By using magnetic graphitized carbon black and primary secondary amine (GCB/PSA/MNPs) as adsorbent, a modified quick, easy, cheap, effective, rugged and safe (QuEChERS) method was proposed for pesticide residue analysis in vegetables. The magnetic adsorbent was fabricated via simple co-mixing method based on an “aggregate warp” mechanism. To achieve the optimum conditions of modified QuEChERS toward target analytes, several parameters, including the composition of analyte protectants and the amount of the adsorbents were investigated. Under the optimized conditions, a simple, rapid and effective method for the determination of 10 pesticide residues in vegetables was established by coupling modified QuEChERS to gas chromatography/mass spectrometry analysis. The detection limits of the proposed method for 10 pesticides ranged from 0.39 to 8.6 ng/g. Good linearity ( R value ≥ 0.990) was achieved at concentration levels of 10–200 ng/g, and acceptable method reproducibility was found as intra- and inter-day precisions, yielding the relative standard deviations less than 10.7% and 13.4%, respectively. The recoveries were in the range of 69.9–125.0% at different concentrations for real samples. Compared with the reported methods for the determination of a large number of samples, the proposed method has the advantage of less time-consuming in clean-up procedure.
Xiaoyu Su,Zhiyu Chen,Huan Wang,Lei Yuan,Kaiyi Zheng,Wen Zhang,Xiaobo Zou
A ratiometric electrochemical immunosensor, based on DNA tetrahedron nanostructure (DTNS), is introduced for vegetable phoxim determination. DTNS spontaneously adheres onto gold-nanoparticle-modified electrode and forms stable three-dimensional structure, providing plenty of binding sites to the built-in reference, methylene blue (MB). Monoclonal antibody (m-Ab) is vertically linked onto DTNS vertex, selectively responses antigenic phoxim, and promotes the target signal of I PHO . Thus, a ratiometric indicator, I PHO / I MB , is sensibly established with the target signal ( I PHO ) and the reference signal ( I MB ). Modifications, mechanisms and advances of the proposed method are subsequently examined with morphological methods and electrochemical experiments. This method brings considerable advances in analytical behaviors. The ratiometric signal presents better performance than solo system in repeatability and long-time stability. As-fabricated sensor presents wide dynamic range as 0.1∼30 μg/L, and limit of detection is well defined as 0.003 μg/L (S/N = 3). Finally, this method is verified with real-vegetable-sample analysis, certified HPLC and recovery test.