文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
铂薄膜
ELECTROANALYSIS · 2017 ·Vol. 29 ·期 8 ·1918-1924 · IF 2.851

Highly Sensitive Molecularly Imprinted Sensor Based on Platinum Thin-film Microelectrode for Detection of Chloramphenicol in Food Samples

Xiaojuan Zhao,Qimei Zhang,Haiguang Chen,Gongliang Liu,Weidong Bai

A highly sensitive and selective electrochemical biomimetic sensor was fabricated for fast detection of chloramphenicol (CAP) in honey and milk samples. Platinum thin-film microelectrode (Pt TFME), which could provide unique electrochemical properties and achieve measurement using very limited solution volumes, was surface-modified by electropolymerizing o -phenylenediamine. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the preparation process of CAP-imprinted poly( o -phenylenediamine) film and rebinding ability of CAP into the imprinted cavities. The electrochemical properties of the sensor were further investigated with square wave voltammetry (SWV) by using K 3 Fe(CN) 6 as an electroactive probe. The current difference of oxidation peaks of K 3 Fe(CN) 6 had a good linear relationship with the concentration of CAP in the range of 0.9–10 nM. The detection limit was 0.39 nM based on the signal to noise ratio of 3. The developed sensor was successfully applied to determine CAP in honey and milk samples, and the result was in good agreement with that obtained by high performance liquid chromatography-mass spectrometry (HPLC-MS). The sensor showed high sensitivity and excellent selectivity to CAP in comparison to other structurally related and/or normally existing antibiotics, and demonstrated great promise for the rapid quantification of CAP in real food samples and field analysis.

CAS / MDL: 95-54-5
研究领域: 分析化学 · 食品科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
IEEE SENSORS JOURNAL · 2024 · IF 4.3

Stability Enhancement of the Platinum Thin Film Temperature Detector up to 1400°C by Printing Al2O3 Protective Layer

Haigang Wang,Zhichun Liu,Biling Wang,Mingyang Kong,Dezhi Xu,Liangjie Gao,Qiang Li,Zhipeng Zhao,Wenqi Lu,Xin Zhao,Junsheng Liang

Platinum (Pt) resistance temperature detectors (RTDs) are extensively employed as thin-film temperature sensors. However, agglomeration of Pt thin films occurs above 800 °C due to grain boundary grooving on the free surface, ultimately limiting its application at high temperatures. In this work, a Pt RTD was prepared by depositing multilayer Al2O3 protective layer on Pt thin films using electrodynamic jet printing (EJP) technology. The surface morphology and energy-dispersive spectroscopy spectrum of Pt thin films indicated that the voids on the surface are reduced, the grains’ growth is inhibited, and the movement and grooving of grain boundaries are limited. The test results indicate that the Pt RTD has not failed after six cycles of repeated warming and cooling from 800 °C to 1300 °C. After repeated cycles, the initial resistance of the Pt RTD is with a rate of change of less than 0.5%. In addition, the maximum relative deviation of the resistance in a single cycle is less than 1.6%. The Pt RTD with an 18-layer Al2O3 protective layer has undergone 12 cycles without failure, indicating a cycle life exceeding 10 h. Pt RTDs are stable over the range of 25 °C–1400 °C with correlation coefficients R2 greater than 0.999, showing good linear correlation. It can withstand temperatures up to 1440 °C when printed with 18 protective layers. Compared to a Pt RTD without protective layers, the operating temperature is increased by 40%. This advancement provides a viable solution for the high-temperature monitoring of hot-end components in aerospace applications.

CAS / MDL: 555-31-7
研究领域: 材料科学 · 航空航天工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2024 · IF 8.3

Tunable Microwave Absorbing Devices Enabled by Reversible Metal Electrodeposition

Zhen Meng,Dongqing Liu,Shiqi Xing,Yongqiang Pang,Yan Jia,Mingyang Li,Mei Zu,Zi Wang,Tianwen Liu,Haifeng Cheng

Tunable microwave absorbers have gained significant interest due to their capability to actively control microwaves. However, the existing architecture-change-based approach lacks flexibility, and the active-element-based approach is constrained by a narrowband operation or small dynamic modulation range. Here, a novel electrically tunable microwave absorbing device (TMAD) is demonstrated that can achieve dynamic tuning of the average reflection amplitude between −13.0 and −1.2 dB over a broadband range of 8–18 GHz enabled by reversible metal electrodeposition. This reversible tunability is achieved by electrodepositing silver (Ag) layers with controlled morphology on nanoscopic platinum (Pt) films in a device structure similar to a tunable Salisbury screen, employing Ag electrodeposited on Pt films as the modifiable resistive layer. Furthermore, this TMAD possesses a simple device architecture, excellent bistability, and multispectral compatibility. Our approach offers a new strategy for dynamically manipulating microwaves, which has potential utility in intelligent camouflage and communication systems.

研究领域: 材料科学 · 电磁学 · 通信工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。