文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
聚芦丁
ELECTROANALYSIS · 2024 · IF 2.7

Determination of Fluoroquinolones Antibiotics in Water by Polyrutin Film-Modified Electrochemical Sensor

Jiao Qiu,Wanglei Gou,Wen Chen,JingFeng Gao

This study is aimed at the determination of a new pollutant, fluoroquinolones antibiotics (FQs). Taking ciprofloxacin (CIP) as the research representative, rutin polymer film-modified sensor polyrutin modified glass carbon electrode (PRT/GCE) was prepared by electropolymerization, and a new analytical method for the determination of FQs was established, which is environmentally friendly, simple, efficient, and economical. The topography, elemental composition, and electrochemical behavior of the sensor were investigated using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The results showed that the linear range of the PRT/GCE sensor used for CIP was 0.8–50 μM, the detection limit was 0.050 μM, and the recovery rate was 94.9%–104%. In addition, when it was used to detect norfloxacin (NOR), enrofloxacin (ENR), pefloxacin (PEF), and rofloxacin (FLE) in FQs, the sensor similarly exhibited a broad linear range; its corresponding detection limits were 0.078, 0.16, 0.088, and 0.12 μM, respectively. The PRT/GCE sensor had a high active area, good catalytic performance for FQs, simple preparation, stable performance, and reusability. It has potential application value for routine determination of fluoroquinolones in real water.

研究领域: 环境科学 · 分析化学 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS · 2022 · IF 5.518

A polyrutin/AgNPs coated GCE for simultaneous anodic stripping voltammetric determination of Pb(II) and Cd(II)ions in environmental samples

Zhou Liuzhu,Sankar Sekar,Jin Chen,Sejoon Lee,Deuk Young Kim,Ramalingam Manikandan

Here, we report a simple one-step preparation of polyrutin/silver nanoparticles (AgNPs) on the glassy carbon electrode (GCE) surface using an electrochemical deposition/polymerization technique. As prepared polyrutin/AgNPs/GCE has been characterized by different techniques such as SEM with elemental morphing, TEM with EDAX , XRD , ATR-IR to confirm the materials formation. Further, electrochemical behavior of the polyrutin/AgNPs/GCE was tested by cyclic voltammetry , EIS and differential pulse voltammetric techniques. As fabricated polyrutin/AgNPs/GCE was used for simultaneous detection of Pb(II) and Cd(II)ions using anodic stripping voltammetric techniques and stripping analysis of Pb(II) and Cd(II)ions analytical parameters like pH, preconcentration time were studied. The polyrutin/AgNPs/GCE has showed a linear concentration range from 29 nM to 140 nM and 57–203 nM with detection limit of 3 nM and 10 nM for Pb(II) Cd(II)ions respectively. Further, the modified electrode was tested towards detection of these heavy metal ions in different environmental samples and the found excellent recovery results were further correlated with ICP-MS results.

研究领域: 环境科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ELECTROANALYSIS · 2025 ·Vol. 37 ·期 1 ·e12006 · IF 2.3

Determination of Fluoroquinolones Antibiotics in Water by Polyrutin Film-Modified Electrochemical Sensor

Jiao Qiu,Wanglei Gou,Wen Chen,JingFeng Gao

This study is aimed at the determination of a new pollutant, fluoroquinolones antibiotics (FQs). Taking ciprofloxacin (CIP) as the research representative, rutin polymer film-modified sensor polyrutin modified glass carbon electrode (PRT/GCE) was prepared by electropolymerization, and a new analytical method for the determination of FQs was established, which is environmentally friendly, simple, efficient, and economical. The topography, elemental composition, and electrochemical behavior of the sensor were investigated using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The results showed that the linear range of the PRT/GCE sensor used for CIP was 0.8–50 μM, the detection limit was 0.050 μM, and the recovery rate was 94.9%–104%. In addition, when it was used to detect norfloxacin (NOR), enrofloxacin (ENR), pefloxacin (PEF), and rofloxacin (FLE) in FQs, the sensor similarly exhibited a broad linear range; its corresponding detection limits were 0.078, 0.16, 0.088, and 0.12 μM, respectively. The PRT/GCE sensor had a high active area, good catalytic performance for FQs, simple preparation, stable performance, and reusability. It has potential application value for routine determination of fluoroquinolones in real water.

CAS / MDL: 79-57-2
研究领域: 环境科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。