文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
铂(II)卟啉
Advanced Healthcare Materials · 2022 ·Vol. 11 ·期 15 ·2200467 · IF 11.092

NIR-II J-Aggregated Pt(II)-Porphyrin-Based Phosphorescent Probe for Tumor-Hypoxia Imaging

Wansu Zhang,Shangyu Chen,Pengfei Sun,Shuai Ye,Quli Fan,Jun Song,Pengju Zeng,Junle Qu,Wai-Yeung Wong

The luminescence of traditional phosphorescence-based hypoxia probes is limited to the visible and first near-infrared wavelength regions (<1000 nm), which has defects of higher light scattering and lower penetration depth in contrast with the second near-infrared wavelength window (NIR-II, 1000–1700 nm) for optical bioimaging. Herein, 5,15-bis(2,6-bis(dodecyloxy)phenyl)-porphyrin platinum(II) (PpyPt) with J-aggregation induced NIR-II phosphorescence is reported. J-aggregates of PpyPt are confirmed by the X-ray diffraction data in the crystalline state. Moreover, the emission and excitation spectra of PpyPt in the solid states reveal NIR-II luminescence feature of PpyPt in J-aggregates. More importantly, by preparation of water-soluble PpyPt nanoparticles (PpyPt NPs 4.76 ) with J-aggregates, it has NIR-II phosphorescent lifetime of microseconds and good oxygen-sensitivity in water. Moreover, the good biological hypoxia-sensing potential of PpyPt NPs 4.76 is demonstrated in cells and 4T1-tumor-bearing mice. This study provides an efficient strategy to design NIR-II phosphorescent probe for sensitive tumor-hypoxia detection through the construction of J-aggregates.

CAS / MDL: 100-47-0 75-50-3
研究领域: 生物医学工程 · 光学成像 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2017 ·Vol. 41 ·期 14 ·6646-6652 · IF 3.269

High-performance dissolved oxygen sensors based on platinum(II) porphyrin embedded in polystyrene beads

Ke Zhang,Lingling Luo,Wenjie Li,Honglin Zhang,Yi Zhang,Jiupeng Zhao,Yao Li

The preparation of polystyrene (PS) beads loaded with platinum octaethylporphyrin (PtOEP) via a swelling method has been well incorporated into dissolved oxygen (DO) sensing detection. The experimental results showed that the highest value of I0/I100 was 7.26 and the loading ratio of PtOEP was 51.33%; the luminescent intensity declined by only 2.23% under UV light for 1 hour. The response and recovery times were 16 s and 180 s, respectively. The peak position and intensity of the emission spectrum in buffer solutions with different pH values did not change. This indicates that this oxygen sensor has excellent sensitivity, light stability, reversibility, and pH resistance. Moreover, on this basis, we incorporated another oxygen insensitive dye, coumarin 6 (C6), to prepare a ratiometric oxygen sensor, which showed high sensitivity towards O2 with superior quenching efficiency. Finally, this oxygen sensor was used to monitor the content of DO in fish tank, tap water, and the Songhua River. All the measured results were well within the reference range.

研究领域: 生物化学 · 材料科学 · 环境监测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2014 ·Vol. 182 ·期 3 ·687-693 · IF 3.719

Determination of quercetin using a photo-electrochemical sensor modified with titanium dioxide and a platinum(II)-porphyrin complex

Tian Li,Wang Binbin,Chen Ruizhan,Gao Ye,Chen Yanling,Li Tianjiao

A glassy carbon electrode (GCE) was modified with a film containing titanium dioxide and a Pt(II)-porphyrin complex, and its response to quercetin was investigated employing cyclic voltammetry and chronoamperometry. The oxidation current caused by quercetin is largely enhanced under UV illumination. The effects of pH value, mass of TiO 2 in the film, UV illumination time and applied potential were studied. Under optimized conditions, the peak current at a typically applied voltage of +0.4 V depends linearly on the concentration of quercetin in the 0.002 to 50 mg L −1 range. The detection limit (at an SNR of 3) is 0.8 μg L −1 . The method was successfully applied to the determination of quercetin in (spiked) samples of tea and apple juice. Figure Cyclic voltammograms of the TiO 2 /PtP/GCE in the absence and presence of various concentrations of quercetin in 0.1 M NaOH. a-e: 0, 0.1, 0.2, 0.3 and 0.4 mg L -1 .

研究领域: 分析化学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。