γ / W f , which can be orders of magnitude smaller than elasto-adhesive length Γ / E . The present work reveals the transition mechanism between cavitation and fracture, quantifies the transition size, and provides a promising route to predict the failure behaviors of highly stretchable materials.

研究领域: 材料科学 · 生物力学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
THEORETICAL AND APPLIED FRACTURE MECHANICS · 2020 · IF 3.021

A quantitative study of flaw/strength response in ultra-high temperature ceramics based on femtosecond laser method

Anzhe Wang,Xinyuan Zhao,Mingxu Huang,Zhen Zhang,Lishuai Xie

In this paper, a systematic study on the effect of flaws on flexural strength of ultra-high temperature ceramics (UHTCs) was carried out by using three typical materials (i.e., ZrB 2 , ZrB 2 -SiC and ZrB 2 -SiC-G ceramics) containing micro-sized flaws with controllable sizes, shapes as well as orientations. Depending on the flaw sizes and orientations, different fracture modes were analyzed by SEM observation and theoretical calculation. Based on Emmerich’s hole/strength model and the maximum strain-energy release-rate mixed-mode fracture criterion, a universal flaw/strength model was developed to describe the flexural strength of flawed UHTCs after taking both material properties and flaw’s geometries into account, and compared well with the experimental data in both mode I and mixed-mode conditions. Prediction results of the proposed model have further verified that substantially consistent with the flexural strength reports of UHTCs in the literature as well as the theoretical strengths calculated from the elastic modulus, which means that the proposed model has a great potential in guiding the design of high-strength ceramics in full-scale (from atomic-scale to macro-scale).

CAS / MDL: 409-21-2
研究领域: 材料科学 · 力学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
CERAMICS INTERNATIONAL · 2018 · IF 3.057

Accurate evaluation of critical flaw size in structural ceramics via femtosecond laser

Anzhe Wang,Bin Du,Ping Hu,Xinghong Zhang

Critical flaw size of structural ceramics is generally less than 100 μm and is therefore too small to be reliably evaluated. In this study, micro-sized flaws (as small as 10 µm) were introduced via femtosecond laser for the first time, and the critical flaw sizes of ZrB 2 and ZrB 2 -SiC-Graphite ceramics (12.9 µm and 36.1 µm, respectively) were accurately evaluated by linear extrapolation in double logarithmic coordinates. The critical flaw sizes calculated from the indentation fracture toughness (14.3 µm and 34.3 µm for ZrB 2 and ZrB 2 -SiC-Graphite ceramics, respectively) agreed well with the experimental results, while significant overestimation would occur by using fracture toughness values measured by means of single-edge notched beam, single-edge V-notched beam and single-edge precracked beam methods, which was mainly due to the fact that the notches in these three tests had the depth scale nearly two orders of magnitude higher than those of the inherent flaws.

CAS / MDL: 409-21-2
研究领域: 材料科学 · 工程学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。