文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

5 项

设置提升方向
铅(II)检测
International Journal of Electrochemical Science · 2023 · IF 1.5

Barium Bismuthate Nanoribbons with Good Electrochemical Detection Performance for Pb(II)

Mao-Ting Ding,Xian-Zhang Ling,F.F. Lin,L. Pei,C.G. Fan

A facile hydrothermal process was used for the synthesis of barium bismuthate nanoribbons. The nanoribbons were applied as the sensing materials for sensitive detection of Pb(II). The micromorphology and structure of the prepared products were analyzed by scanning electron microscopy (SEM) and X-ray diffraction (XRD), respectively. The suspension with barium bismuthate nanoribbons was cast on the surface of a glassy carbon electrode (GCE). The barium bismuthate nanoribbons modified GCE was used for the detection of Pb(II) using square wave anodic stripping voltammetry (SWASV) technique. The results show that the fabricated GCE exhibited a linear range of 0.001-2 mM with the limit of detection (LOD) of 0.13 μM. The barium bismuthate nanoribbons modified GCE has a promising potential in practical application for the detection of real samples with water and soil.

研究领域: 材料科学 · 环境科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2012 ·Vol. 179 ·期 1 ·171-177 · IF 3.033

A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry

Yi Wen Jiao,Li Yang,Ran Gu,Luo Hong Qun,Li Nian Bing

We have developed a sensor for the square wave anodic stripping voltammetric determination of Pb(II). A glassy carbon electrode was modified with a thin film of an antimony/poly(p-aminobenzene sulfonic acid) composite in air-saturated aqueous solution of pH 2.0. Compared to a conventional antimony film electrode, the new one yields a larger stripping signal for Pb(II). The conditions of polymerization, the concentration of Sb(III), the pH value of the sample solution, the deposition potential and time, frequency, potential amplitude, and step increment potential were optimized. Under the optimum conditions, a linear response was observed for Pb(II) in the range of 0.5 to 150.0 μg L −1 . The detection limit for Pb(II) is 0.1 μg L −1 . The surface of a glassy carbon electrode (GCE) was modified by electropolymerization of p-aminobenzene sulfonic acid (p-ABSA) and the modified electrode was then prepared by in situ depositing antimony and target metal on the poly(p-ABSA) coated glassy carbon electrode. The antimony/poly(p-ABSA) film electrode displays high electrochemical activity in giving a peak current that is proportional to the concentration of Pb(II) in a certain range.

研究领域: 生物医学工程 · 环境监测 · 分析化学 · 电化学传感 · 重金属检测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2021 · IF 4.821

Indium-doped mesoporous Bi2S3-based electrochemical interface for highly sensitive detection of Pb(II)

Shiqi Wang,Jinrui Li,Yanqiu Fu,Zhongxin Zhuang,Zhonggang Liu

As a global toxic pollutant, lead (Pb(II)) causes serious risks for living organism and the environment, it is thus of critical importance to explore a facile and efficient sensing protocol for the detection of Pb(II). Herein, we proposed the flower-like In-doped Bi 2 S 3 (IDB) with mesoporous nanostructure as an electrochemical sensing interface for the Pb(II) detection, which was synthesized via a facile solvothermal method. The fabricated IDB/GCE exhibited a high sensitivity of 78.1 μA·μM −1 and a satisfied detection limit (LOD) as 0.017 μΜ with robust stability and remarkable anti-interference capability. Plausible mechanism of electrochemical sensing of Pb(II) was proposed based on electrochemical and characterization results, where the mesoporous IDB could provide numerous electrocatalytic active sites, and efficiently accumulate target Pb(II) onto the electrode surface, leading to the improved electrochemical performance. Besides, the complex state of Pb(II) was analyzed with IDB/GCE, and a tentative reference on the detection of complex state of Pb(II) was achieved with the favorable results. Furthermore, the fabricated IDB/GCE could be applied for the analysis of Pb(II) in real water sample with high reliability.

CAS / MDL: 10035-06-0
研究领域: 环境科学 · 分析化学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2019 ·Vol. 186 ·期 12 ·1-8 · IF 5.479

Photoelectrochemical aptasensor for lead(II) by exploiting the CdS nanoparticle-assisted photoactivity of TiO2 nanoparticles and by using the quercetin-copper(II) complex as the DNA intercalator

Niu Yanyan,Luo Guiling,Xie Hui,Zhuang Yujiao,Wu Xianqun,Li Guangjiu,Sun Wei

A photoelectrochemical (PEC) aptasensor for Pb(II) detection is described. A nanocomposite consisting of CdS (2.5 μm) and TiO 2 nanoparticles (10 nm) was used as a photoactive material, and gold nanochains (Au NCs) as the support for immobilization of the Pb(II)-binding aptamer. The quercetin-copper(II) complex was further employed as the intercalator for the improvement of the photoactivity by embedding it into dsDNA. In the presence of Pb(II), a Pb(II)-stabilized G-quadruplex was formed between Pb(II) and DNA S1. This is accompanied by unwinding of the dsDNA and the release of the quercetin-copper(II) complex from the surface of the sensor. This results in a decrease of the photocurrent that drops linearly from 5.0 × 10 −12 to 1.0 × 10 −8  mol·L −1 Pb(II) concentration range with a detection limit of 1.6 × 10 −12  mol·L −1 . The method was applied to the determination of Pb(II) in various samples and gave satisfactory results. A photoelectrochemical aptasensor was fabricated for the detection of Pb(II) based on CdS-TiO 2 nanocomposite modified indium tin oxide (ITO) electrode. Gold nanochains (AuNCs) were used as anchor to immobilize the aptamers S1 and S2 that form a double helix structure by DNA hybridization. After embedding of quercetin-copper(II) complex as intercalator and electron donor, the concentrations of Pb(II) were determined by the changes of photocurrents.

研究领域: 分析化学 · 纳米技术 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2013 · IF 5.437

Colorimetric sensor strips for lead (II) assay utilizing nanogold probes immobilized polyamide-6/nitrocellulose nano-fibers/nets

Yan Li,Yang Si,Xueqin Wang,Bin Ding,Gang Sun,Gang Zheng,Wenjing Luo,Jianyong Yu

A facile, ultrasensitive, reproductive and selective sensor strip utilizing electrospun polyamide-6/nitrocellulose (PA-6/NC) nano-fibers/nets (NFN) membranes assemble bovine serum albumin decorated Au nanoparticles (BAu probe) for naked-eye colorimetric assay of Pb 2+ has successfully prepared through dual-component alternate distribution multifluidic electrospinning technique . Benefiting from the extremely large specific surface areas and high porosity of NFN membranes, the stability of BAu probe dramatically increased and the strips presented a significant absorbance decreasing band at 546   nm which induce the visual color changes from deep pink to white after incubated in Pb 2+ liquor with a low detection limit of 0.2   μM without any assistance of equipment. Upon exposure to a series of metal ions , only Pb 2+ could induce a pink-to-white color change, which clearly exhibited that BAu probe immobilized PA-6/NC membranes could act as highly selective strips to detect Pb 2+ with little interference from other metal ions. Additionally, the colorimetric responses are represented in visualized quantitative by calculated color difference from L ⁎ a ⁎ b ⁎ coordinates which are presented with lightness and chrome values. Furthermore, the sensitivity of NFN membrane-based strips is much higher than that of film-based ones. The results indicate that this promising cost-effective sensing system could potentially allow for assaying of Pb 2+ in human urine or blood as preliminary screening of lead poisoning.

研究领域: 分析化学 · 环境科学 · 材料科学 · 纳米技术
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。