Determination of antipsychotics from biological samples is meaningful in the field of clinical and forensic medicine. Compared to blood, keratinized matrices such as hair and nails have attracted increasing attention in drug analysis for wider detection window. Nevertheless, the distribution and stability of antipsychotics in keratinized matrices are not clarified yet. Therefore, we developed a LC-MS/MS based method for simultaneous determination of 10 antipsychotics from blood, hair and nails, with high recovery (78.1–107.4%, 71.3–93.5% and 75.2–90.5%), low LOD (5–10 pg/mL, 5–10 pg/mg and 5 pg/mg) and high accuracy (96.0%−101.6%, 97.5%−102.5% and 97.6–101.7%). The method was applied to sets of blood, hair, and nail samples of 54 patients who received long-term therapy, and significant correlations between drug concentrations in blood and hair was found, while the correlation between nails and other matrices varied depending on the drug. Except for olanzapine , the concentrations of antipsychotics in segmental hair samples were consistent with drug exposure. Besides, the hair and nail samples of suspects in two forensic cases were analyzed and provided supporting evidence for the suspects’ psychiatric state. Our research offered a deeper understanding of keratinized matrix as stable and retrospective bio-samples for antipsychotics detection in forensic practice.
Junlei He,Jiahao Yuan,Juan Du,Xiaoguang Chen,Xinguo Zhang,Ande Ma,Jialiang Pan
An automated on-line solid-phase extraction (SPE) method coupled with high performance liquid chromatography (HPLC) was developed for the first application to rapid quantification of trace amisulpride in human plasma. A kind of restricted-access media (RAM) column (Capcell Pak MF Ph-1) was adopted for highly efficient extraction of amisulpride and meanwhile for the limited access of macromolecular matrices. It was robust and reusable for >1000 times. The utilization of two programmable pumps enabled the simultaneous execution of SPE and HPLC analysis within 10 min. Additionally, using appropriate valve-switching time was found to efficiently reduce the contamination of HPLC system caused by co-elution of impurity from an RAM column, facilitating continuous analysis of large-scale samples. The method was characterized by free of internal standard (IS), which exhibited low limit of detection (0.0035 μg·mL −1 ), satisfactory precision and accuracy (recoveries of 98.1%–104.6% with relative standard deviations below 4.6%). Amisulpride was successfully detected in the plasma samples originated from four patients. Notably, interindividual differences of plasma sample matrices did not yield an adverse effect on the accuracy of our IS-free method. The comparison to previous methods shows the superiority of the method in terms of sensitivity, IS requirement, speed, and automation. Thus, the method has great potential for the application to therapeutic drug monitoring as well as large-scale bioanalytical and clinical studies.
The purpose of this work was to investigate the crystal structures and physicochemical properties of amisulpride polymorphs. Except of the previously reported polymorph (named as Form I), a new polymorphic form (named as Form II) was discovered through comprehensive solid-state screening experiments. Both polymorphic forms were characterized by single crystal X-ray structure analysis (SXRD), powder X-ray diffraction (PXRD), dynamic vapor sorption (DVS) and thermal analysis (TGA and DSC) as well. It has been found that the Forms I and II are of conformational polymorph with the main conformational difference around ethylsulfonyl group. Form II possesses lower hygroscopicity and better solubility compared with that of Form I, indicating Form II could be an alternate solid form for formulation development.