文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
2-羟基雌酮
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS · 2022 · IF 3.571

Establishment and validation of a sensitive LC-MS/MS method for quantification of urinary estrogens in women with gestational diabetes mellitus

Xiaoli Zhang,Na Yang,Min Wang,JiaJia Ge,Huaijun Zhu,Jun He,Weihong Ge

Gestational diabetes mellitus (GDM) is not only a threat to the health of pregnant women, but also has profound effects on the health of offspring. Studies have shown that the imbalance of estrogen metabolism is associated with an increased risk of GDM. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established and validated for simultaneous quantification of thirteen estrogens in the urine of GDM women, including estrone (E1), estradiol (E2), estriol (E3), and their hydroxylated and methylated metabolites. The method was achieved on a Waters CORTECS C18 column (2.1 mm × 150 mm, 1.6 µm) within 8.5 min. The linear range of thirteen estrogens in urine was 2–1000 pg·mL −1 . Both intra- and inter-day precision for each analyte were less than 15%, with accuracies ranging from 8.3% to 7.3%. The extraction recoveries rate were between 86% and 111%, and stability verification results met the requirements for determination of biological samples. The results suggested that the concentrations of estrogens in all urine samples range from 0.08 to 134.06 (pg·mg −1 creatinine). The mean levels of E1, E2 and most estrogen metabolites in the urine of GDM women were higher than those in healthy pregnant women. Notably, the mean level of 2-hydroxyestrone (2-OHE1) in GDM women was 13.2-fold lower than that in healthy pregnant women. The types of estrogens with the highest mean levels in the urine of GDM and healthy pregnant women were obviously different, which are 2-methoxyestrone (2MeOE1) and E3, respectively. Our results demonstrated that this specific and sensitive method is suitable for quantifying estrogens in human urine and could provide support for further research on estrogen-related pathological mechanisms in GDM and other diseases.

研究领域: 医学 · 内分泌学 · 分析化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。