文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
自塑化
JOURNAL OF MATERIALS SCIENCE · 2024 ·Vol. 59 ·期 34 ·16129-16140 · IF 3.5

Self-plasticized Ca2+-selective electrode with polyaniline and copolymer of aniline and 2,5-dimethoxyaniline as solid contact layers

Wang Youwei,Wang Xiushan,Xu Huan,Wu Ang,Chen Ying,Li Guiqiang,Dong Chuanxin,Li Yahui,Mei Chao,Li Shuailin,Zhang Hehu

To address solubility, plasticizer leakage, and ionic carrier issues in PVC-based solid ion-selective electrodes, a novel plasticizer-free photocurable solid Ca 2+ -selective electrode (GC/PANI/CPANI/Ca 2+ (PBA)-ISE) was developed using a novel electrode structure. A new Ca 2+ -sensitive membrane based on poly(butyl acrylate) (PBA) was synthesized by ultraviolet polymerization, with conductive polyaniline (PANI) as the solid contact layer and a copolymer of aniline and 2,5-dimethoxyaniline (CPANI) as the coating. All potential electrochemical tests were carried out on the prepared Ca 2+ -selective electrode. The response slope of the electrode was 28.33 mV decade −1 , the detection limit was 6.9 × 10 −6  M, the stable linear range was 1 × 10 −6 to 1 × 10 −2  M, and it had a good Nernst response. The chronopotentiometric analysis and water layer tests showed that the potential drift of GC/PANI/CPANI/Ca 2+ (PBA)-ISE was as low as 0.0125 mV s −1 and 1.247 mV h −1 . In addition, the interference tests of environmental factors were carried out. When the electrode was in different interference light and gas environments, the potential changes of 1.6 × 10 −4  mV s −1 and 1.2 × 10 −3  mV s −1 were observed. Compared with previous reports and commercial electrodes, the prepared GC/PANI/CPANI/Ca 2+ (PBA)-ISE showed good electrochemical performance, and the recovery rate in Ca 2+ test solutions was higher (97.2–99.9%). This study provided theoretical insights to address solubility, plasticizer leakage, and ion carrier leakage issues in solid-state contact ion-selective electrodes. At the same time, this study provided a new structure and preparation method for the preparation of all-solid-state Ca 2+ -selective electrode. Graphical abstract

研究领域: 分析化学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。