文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
预冲洗
CHEMOSPHERE · 2020 · IF 5.778

Has the formation of disinfection by-products been overestimated? Membrane leakage from syringe filter heads serves as unexpected precursors

Tian Ou,Chao Fang,Shunke Ding,Tiantao Zhao,Shaogang Liu,Zhenxun Yu,Wenhai Chu

Syringe filters are widely used for sample pretreatments in laboratories. This study found that, surprisingly, these filters can leak dissolved organic carbon (DOC) that can potentially serve as precursors of disinfection by-products (DBPs). Nine common types of syringe filters were assessed. The results showed that the DOC of ultrapure water increased after syringe filtration. The DOC shed from filter membranes was characterized, whose spectra showed that the main compounds exhibited a low apparent molecular weight . Five classes of DBPs were investigated including trihalomethanes, haloacetaldehydes, haloacetonitriles, haloacetamides and halonitromethanes, among which trichloromethane (TCM), dichloroacetaldehyde (DCAL), trichloroacetaldehyde (TCAL), dichloroacetonitrile (DCAN), and trichloronitromethane (TCNM) were principally detected. The DBP formation was affected by chlorination time and membrane types. In general, the use of the poly vinylidene fluoride membrane resulted in the highest formation of TCM and TCAL, whereas nylon and mixed cellulose esters membranes contributed significantly to the formation of DCAN and TCNM, respectively. The shedding DOC and the formation of TCM, DCAL and TCAL from filter membranes were mitigated effectively by pre-washing; however, the contribution of membrane leakage to DCAN and TCNM formation was still notable, even with a pre-wash volume of 50 mL. When unwashed syringe filters were used for a real water sample, the DBP formation increased by up to 73.2% compared to the pre-washed ones; particularly for TCNM it was always over 15%. Therefore, for better quality control in laboratories, more attention should be paid to the syringe filters during sample pre-treatments, particularly when DBP formation is being investigated.

CAS / MDL: 7681-52-9
研究领域: 环境科学 · 公共卫生
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。