文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
223Ra
Nanomedicine · 2024 · IF 4.7

Design and in vitro evaluation of 223Ra/99mTc-loaded spherical nano-hydroxyapatite in bone tumor therapy

Yumei Wang,Yue Zhou,Dongliang Zhai,Hao Deng,Xiaoliang Chen

Aim: Nano-hydroxyapatite (nHA) is a good nanocarrier to load 223Ra, but the low specific activity (sp.act.) of 223Ra@nHA limits its application in medicine. Methods: We proposed a method for preparing nHA using PEG as a template, which significantly increases the sp.act of 223Ra@nHA and a new method to loaded 99mTc for in vivo tracking. Results: The nHA synthesized using PEG as a template was associated with higher sp.act for 223Ra in comparison to nHA with identical particle size and without PEG. The nHA load 99mTc-MDP was associated with higher labeling rate and stability in comparison to 99mTc. Conclusion: All these findings suggest that using PEG as a template and 99mTc-MDP could be the most effective of synthetic 223Ra/99mTc@nHA.

CAS / MDL: 7772-99-8
研究领域: 纳米技术 · 放射药学 · 癌症治疗 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY · 2026 · IF 1.7

Optimized ion-chromatographic method for determining 226Ra in aerosols using 223Ra as a tracer

Xu Ping,Wu Qingbiao,Li Yemian,Zhuang Sixuan,Wang Yufei,Zhu Zuolong,Li Lun,Ma Yinglin

This study presents an ion-chromatographic method for determining 226 Ra in aerosol samples using 223 Ra as a radiochemical yield tracer. A purified 227 Ac– 223 Ra tracer solution was prepared from certified uranium–radium equilibrium material and applied to optimize single-column chromatographic separation of radium on AG 50W resin with CyDTA eluents. The procedure enables accurate quantification of trace 226 Ra in aerosol filters with low minimum detectable activity and reliable chemical recoveries. For spiked samples containing 226 Ra, recoveries ranged from about 50%–80% with relative deviations below 5%, and an MDA of approximately 2 mBq was achieved for 24 h counting at the 95% confidence level. The optimized separation scheme is suitable for routine environmental monitoring of NORM-bearing aerosols and can also serve as a pre-concentration and purification step prior to ICP-MS-based 226 Ra analysis.

✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。