文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

4 项

设置提升方向
5-HIAA
MICROPOROUS AND MESOPOROUS MATERIALS · 2020 · IF 4.551

Loading carboxyfluorescein into porous SiO2 spheres and UCNPs-cored porous SiO2 spheres: Emission turn-on sensing with a warning signal for tumor-biomarker 5-HIAA urine test

Di Wang,Erjun Sun

In this paper, a sensing probe (denoted as CFE) for tumor-biomarker 5-hydroxyindoleacetic acid (5-HIAA) was firstly synthesized. Its sensing mechanism was confirmed as the recovery of fluorescein structure via an ester-exchange reaction, accompanied with emission turn on effect towards 5-HIAA. To improve photostability and minimize self-quenching/aggregation of CFE molecules, they were loaded into silica based MCM-41 spheres and UCNPs-cored (up-conversion nanoparticles) MCM-41 spheres. Corresponding composite samples, denoted as CFE@MCM-41 and CFE@MCM-41@UCNPs, were carefully discussed to confirm their structure, including XRD , N 2 adsorption and desorption, SEM/TEM and TGA . The energy transfer from secondary excitation source UCNPs to probe CFE was confirmed by Forester radius calculation and emission lifetime comparison. Sensing performance of CFE@MCM-41 and CFE@MCM-41@UCNPs were finally discussed in detail. They showed emission turn on effect towards 5-HIAA with good selectivity. CFE@MCM-41 showed linear response, while CFE@MCM-41@UCNPs showed exponential response, resulting in a warning signal when analyte concentration was higher than a critical level. The reason for this exponential response was discussed and explained. Their practical sensing result for human urine test was compared to HLPC method and literature methods, which confirmed the promising result of CFE@MCM-41 and CFE@MCM-41@UCNPs.

研究领域: 生物化学 · 医学诊断 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2025 · IF 5.1

A ratiometric fluorescent probe for a smartphone-based dual-emission carbon dot fluorescence sensor for the rapid detection of 5-HIAA

Yuying Han,Xingyu Hou,Yali Li,Xiaopeng Yang,Xue Sun,Xinxin Bian,Na Sun,Yuguang Lv,Lixin Ding,Ze Li

This study utilized Panax notoginseng leaves carbon dots (PN-CDs) with red and blue fluorescence to detect 5-hydroxyindoleacetic acid (5-HIAA). It is a straightforward one-pot hydrothermal technique using Panax ginseng leaves to synthesize these CDs. Under 400 nm excitation, 5-HIAA decreases the fluorescence intensity at 670 nm while enhancing the fluorescence intensity at 420 nm. The fluorescence intensity ratio (F 670 /F 420 ) exhibited a significant linear relationship over the 5-HIAA concentration range of 0–100 μM. Notably, smartphones could capture the observable color change of the PN-CDs under 365 nm UV exposure and perform RGB (red/green/blue) analysis for color quantification using the smartphone’s software. The detection limit for its fluorescence detection was determined to be 0.023 μM, whereas that of mobile phone detection was 0.36 μM. This study proposes a novel platform combining fluorescence sensing and cell phone technology, facilitating real-time analysis of 5-HIAA levels in human urine.

研究领域: 生物化学 · 医学检测 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2025 · IF 6.7

Homogeneous Luminescence Detection Based on Lanthanide Coordination Compound

Xin Tong,Zicheng Wang,Lina Zhao,Kai Wang,Yuxin Li

Lanthanide coordination compounds (LnCC), as excellent luminophores, exhibit ultrasensitive responses to the structural details of coordination environments, providing an effective platform for chemical and biomedical detection. Due to the overtones of molecular vibrations in water that cause luminescence quenching, LnCC-based sensors are typically used in heterogeneous systems, where the compounds are dispersed as solid nanoparticles in aqueous solvents. However, this reduces sensor stability, affecting sensitivity and selectivity, and complicates mechanistic analysis. In this work, we developed homogeneous luminescence detection techniques using LnCC and investigated the underlying chemical mechanisms. The Eu-DPA coordination compound was synthesized as a homogeneous detector with good water solubility (140.3 mg/g) and excellent luminescence (92.49% quantum efficiency and >2 ms lifetime at 1 g/L concentration) via multifaceted sonication. Thanks to its homogeneous nature, the sensor achieved high sensitivity, selectivity, and stability for detecting the carcinoid marker 5-hydroxyindoleacetic acid (5-HIAA) in water, plasma, and urine. Eu-DPA exposes numerous pyridine carboxylate oxygen sites that form hydrogen bonds with the amino groups in 5-HIAA. Transient Absorption Spectroscopy (TAS) and Time-Resolved Luminescence Spectroscopy (TRES) further confirm that electrostatic interactions between the hydrogen-bonding sites significantly influence the energy transfer process, as evidenced by changes in luminescence behavior. This work not only addresses the challenge of balancing water solubility and efficient luminescence in lanthanide complexes but also offers new insights into the development of practical biomedical luminescence sensors.

CAS / MDL: 499-83-2
研究领域: 无机化学 · 分析化学 · 生物无机化学 · 传感器 · 生物医学检测 · 配位化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY · 2022 · IF 5.201

Baicalein exerts anxiolytic and antinociceptive effects in a mouse model of posttraumatic stress disorder: Involvement of the serotonergic system and spinal delta-opioid receptors

Lina Ruan,Kaiyu Guan,Yue Wang,Ming Gu,Yue Chen,Lisha Cai,Ruixuan Ye,Zhengwei Huang,Anqi Guo,Zhengkang Su,Xi Li,Jianchun Pan

Post-traumatic stress disorder (PTSD) is a serious mental disease featured by a stress dysfunction that occurs after an individual has faced intense mental stress, often accompanied by anxiety and chronic pain. Currently, the mainstream drug for PTSD is serotonin reuptake inhibitors (SSRIs), however, their pain management for patients is limited. Baicalein , a Chinese traditional herbal medicine, has shown promising results in treating anxiety, depression, and pain. In this study, we found that baicalein may alleviate single prolonged stress (SPS)-induced PTSD-like behaviors in mice without altering baseline nociceptive sensitivity or activity. Meanwhile, baicalein increased the noradrenaline (NE) and serotonin (5-HT) content and decreased the ratio of 5-hydroxyindoleacetic acid (5-HIAA)/5-HT by inhibiting the activity of monoamine oxidase A (MAO-A) in SPS-induce mice. The anxiolytic and antinociceptive effects induced by baicalein were totally abolished by 5-HT depleting agents. Moreover, the anxiolytic effects of baicalein could be abolished by the 5-HT 1A receptor antagonist WAY-100635, and the analgesic effects could be abolished by delta-opioid receptor antagonists in the spinal. Taken together, our study provides compelling evidence that baicalein reversed anxiety-like behaviors and neuropathic pain in PTSD through serotonergic system and spinal delta-opioid receptors.

研究领域: 药理学 · 神经科学 · 精神病学 · 传统中药
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。