文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

5 项

设置提升方向
肌红蛋白
RSC Advances · 2018 ·Vol. 8 ·期 66 ·38003-38012 · IF 2.936

Construction of myoglobin–amphiphilic alginate caprylamide–graphene composite modified electrode for the direct electron transfer between redox proteins and electrode and electrocatalysis of myoglobin

Xiuqiong Chen,Huiqiong Yan,Wei Sun,Guangying Chen,Changjiang Yu,Wen Feng,Qiang Lin

To achieve the dispersion of the hydrophobic graphene (GR), the amphiphilic alginate caprylamide (ACA) was synthesized to fabricate electroactive Nafion/Mb–ACA–GR/CILE for the accurate determination of trichloroacetic acid (TCA). SEM observation, FT-IR and UV-Vis spectroscopic analysis indicated that ACA could tightly immobilize Mb and GR on the electrode surface by constructing biointerfaces, which not only provided Mb a suitable microenvironment to maintain its biological activity, but also shortened the distances between the active centers of Mb with carbon ionic liquid electrode (CILE), thus promoting the electron transfer rate. The electrochemical characterization of Nafion/Mb–ACA–GR/CILE showed that the direct electron transfer of Mb was realized on the modified electrode, which was attributed to the high electrical conductivity and excellent electrocatalytic activity of GR and good biocompatibility of ACA. Moreover, Nafion/Mb–ACA–GR/CILE exhibited good electrocatalytic activity towards TCA with the linear range from 2.5 to 47.3 mmol L−1 and lower KMapp value of 8.3 mmol L−1. Moreover, the modified electrode also revealed good stability, reproducibility and accurate detection of tap-water, exhibiting great potential for the applications as the third-generation electrochemical biosensors.

研究领域: 生物医学工程 · 电化学传感 · 纳米生物技术 · 分子生物学 · 分析化学 · 生物传感器
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
POLYMER BULLETIN · 2016 ·Vol. 74 ·期 1 ·75-90 · IF 1.371

A novel biosensor based on electro-co-deposition of sodium alginate-Fe3O4-graphene composite on the carbon ionic liquid electrode for the direct electrochemistry and electrocatalysis of myoglobin

Chen Xiuqiong,Yan Huiqiong,Shi Zaifeng,Feng Yuhong,Li Jiacheng,Lin Qiang,Wang Xianghui,Sun Wei

A novel biosensor based on electro-co-deposition of myoglobin (Mb), sodium alginate (SA), Fe 3 O 4 -graphene (Fe 3 O 4 -GR) composite on the carbon ionic liquid electrode (CILE) was fabricated using Nafion as the film forming material to improve the stability of protein immobilized on the electrode surface, and the modified electrode was abbreviated as Nafion/Mb-SA-Fe 3 O 4 -GR/CILE. FT-IR and UV–vis absorption spectra suggested that Mb could retain its native structure after being immobilized in the SA-Fe 3 O 4 -GR composite film. The electrochemical behavior of the modified electrode was studied by cyclic voltammetry, and a pair of symmetric redox peaks appeared in the cyclic voltammograms, indicating that direct electron transfer of Mb was realized on the modified electrode, which was ascribed to the good electrocatalytic capability of Fe 3 O 4 -GR composite, the good biocompatibility of SA and the synergistic effects of SA and Fe 3 O 4 -GR composite. The electrochemical parameters of the electron transfer number ( n ), the charge transfer coefficient ( α ) and the electron transfer rate constant ( k s ) were calculated as 0.982, 0.357 and 0.234 s −1 , respectively. The modified electrode exhibited good electrocatalytic ability to the reduction of trichloroacetic acid (TCA) with wide linear range from 1.4 to 119.4 mmol/L, low detection limit as 0.174 mmol/L (3 σ ), good stability and reproducibility.

研究领域: 生物传感器 · 电化学 · 蛋白质电化学 · 纳米材料 · 生物相容性材料 · 分子诊断 · 转化医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY · 2026 ·Vol. 74 ·期 30 ·23914-23923 · IF 6.7

Hand-Held Electrostatic Spray Ionization Mass Spectrometry Enables On-Site Metabolomic Analysis of Sophora japonica and Robinia pseudoacacia

Song Mengyang,Luo Haiyan,Ji Zhenyang,Ye Zhihao,Yang Qinqin,Liu Xiaoyi,Shi Buyin,Li Yuze,Nie Zongxiu

Mass spectrometry plays a key role in agricultural and food chemistry, yet direct ionization of plant samples is complicated by endogenous salts and other matrix components that destabilize conventional direct-current nanoelectrospray ionization (DC-nanoESI). To address this limitation in point-of-need analysis, we developed hand-held electrostatic spray ionization (HESSI), which produces stable ionization from nanoliter sample volumes without direct electrical contact with the solution. A compact pulsed-discharge module and dielectric barrier limit electrochemical reactions and reduce the risk of discharge at the emitter while remaining compatible with salt-containing plant extracts. Approximately 50 nL of the sample sustained MS signals for up to 5 min. In a proof-of-concept application, 208 compounds were tentatively annotated from Sophora japonica and Robinia pseudoacacia extracts in negative-ion mode, and a neural network model distinguished the two groups with an accuracy of 83.3%. These results support HESSI as a compact and sample-efficient platform for the rapid mass-spectrometric characterization of botanical materials.

CAS / MDL: 80126-51-8 100684-32-0
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF APPLIED PHYCOLOGY · 2022 ·Vol. 34 ·期 3 ·1497-1511 · IF 3.404

In silico and in vitro assessment of bioactive peptides from Arthrospira platensis phycobiliproteins for DPP-IV inhibitory activity, ACE inhibitory activity, and antioxidant activity

Liu Jing,Bai Xinpeng,Fu Pengcheng

Arthrospira platensis proteins are considered as viable ingredients for functional foods with nutraceutical properties and health-promoting effects. In this study, we used five different proteases including pepsin, trypsin, alcalase, papain, and bromelain to hydrolyze A. platensis phycobiliprotein. LC–MS/MS (liquid chromatography-tandem mass spectrometry) was used to determine the composition of the hydrolysates with thousands of bioactive peptides. Based on peptide sequencing, a candidate list of 1,333 bioactive peptides was constructed for the first time for which bioinformatics tools were used to assess the properties of the bioactive peptides. The inhibitory activity of dipeptidyl peptidase IV (DPP-IV) and angiotensin-converting enzyme (ACE), as well as the antioxidant activity of five phycobiliprotein hydrolysates (PBPHs), were verified in vitro. The IC 50 values of PBPH-pepsin, PBPH-trypsin, PBPH-alcalase, PBPH-papain, and PBPH-bromelain for DPP-IV inhibited activity were determined to be 4.059, 5.603, 5.257, 3.819, and 4.195 mg mL −1 , respectively. All the above five PBPHs were also seen to significantly inhibit ACE activity ( P  < 0.0001) in the range of 0.1–1.0 mg mL −1 . The activity of five PBPHs fraction was found for the 2-azino-bis (3-ethylbenzothiazoline6-sulfonic acid) diammonium salt (ABTS) assay (the highest was 1.37 mM Trolox equivalent of 30 mg mL −1 of PBPH-trypsin), 1,1diphenyl-2-picrylhydrazyl (DPPH) assay (the highest was 204.67 µM Trolox equivalent of 10 mg mL −1 of PBPH-pepsin), and Fe 2+ chelating ability (the highest was 639.73 µM FeSO 4 equivalent of 10 mg mL −1 of PBPH-trypsin). This study indicated that it was feasible to utilize A. platensis phycobiliprotein as a source of bioactive peptides which may be used as functional food and/or nutritional supplements for human health.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2025 · IF 6.7

Hand-Held Nanoelectrospray Ionization with Frequency and Amplitude Tunability for Metabolomics of Saline Biosamples

Mengyang Song,Yuze Li,Wenbo Ma,Junyu Chen,Zongxiu Nie

Pulsed nanoelectrospray ionization (nanoESI) mass spectrometry has been proven to have several merits compared to its direct current (DC) counterparts, such as high sensitivity, high matrix tolerance, and low electrochemical interference. However, the reliance on external devices like signal generators and power amplifiers limits the technology’s suitability for on-site use. Here, we developed a frequency-amplitude tunable hand-held pulsed high-voltage supply specifically designed for nanoESI. This portable detection system eliminates reliance on bulky ancillary equipment of conventional approaches, with a total mass of 185 g and an ergonomic hand-held configuration. Through systematic modulation of frequency (10–50 kHz) and voltage (1.5–6 kV), the device achieves optimal detection performance across diverse analytical standards and complex matrixes, including serum and cellular samples. The pulse-induced self-cleaning effect prevented nozzle clogging while maintaining functionality under high-salt conditions (855 mM NaCl). To demonstrate clinical applicability, we analyzed 198 serum specimens (100 from atherosclerotic cardiovascular disease patients (ASCVD) and 98 age-matched controls), identifying statistically significant dysregulation of multiple metabolites in the ASCVD cohort and achieving a diagnostic accuracy of 85%. Field deployment trials using portable mass spectrometers further validated the system’s potential for rapid on-site diagnostics, establishing a new paradigm for point-of-care analytical technology.

CAS / MDL: 80126-51-8 100684-32-0
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。