文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

10 项

设置提升方向
透析液
Biomass Conversion and Biorefinery · 2021 ·Vol. 13 ·期 13 ·11499-11511 · IF 4.987

Adsorption of uremic toxins using biochar for dialysate regeneration

Wang Wei,Wang Zhijuan,Li Kai,Liu Yuxin,Xie Delong,Shan Shaoyun,He Liang,Mei Yi

Numerous studies have shown that patients with COVID-19 have a high incidence of renal dysfunction. However, the dialysis supplies, including dialysates, are also severely inadequate in hospitals at the pandemic centers. Therefore, there is an urgent need to develop materials that can efficiently and rapidly remove toxins and thus regenerate dialysate to make this vital resource remains readily available. In this work, by simple carbonization and activation treatment, the porous activated carbon from waste rubber seed shell (RAC) was prepared. The adsorption results showed that the maximum adsorption capacities of the obtained RAC for creatinine and uric acid were 430 mg/g and 504 mg/g, respectively. Significantly, the adsorption process can be close to the equilibrium state within 0.5 h, which proved the ultra-fast adsorption response capacity of RAC. Further, the thermodynamics analysis results showed that both the creatinine and uric acid adsorption processes were monolayer, exothermic, and spontaneous. The adsorption kinetics results indicated that the adsorption process of the two uremic toxins followed the pseudo-second-order rate model and was dominated by chemisorption. The instrument analysis results reflected the efficient adsorption of the RAC for the above uremic toxins which might be due to the dipole–dipole interaction between the dipolar oxygen-containing groups of the surface of RAC and the dipoles of the toxins. Moreover, the formed hydrogen bonds between the oxygen groups and the toxins also played an important role. In all, the as-prepared RAC has the potential to efficiently remove major toxins from the dialysate and can be used in in vitro dialysis of numerous patients during the current COVID-19 pandemic.

研究领域: 医学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2020 · IF 6.785

I-motif Formed at Physiological pH Triggered by Spatial Confinement of Nanochannels: An Electrochemical Platform for pH Monitoring in Brain Microdialysates

Lu Shi,Feifei Cao,Limin Zhang,Yang Tian

The development of switches responding to specific pH changes was particularly useful in wide application fields. Owing to flexible switches simulated by pH, i-motif DNAs are widely used as a pH sensor. But its character of structure transition strongly dependent on acidic pH severely hampers the application of i-motif DNA in physiological media. Herein, we report the stable i-motif structure formed at a physiological pH triggered by spatial confinement of silica nanochannels. Three classic DNA chains containing 21-mer i-motif domain base-pairs and a single-stranded multiply (T)n spacer, 5′-COOH-(T)n-CCCTAACCCTAACCCTAACCC-3′, were employed to evaluate the enhanced stability of i-motif structure. Compared to their free states in a dilute solution, the transition pH of all i-motif DNAs decorated in nanochannels remarkably shifts toward a neutral pH. Moreover, the transition midpoint can be tuned sensitively over the physiologically relevant pH range through slightly varying the length of T base spacer. Density functional theory (DFT) calculations validate that the increased proton density in a nanochannel triggers the formation of an i-motif structure under a neutral pH. Finally, this i-motif DNA based nanochannels electrode was successfully employed to monitor pH in brain microdialysates followed by cerebral ischemia. The present approach is not limited by fundamental investigation for DNA conformation but may extend toward the manipulation of i-motif based structures for artificial molecular machines and signaling systems.

研究领域: 生物化学 · 分子生物学 · 医学检测
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Canadian Journal of Infectious Diseases & Medical Microbiology · 2025 ·Vol. 2025 ·期 1 ·5553355 · IF 2.6

Stability of Daptomycin in Dextrose and Icodextrin-Based Peritoneal Dialysis Solutions

Kai Ming Chow,Siu Kwan Wo,Simon Wai Yin So,Phyllis Mei Shan Cheng,Keary Rui Zhou,Wai Li Lim,Joan Zhong Zuo,Philip Kam Tao Li

Background: With emerging antibiotic resistance, many patients on peritoneal dialysis require newer antibiotic treatment such as daptomycin. Inadequate clinical information exists across different peritoneal dialysis solutions, including icodextrin, for the stability of intraperitoneal daptomycin. To guide the clinical practice of intraperitoneal daptomycin treatment, we need to establish the stability of daptomycin at dextrose concentration higher than 1.5% and icodextrin, as well as the duration of stability. Methods: We tested the stability of daptomycin in three types of peritoneal dialysis bags (UltraBag dextrose 2.5%, UltraBag icodextrin 7.5%, and Stay-Safe Balance 2.3%). Daptomycin was reconstituted with water for injection (50 mg/mL), followed by administration to peritoneal dialysis bags to obtain the final daptomycin concentrations of 70 μg/mL (equivalent to 140 mg/2L, the maintenance level) and 245 μg/mL (equivalent to 490 mg/2L, the loading level). The bags were then placed at ambient temperature (25°C) followed by withdrawing 5 mL samples at 0, 4, 8, 12, 24, and 48 h for UltraBag dextrose 2.5% and UltraBag icodextrin 7.5% and 0, 4, 8, 12, and 24 h for Stay-Safe Balance 2.3%. The concentrations of daptomycin in the collected samples were quantified by high-performance liquid chromatography with diode array detector (HPLC-DAD). Results: Under ambient condition, daptomycin was stable at maintenance level in UltraBag dextrose 2.5% for 48 h and in UltraBag icodextrin 7.5% or Stay-Safe Balance 2.3% for 24 h. For loading level, daptomycin was stable in UltraBag dextrose 2.5% and Stay-Safe Balance 2.3% for 12 h and in UltraBag icodextrin 7.5% for 48 h. Conclusions: Current stability results support and guide the use of intraperitoneal daptomycin in different dialysis solutions. Patients with peritonitis requiring icodextrin exchange and assisted preparation of daptomycin can benefit from nurses who provide daily home visit based on our stability results.

CAS / MDL: 103060-53-3
研究领域: 药理学 · 临床医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2015 · IF 5.636

A Selective and Accurate Ratiometric Electrochemical Biosensor for Monitoring of Cu2+ Ions in a Rat Brain

Limin Zhang,Yingying Han,Fan Zhao,Guoyue Shi,Yang Tian

Metals are essential components of all living cells, and in many cases cells trigger and utilize dynamic metal movements for signaling purposes. So, it is very critical to develop the biosensors for determination of metal ions in living systems with high selectivity and accuracy. In this work, taking Cu2+ as a model, an accurate and selective ratiometric electrochemical biosensor was developed. First, the specific molecule, 2,2′,2″-(2,2′,2″-nitrilotris(ethane-2,1-diyl)-tris((pyridin-2-ylmethyl)azanediyl)triethanethiol (TPAASH), was designed and synthesized for specific recognition of Cu2+. Meanwhile, electroactive molecule, 6-(ferrocenyl)hexanethiol (FcHT) was coimmobilized with TPAASH at one electrode as inner reference molecule to provide a built-in correction for avoiding the environmental effects. Thus, the developed biosensor demonstrated high accuracy and remarkable selectivity toward Cu2+ against other metal ions, amino acids, and so on. In addition, the biosensor also showed high sensitivity due to the electrocatalytic activity of the nanostructured gold flowers. As a result, the present ratiometric electrochemical biosensor was successfully applied in detection of Cu2+ in brain microdialysates of normal rat brain and that followed by global cerebral ischemia.

研究领域: 生物传感技术 · 神经科学 · 分析化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
CHEMICAL ENGINEERING JOURNAL · 2022 · IF 16.744

Toward Urease-free wearable artificial kidney: Widened interlayer spacing MoS2 nanosheets with highly effective adsorption for uremic toxins

Haixin Zhao,Jia Huang,Lu Miao,Yuqi Yang,Zuoxiu Xiao,Qiaohui Chen,Qiong Huang,Kelong Ai

The high incidence of kidney disease caused by various factors (such as COVID-19) has triggered an extreme desire for wearable artificial kidney (WAK). Nevertheless, the dialysate regeneration system in WAK presents a very low adsorption capacity of urea, and must rely on the help of urease and zirconium compounds, which make the device too complex and costly, thus limiting their application. In this study, we employ the adsorption activity of defect-rich MoS 2 nanosheets with widened interlayer spacing (WDR-MoS 2 ) for the elimination of three crucial uremic toxins (urea, creatinine, and uric acid). The high adsorption performances of WDR-MoS 2 are owing to the presence of abundant S atoms between the two MoS 2 sheets that can efficiently adsorb uremic toxins through the unique S–N bond. Furthermore, widening the layer spacing of MoS 2 is similar to adjusting the aperture of a filter, which can not only speed up the transport of uremic toxins but also prevent the passage of large molecules (such as proteins). Thus, the WDR-MoS 2 can neither affect cell viability nor produce hemolysis and coagulation in the blood. Finally, a home-made WDR-MoS 2 fixed-bed system without urease and zirconium compounds is used to efficiently remove uremic toxins in the dialysate. WDR-MoS 2 is expected to fundamentally solve the materials science challenges in WAK and provide a new design idea for the development of high-performance 2D material-based adsorbents.

研究领域: 材料科学 · 纳米技术 · 生物医学工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
TALANTA · 2016 · IF 4.035

Determination of dopamine, serotonin, biosynthesis precursors and metabolites in rat brain microdialysates by ultrasonic-assisted in situ derivatization–dispersive liquid–liquid microextraction coupled with UHPLC-MS/MS

Na Wei,Xian-En Zhao,Shuyun Zhu,Yongrui He,Longfang Zheng,Guang Chen,Jinmao You,Shu Liu,Zhiqiang Liu

This paper, for the first time, reported a simple, rapid, sensitive and environmental friendly ultrasonic-assisted in situ derivatization-dispersive liquid–liquid microextraction ( in situ UAD-DLLME) method followed by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for the simultaneous determination of dopamine (DA), serotonin (5-HT) and their biosynthesis precursors and metabolites in rat brain microdialysates. In this work, a commercial reagent, Lissamine rhodamine B sulfonylchloride (LRSC), was proposed as a derivatization reagent. The ionization efficiency of neurotransmitters was greatly enhanced through the introduction of a permanent charged moiety of LRSC into their derivatives during electrospray ionization MS (ESI–MS) analysis. Parameters of in situ UAD-DLLME and UHPLC-MS/MS conditions were all optimized in detail. The optimum conditions of in situ UAD-DLLME were found to be as follows: a mixture of 150   μL of acetonitrile (dispersant) containing LRSC (derivatization reagents) and 50   μL of low toxic bromobenzene (extractant) was rapidly injected into an aqueous sample containing 30   μL of microdialysate and 800   μL of NaHCO 3 -Na 2 CO 3 buffer solution (pH 10.5) at 37   °C. After ultrasonication for 3   min and centrifuging for 2   min, the sedimented phase was conveniently injected for UHPLC–MS/MS analysis. Under the optimized conditions, good linearity was observed with the limits of detection (LODs, S/N>3) and limits of quantification (LOQs, S/N>10) in the range of 0.002–0.008 and 0.015–0.040   nmol/L, respectively. Meanwhile, it also brought good results of precision (3.2–13.0%, peak area RSDs %), accuracy (86.4–112%), recovery (73.9–105%), matrix effect (86.2–105%), and stability (3.1–8.8%, peak area RSDs %). The developed method was successfully applied for the simultaneous determination of multiple neurotransmitters, their precursors and metabolites in brain microdialysates of normal and L -DOPA induced dyskinesias (LID) rats.

研究领域: 神经科学 · 分析化学 · 药理学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
Nanomaterials · 2022 ·Vol. 12 ·期 3 ·418 · IF 5.719

Controllable Fabrication of Molecularly Imprinted Microspheres with Nanoporous and Multilayered Structure for Dialysate Regeneration

Hongchi Wu,Shanguo Zhang,Lu Liu,Yukun Ren,Chun Xue,Wenlong Wu,Xiaoming Chen,Hongyuan Jiang

Adsorption of urea from dialysate is essential for wearable artificial kidneys (WRK). Molecularly imprinted microspheres with nanoporous and multilayered structures are prepared based on liquid–liquid phase separation (LLPS), which can selectively adsorb urea. In addition, we combine the microspheres with a designed polydimethylsiloxane (PDMS) chip to propose an efficient urea adsorption platform. In this work, we propose a formulation of LLPS including Tripropylene glycol diacrylate (TPGDA), ethanol, and acrylic acid (30%v/v), to prepare urea molecularly imprinted microspheres in a simple and highly controllable method. These microspheres have urea molecular imprinting sites on the surface and inside, allowing selective adsorption of urea and preservation of other essential constituents. Previous static studies on urea adsorption have not considered the combination between urea adsorbent and WRK. Therefore, we design the platform embedded with urea molecular imprinted microspheres, which can disturb the fluid motion and improve the efficiency of urea adsorption. These advantages enable the urea absorption platform to be highly promising for dialysate regeneration in WRK.Keywords:liquid–liquid phase separation;nanoporous microspheres;microfluidic technology;urea absorption

研究领域: 材料科学 · 生物医学工程 · 化学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2014 · IF 5.825

Ratiometric Fluorescent Probe Based on Gold Nanoclusters and Alizarin Red-Boronic Acid for Monitoring Glucose in Brain Microdialysate

Lu-Liang Wang,Juan Qiao,Hui-Hui Liu,Jie Hao,Li Qi,Xiao-Ping Zhou,Dan Li,Zong-Xiu Nie,Lan-Qun Mao

Glucose monitoring with high sensitivity and accuracy in the cerebrospinal fluid is a challenge for evaluating the role of glucose in the physiological and pathological processes. In this work, a ratiometric fluorescent probe for sensing glucose was developed. In the probe, the gold nanoclusters protected by ovalbumin played the role as the reference of fluorophore and the Alizarin Red S-3-aminophenyl boronic acid immobilized on the poly(N-acryloxysuccinimide) acted as both the response signal and specific recognition unit for sensing glucose. Once the ratiometric fluorescent probe reacted with glucose in the biological system, its fluorescence intensity at 567 nm was quenched, while the fluorescence intensity at 610 nm was essentially unchanged. In addition, the prepared ratiometric fluorescent probe showed higher stability against environmental effects. As a result, the present ratiometric fluorescent probe was successfully used for monitoring of glucose in the rat brain following the cerebral calm/ischemia.

CAS / MDL: 9003-99-0 7440-38-2
研究领域: 分析化学 · 生物医学工程 · 神经科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES · 2019 · IF 4.784

Urease immobilized GO core@shell heparin-mimicking polymer beads with safe and effective urea removal for blood purification

Jue Zhang,Zhenqiang Shi,Chao He,Xin Song,Ye Yang,Shudong Sun,Weifeng Zhao,Changsheng Zhao

Adsorbents are usually used to remove uremic toxins for blood purification. However, the removal of urea is still an intractable problem, since no effective material has been found for urea removal by physical adsorption. Here, urease immobilized graphene oxide core@shell heparin-mimicking polymer (U-GO-HMP) beads were designed, which exhibited good urea removal ability with a removal amount of about 635 mg/g and a removal ratio of about 80% from urea solution. In addition, urea could be removed from collected dialysate and the removal ratio could reach 60% within 480 min. Beyond that, the U-GO-HMP beads also showed good reusability with sustainable relative activity after 5 cycles. Furthermore, the U-GO-HMP beads exhibited good blood compatibility with low hemolysis ratio, suppressed complement activation and contact activation, as well as increased clotting times. It is worthy believing that the U-GO-HMP beads may have great potential in the field of blood purification for urea removal.

研究领域: 生物医学工程 · 材料科学 · 血液透析 · 血液净化
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2024 · IF 8

Development of a dual-mode Ru-UiO-TPEA MOF probe for highly sensitive and accurate detection of Cu2+ in biological systems

Qian Long,Hanfeng Cui,Jing Zhang,Qiqi Fan,Ting Huang,Hai Shuai,Xiaocui Yin,Guobing Wei,Huanwen Chen,Hao Fan

Cu 2+ serves as a significant biomarker in various physiological processes. This study presents the development of a novel Ru-UiO-TPEA functionalized metal-organic framework (MOFs) probe for Cu 2+ detection, employing both electrochemiluminescence (ECL) and electrochemical (EC) methods. Employing a dual ligand-assisted energy transfer approach, we synthesized Ru-UiO with optimal ECL and EC properties by adjusting the synthesis ratio of biphenyldicarboxylic acid to Ru(dcbpy) 3 2+ . This was followed by its conjugation with N-(2-aminoethyl)-N, N′, N′-tris(pyridin-2-ylmethyl) ethane-1,2-diamine (AE-TPEA) to form the highly conjugated Ru-UiO-TPEA probe for Cu 2+ detection. As the Cu 2+ concentration increased, the probe exhibited a diminished ECL signal and an enhanced differential pulse voltammetry (DPV) signal. The dual-mode detection method enabled cross-validation of the ECL and EC signals, enhancing accuracy and effectively minimizing errors. The ECL and EC methods had detection limits of 0.26 nM (range: 1 nM to 10 μM) and 0.65 nM (range: 2 nM to 80 μM), respectively. Meanwhile, these two methods can effectively detect Cu 2+ in rat brain microdialysis fluid. Notably, the measured concentrations correlated well with those determined by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), highlighting its potential in biological and clinical bioelectronic sensing applications.

研究领域: 分析化学 · 生物化学 · 生物医学工程 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。