文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
非溶血性
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES · 2024 · IF 7.7

Developing a multifunctional chitosan composite sponge for managing traumatic injuries

Zhicheng Liu,Hao Zhang,Huining Su,Yang Chen,Xunan Jing,Daquan Wang,Shaohui Li,Hao Guan,Lingjie Meng

Developing porous hemostatic sponges that are both biosafe and multifunctional remains a complex challenge. Conventional hemostatic techniques often fall short in managing bleeding effectively, leading to severe critical cases such as suboptimal hemostasis, increased infection risk, and complications arising from profuse bleeding. To address these deficits, our study introduces a novel multifunctional nanocomposite sponge that synergistically incorporates chitosan (CS), cellulose (Cel), graphene oxide (GO), and silver (Ag) nanoparticles. The resulting CS/Cel/GO/Ag developed demonstrates a swelling rate exceeding 3000 %, an absorption rate of over 2100 %, and the lowest stress surpassing 20 kPa at an initial 80 % strain. In vitro analyses reveal that the CS/Cel/GO/Ag sponge has excellent cytocompatibility, non-hemolytic nature, and competence in blood cell adherence and bacterial inhibition. In vivo evaluations further demonstrate that compared to conventional hemostatic methods, the sponge substantially enhances hemostatic efficacy, as evidenced by the marked reductions in clotting times and diminished blood loss compared to conventional hemostatic methods. Specifically, the test results of the CS/Cel/GO/Ag sponge across three different models are as follows: for the rat tail amputation model, the clotting time was 99 s, while blood loss was 222 mg; for the rat liver injury model, the clotting time was 129 s. while blood loss was 812 mg; for the rat femoral artery laceration model, the clotting time was 96 s, while blood loss was 758 mg. The compelling attributes of the CS/Cel/GO/Ag sponges position them as a promising solution for the acute management of bleeding. Their excellent performance indicates they have potential role to play in trauma care.

CAS / MDL: 9004-32-4 25952-53-8
研究领域: 材料科学 · 生物医学工程 · 止血 · 纳米技术 · 组织工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。