文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数303个

设置提升方向
鲁米诺
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2020 · IF 3.807

Electrochemiluminescence imaging of latent fingerprints by electropolymerized luminol

Shujie Hu,Zhiyuan Cao,Lin Zhou,Rongliang Ma,Bin Su

An efficient method has been developed for visualizing latent fingerprints by spatially selective electropolymerization of luminol on the ITO electrode. The fingerprint deposited on the electrode surface functions as a mask so that polyluminol is formed on the bare electrode surface. Therefore, electrochemiluminescence is only generated between the ridges of fingerprint, eventually yielding a negative ECL image. This method is easy to operate and safe to examiners. In addition, the second- and third-level details of fingerprints can be well resolved, indicating the potential application for personal identification and forensic investigation.

CAS / MDL: 521-31-3 77-86-1
研究领域: 法医学 · 分析化学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ChemistrySelect · 2023 ·Vol. 8 ·期 5 ·e202204363 · IF 2.1

A Signal Amplification Strategy Using ATP as a Co-Reaction Accelerator for the Electrochemiluminescence of Ru(bpy)32+/HEPES System and Detection of Iodide Anions**

Tingting Xu,Panpan Xu,Guilin Xu,Mengyao Liu,Yinggui Zhu

Graphical In the study, Ru(bpy) 3 2+ was used as the luminophore, HEPES buffer was served as the co-reactant, and ATP was added to the system to amplify the luminous signal. It was speculated that ATP acts as an co-reaction accelerator to promote the oxidation of HEPES to HEPES + ⋅, more HEPES⋅ can be generated, which then reacts with oxidized Ru(bpy) 3 3+ to emit stronger ECL signals. Moreover, I - consumes ATP, Ru(bpy) 3 2+ , and HEPES, leading to a decrease in ECL signal. Adenosine triphosphate is an important biological molecule that provides energy and substrate for various cellular biochemical processes,it's ubiquitous in our lives. In this work, a novel electrochemiluminescence (ECL) sensor composed of Ru(bpy) 3 2+ , 2-[4-(2-hydroxyethyl)piperazin-1-yl] ethanesulfonic acid (HEPES) and adenosine 5’-triphosphate disodium salt (ATP) was developed for the first time. In this ECL system, Ru(bpy) 3 2+ was used as the luminophore, HEPES buffer was served as the co-reactant, and ATP was added to the system to amplify the luminous signal to investigate the ECL behavior. Through fluorescence spectroscopy, ECL spectroscopy, and cyclic voltammetry (CV), it can be hypothesized that the possible ECL mechanism is that ATP acts as an advanced co-reaction promoter to accelerate the oxidation of HEPES to HEPES + ⋅, more HEPES⋅ can be generated, which then reacts with oxidized Ru(bpy) 3 3+ to emit stronger ECL signals. Subsequently, the influence of the ATP concentrations and the CV scanning speed was investaged. Moreover, it was observed that I − could quench the ECL intensity, the linear relationship range of I − concentration is from 10 −3 to 10 −6 m , the limit of detection is 3.7×10 −8 m (signal/noise=3), therefore, a new, highly sensitive, and selective ECL approach for I − detection was created.

CAS / MDL: 7681-11-0 50525-27-4
研究领域: 分析化学 · 生物化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2022 · IF 4.831

A miniature chemiluminescence spectrometric system induced by atmosphere microplasma jet to avoid using hydrogen peroxide and catalyst

Han Zhou,Yi Cai,Min Zhang,Wei Li,Yong Zhao

A miniature luminol chemiluminescence system based on atmosphere microplasma is proposed for detection without any catalysts. In our research, atmosphere microplasma jet is employed to oxidize luminol and produce chemiluminescence instead of H 2 O 2 . The transport of OH radicals to the plasma-liquid interface and induce the chemiluminescence. The weight of the system is only 3.6 kg (including a 1.2 kg laptop), and the power consumption of the microplasma is only 0.045 W. The mechanism of luminol chemiluminiscence induced by microplasma jet and generation of microplasma jet are investigated in this study. A 1 mL sample solution is sufficient for trace 3-NPA determination within an analysis time of 6 min. In the range of 0.03–10 mg L −1 , 3-NPA can be quantitatively analyzed along with a detection limit of 0.008 mg L −1 . In addition, the proposed system is employed for real-world samples detection, including water samples, brown sugar and tainted sugarcane, which demonstrates the reliability and practical feasibility of the detection method.

CAS / MDL: 521-31-3
研究领域: 分析化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Fundamental Research · 2021 · IF 0

Deciphering electrochemiluminescence generation from luminol and hydrogen peroxide by imaging light emitting layer

Ping Zhou,Shujie Hu,Weiliang Guo,Bin Su

Electrochemiluminescence (ECL) of luminol is a luminescence process that proceeds in the presence of reactive oxygen species (e.g. hydrogen peroxide (H 2 O 2 )) at a suitable electrode potential, the reaction mechanism of which is complicated and remains ambiguous. In this work, we report a visualization approach for measuring the thickness of the ECL layer (TEL) of the luminol/H 2 O 2 system to decipher the reaction process by combined use of the microtube electrode, ECL microscopy, and finite element simulations. With the increase of solution pH, the ECL image captured with the microtube electrode tends to vary from spot to ring, corresponding to the decrease of TEL from >9.1 μm to ca. 4.3 μm. We propose that different intermediates are involved in the course of ECL reaction. At a low pH (e.g. pH < 9), a relatively large TEL is most likely determined by the diffusion of oxidized and deprotonated luminol intermediate that is neutral and has a long lifetime. While at a high pH (e.g. pH in the range of 10 to 12), the ECL reaction is controlled by short-lived radical intermediates of both luminol and superoxide anion. The proposed mechanism is proved theoretically by finite element simulations and experimentally by the apparent effect of concentration ratio of luminol/H 2 O 2 .

研究领域: 分析化学 · 电化学
✓ 已验证 产品关联 DOI
查看原文 查看 PubMed
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY · 2022 · IF 5.141

Ascorbic acid as an alternative coreactant for luminol reaction and sensitive chemiluminescence determination of ascorbic acid in soft drinks

Hong Li,Yang Zhou,Jianxiu Du

Ascorbic acid can serve as an efficient coreactant for luminol chemiluminescence (CL) reaction. An observable CL emission is produced when mixing ascorbic acid with luminol in an alkaline condition. The CL signal is further dramatically enhanced by cobalt(II) ions. This CL system was exploited as a new method for direct determination of ascorbic acid with a flow injection mode. A good linear response is acquired between the CL signal and ascorbic acid concentration in 5.0–1000.0 ng/mL range with a detection limit of 1.3 ng/mL. The relative standard deviations are 2.3% for intra–day (n = 11) and 3.7% for inter–day (n = 3) by parallel determination of 0.5 μg/mL ascorbic acid solution. The method has good selectivity for ascorbic acid since no obvious responses are observed for a variety of inorganic ions and biological substances. The practicability of the method has been demonstrated by the analysis of ascorbic acid in some soft drinks.

研究领域: 分析化学 · 食品科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2018 · IF 6.042

Chemiluminescence of Lucigenin/Riboflavin and Its Application for Selective and Sensitive Dopamine Detection

Yixiang Lan,Fan Yuan,Tadesse Haile Fereja,Chao Wang,Baohua Lou,Jianping Li,Guobao Xu

Lucigenin-riboflavin chemiluminescence is reported for the first time. Moreover, most dopamine chemiluminescence (CL) detection methods are based on the quenching of CL by dopamine. In contrast, we find that dopamine can significantly enhance lucigenin/riboflavin CL and establish a highly sensitive turn-on method for dopamine detection based on the enhancement of lucigenin/riboflavin CL. Under the optimal conditions, the CL intensity of the lucigenin/riboflavin system increased linearly with the concentration of dopamine in the range of 0.0056–55.56 μM, and the limit of detection is 1.87 nM.

CAS / MDL: 61-76-7
研究领域: 分析化学 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2022 ·Vol. 46 ·期 9 ·4156-4161 · IF 3.925

Chemiluminescence “turn-on” detection of tyrosinase activity via in situ generation of dopamine based on a lucigenin and riboflavin system

Yi Wang,Chengpei Du,Ze Liu,Kanglin Pei,Yan Zhang,Wenjing Qi

A lucigenin and riboflavin chemiluminescence system was utilized for the first time to achieve the “turn-on” detection of tyrosinase activity via an in situ reaction between tyrosinase and tyramine to generate dopamine. Tyramine is the model substrate of tyrosinase and dopamine is the product. Since dopamine can enhance the chemiluminescence of the lucigenin and riboflavin system, the chemiluminescence of lucigenin and riboflavin can be enhanced in the presence of both tyramine and tyrosinase. In the presence of 6.0 U mL−1 tyrosinase, the chemiluminescence intensity was nearly 10 times higher than that of lucigenin, riboflavin and tyramine mixtures. Therefore, this method has been applied in the chemiluminescence “turn-on” detection of tyrosinase activity in the range of 0.1–8.0 U mL−1 with the limit of detection (LOD) of 0.028 U mL−1. This overall process of sensing tyrosinase activity took nearly 30 min. Moreover, it had high selectivity in the chemiluminescence “turn-on” detection of tyrosinase activity towards other enzymes, such as glucose oxidase, lysozyme, trypsin or alkaline phosphatase. When 1.0, 2.0 and 5.0 U mL−1 tyrosinase were added to the diluted serum samples, recoveries were in the range of 100.2%–104.1%. This indicates that this method for the chemiluminescence “turn-on” detection of tyrosinase activity has high sensitivity, selectivity, accuracy and fast response time.

研究领域: 分析化学 · 生物化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2022 · IF 9.231

An ingenious turn-on ratiometric fluorescence sensor for sensitive and visual detection of tetracyclines

Kairong Yang,Pei Jia,Jinjie Hou,Shuang Zhao,Li Wang

To achieve facile and rapid detection of tetracyclines (TCs), herein, we fabricated an ingenious turn-on ratiometric fluorescence sensor (Ru@ZIF-8) based on embedding red-emitting Ru(bpy) 3 2+ into zeolitic imidazolate framework-8 (ZIF-8). With the introduction of TCs, Ru@ZIF-8 system held the impervious red fluorescence, and generated green fluorescence which originated from the interaction between ZIF-8 and TCs, thereby achieving ratiometric fluorescence strategy through turn-on response signal and stable reference signal. Moreover, the ratiometric response accompanied discernible color change from red to green-yellow, which facilitated detection by naked eyes. The developed sensor exhibited prominent specificity and sensitivity, with detection limits of 2.4, 4.2, 1.6 and 7.2 nM for tetracycline, chlortetracycline , oxytetracycline and doxycycline , respectively. In addition, the satisfactory recoveries were obtained during detecting TCs in drink water, milk and beef, and the test paper-based sensor was successfully applied in real-time visual detection of TCs. All results indicated the feasibility and potential application of Ru@ZIF-8.

研究领域: 分析化学 · 环境科学 · 生物医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTROANALYTICAL CHEMISTRY · 2023 · IF 4.5

Inhibiting effect of graphdiyne on Ru(bpy)32+ ECL and its application in drug detection based on the host–guest interaction of cucurbit[8]uril

Haifeng Yao,Yahui Zhang,Yongping Dong,Mingfu Ye

Graphdiyne (GDY) is considered as another promising carbon material in biosensing field. However, the application of GDY in ECL sensing is in its infancy stage, and different roles of GDY are urgent to be discovered. In this work, strong anodic Ru(bpy) 3 2+ electrochemiluminescence (ECL) was obtained at a cucurbit[8]uril (Q[8]) modified electrode. Although GDY exhibited electrocatalytic effect on the oxidation of Ru(bpy) 3 2+ , an apparent inhibiting effect of GDY on the ECL signal was observed due to the energy transfer. An “on-off-on” mode ECL sensor was fabricated to detect pancuronium (PMD) based on the competitive host–guest interaction between ferrocene (Fc), PMD and Q[8]. Fc modified single-stranded DNA was immobilized onto the surface of GDY, which could be attached onto the electrode through the interaction between Fc and Q[8]. The quenching effect of GDY could apparently decrease ECL signal. PMD exhibited stronger combining ability with Q[8] than Fc, and could replace Fc from the cavity of Q[8], leading to the recovery of ECL signal. The variation of ECL intensity changed linearly with the PMD concentration in the range of 10 nM to 50 μM with a detection limit of 5 nM (3σ). The proposed sensor has high sensitivity, outstanding specificity and accuracy, indicating that GDY has promising potential application in ECL sensing field based on its inhibiting effect.

研究领域: 分析化学 · 生物传感 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
LUMINESCENCE · 2019 ·Vol. 34 ·期 7 ·673-679 · IF 1.691

Flow-injection chemiluminescence of the luminol–potassium periodate system enhanced by TGA–capped CdTe quantum dots for the determination of theophylline

Min Zhou,Qiqi Chen,Ailian Wang,Juanhua Li,Yongjun Ma

The chemiluminescence (CL) behaviour of the luminol–potassium periodate system enhanced by CdTe quantum dots capped with thioglycolic acid (TGA–CdTe QDs) was studied using kinetic experiments, CL spectra, UV–vis absorption spectra and fluorescence spectra. The production of oxygen-containing reactant intermediates (O 2 •− and OH • ) in the present CL system was verified by CL. The possible CL mechanism was discussed in detail. Furthermore, theophylline (THP) was determined based on its enhancement of the CL intensity of the CdTe QDs–luminol–potassium periodate system coupled with a flow-injection technique. Under these optimized conditions, the linear range was found to be from 1.0 × 10 −8 to 1.0 × 10 −5 g/mL with a detection limit of 2.8 × 10 −9 g/mL (3σ). The recoveries for the determination of THP in tablets were from 98.2 to 99.6%.

CAS / MDL: 521-31-3
研究领域: 分析化学 · 药学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2012 · IF 3.898

Ultrasensitive detection of carcinoembryonic antigen based on electrochemiluminescence quenching of Ru(bpy)32+ by quantum dots

Tingting Hao,Zhiyong Guo,Shuping Du,Lili Shi

An ultrasensitive electrochemiluminescence (ECL) immunosensor for the detection of carcinoembryonic antigen (CEA) in serum and saliva was developed. Ru(bpy) 3 2+ -graphene-Nafion composite was first coated on the glassy carbon electrode surface in this ECL immunosensor. The sandwich-type immunoreactions between the first antibody and the second antibody bridged the donors Ru(bpy) 3 2+ and acceptors QDs , which led to the occurrence of ECL quenching of Ru(bpy) 3 2+ by QDs . Based on the efficient ECL quenching, ultrasensitive CEA detection was realized. Under optimal conditions, the ECL signal depended linearly on the logarithm of the CEA concentration within a range from 0.005 to 0.5   pg/mL, and the detection limit of CEA was 0.002   pg/mL. Moreover, the proposed ECL immunosensor provides a stable, specific, and highly sensitive immunoassay protocol for CEA detection at very low levels, which might hold a promise for clinical application.

研究领域: 分析化学 · 生物医学工程
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL BIOCHEMISTRY · 2025 · IF 2.5

Sensitive electrochemiluminescent detection of hydroquinone using silver/luminol-functionalized carbon microspheres

Hui Zhang,Ziqi Wang,Yahui Ji,Junfeng Li,Feifei Chen,Fangxin Du,Gen Liu

The detection of organic pollutants in water was deemed critical for safeguarding aquatic ecosystems, maintaining human health, and upholding water quality standards. In this study, a novel electrochemiluminescence (ECL) sensor was proposed for the sensitive detection of hydroquinone (HQ) in lake water, utilizing a glassy carbon electrode (GCE) modified with silver/luminol-functionalized carbon microspheres (GCE/CM@Ag/Lu). Due to the consumption of H 2 O 2 by HQ, the ECL signal was attenuated, enabling the quantitative detection of HQ. Under optimized conditions, the linear range for HQ ranged from 1.0 × 10 −4 –1.0 × 10 −10  mol L −1 , with a limit of detection (LOD) of 3.3 × 10 −11  mol L −1  (S/N = 3). The proposed ECL sensor shows promising potential to open new avenues for water quality assessment.

CAS / MDL: 103-90-2 79-08-3 50-99-7
研究领域: 环境科学 · 分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。