4-meso-UiO-66
MICROCHIMICA ACTA · 2024 ·Vol. 191 ·期 4 ·1-13 · IF 5.3

Electrospun of functionalized mesoporous UiO-66 as the selective coating of solid phase microextraction Arrow for the determination of nine alkylphenols

Yang Peixun,Zhu Xiaoyan,Lan Hangzhen,Wu Yichun,Pan Daodong

A solid-phase microextraction (SPME) Arrow and high-performance liquid chromatography-UV detector (HPLC-UV, detection at 225 nm) based method was developed for the selective determination of nine alkylphenols (APs) in milk. The functionalized mesoporous UiO-66 (4-meso-UiO-66) was utilized as the new coating material, which was synthesized by post-modification of pore-expanded UiO-66-NH 2 by an esterification reaction with 4-pentylbenzoic acid. It was fully characterized by X-ray photoelectron spectroscopy (XPS), fourier transformation infrared spectrometry, nitrogen sorption-desorption test, scanning electron microscopy, transmission electron microscopy, and X-ray diffractometer. The characterization results showed the ester groups and benzene rings were introduced into the 4-meso-UiO-66, and the mesoporous structure was predominant in the 4-meso-UiO-66. The extraction mechanism of 4-meso-UiO-66 to APs is the synergistic effect of Zr-O electrostatic interaction and the size exclusion effect resulting from XPS, selectivity test, and nitrogen sorption-desorption test. The electrospinning technique was utilized to fabricate the 4-meso-UiO-66 coated SPME Arrow and polyacrylonitrile (PAN) was used as the adhesive. The mass rate of 4-meso-UiO-66 to PAN and the electrospinning time were evaluated. The extraction and desorption parameters were also studied. The linear range of this method was 0.2–1000 μg L –1 with a coefficient of determination greater than 0.9989 under the optimal conditions. The detection limits were 0.05–1 μg L –1 , the inter-day and intra-day precision (RSD) were 2.8–11.5%, and the recovery was 83.6%–112%. The reusability study showed that the extraction performance of this new SPME Arrow could be maintained after 80 adsorption-desorption cycles. This method showed excellent applicability for the selective determination of APs in milk. Graphical abstract

研究领域: 分析化学 · 环境科学
✓ 已验证 DOI PubMed 高影响因子