文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
脂钙素-2
Analytical Methods · 2020 ·Vol. 12 ·期 15 ·1988-1994 · IF 2.596

A bimetallic PtPd hybrid nanostructure-amplified enzyme-free conductometric immunoassay for lipocalin-2 in renal cell carcinoma on an interdigitated micro-comb electrode

Chaoqun Huang,Fengling Zhang,Qingshui Wang,Yao Lin,Jiyi Huang

A new enzyme-free conductometric immunoassay based on bimetallic PtPd hybrid nanostructures was developed for the sensitive determination of lipocalin-2 in renal cell carcinoma. An immunosensor was prepared by immobilizing the capture antibody on an interdigitated micro-comb electrode, whereas bimetallic PtPd hybrid nanostructures were utilized for the conjugation of the detection antibody. Initially, a sandwich immunoreaction was carried out between the capture antibody and detection antibody in the presence of lipocalin-2 on the functional interdigitated micro-comb electrode. Thereafter, the immobilized PtPd bimetallic nanostructures could be used as enzymatic mimics to catalyze the reaction of hydrogen peroxide (H2O2) in 0.01 M phosphate buffer solution (pH 7.4) containing KI, thereby resulting in the local variation in the conductivity of the modified electrode. Several labeling strategies using Pt nanoparticles, Pd nanoparticles and bimetallic PtPd hybrid nanostructures were investigated for the detection of lipocalin-2, and improved analytical features were acquired with PtPd bimetallic nanostructures. With the PtPd labeling method, the factors influencing the analytical performance of the conductometric immunoassay were studied in detail. The strong attachment of biomolecules to the interdigitated micro-comb electrode and PtPd bimetallic nanostructures enabled a good repeatability and intermediate precision down to 10.4%. The dynamic concentration range spanned from 10 pg mL−1 to 30 ng mL−1 with a low detection limit of 5.9 pg mL−1 lipocalin-2 under optimum conditions. The reliability of the conductometric immunoassay was verified for the detection of lipocalin-2 in 4 blood serum and 4 urine samples and matched well with that obtained from the commercial lipocalin-2 enzyme-linked immunosorbant assay kit.

研究领域: 生物传感器 · 纳米技术 · 癌症诊断 · 电化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。