文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数13个

设置提升方向
ABEI
Journal of Analytical Science and Technology · 2021 ·Vol. 12 ·期 1 ·1-9 · IF 2.769

Determination of tyrosine by sodium fluorescein-enhanced ABEI–H2O2–horseradish peroxidase chemiluminescence

Dong Bin,Fan Qian,Li Ming,Huan Yanfu,Feng Guodong,Shan Hongyan,Fei Qiang

In this study, N-(4-aminobutyl)-N-ethylisoluminol (ABEI) was used as an energy donor, while sodium fluorescein was used as an enhancer and energy acceptor, which resulted in it producing resonance energy transfer and greatly increasing the strength of chemiluminiscence (CL). When horseradish peroxidase (HRP) is added, hydrogen peroxide (H2O2) will quickly separate into hydroxyl radicals (·OH) and superoxide ions (O2·−). If tyrosine (Tyr) is present in the system, the hydroxyl group on the benzene ring of Tyr robs ·OH and O2·− in the CL system, thereby reducing the intensity of CL. Based on this phenomenon, a luminescence system of ABEI and sodium fluorescein system was established to detect Tyr for the first time. This method has an ultra-low detection limit and a wide linear range, and is cheap and easy to operate. Under various optimal conditions, the linear range is from 3.0×10−8 to 3.0×10−5 mol/L, and the limit of detection is 2.4×10−8 mol/L. It has been successfully used in the detection of dairy products with satisfactory results.

研究领域: 生物化学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ELECTROCHIMICA ACTA · 2016 · IF 4.803

An electrochemiluminescence immunosensor based on ABEI and FCA functionalized Platinum@Copper hierarchical trigonal bipyramid nanoframes

Huiyun Yang,Haijun Wang,Chengyi Xiong,Yuting Liu,Ruo Yuan,Yaqin Chai

In this work, an electrochemiluminescence (ECL) immunosensor for ultrasensitive detection of mucin-1 (MUC1) was designed with N-(aminobutyl)-N-(ethylisoluminol) (ABEI) and host-guest inclusion functionalized Platinum@Copperhierarchicaltrigonalbipyramidnanoframes(Pt@Cu HNFs) as signal label. At First, Pt@Cu HNFs were prepared to load abundant amine-modified β-cyclodextrin (β-CD) and luminophore ABEI via Pt-N bond. Based on the effect of host-guest recognition, ferrocenecarboxylic acid (FCA) as a catalyst of ABEI-H 2 O 2 system was linked on the cavity of amine-modified β-CD to form nanocomposite of Pt@Cu HNFs-ABEI-(β-CD-FCA). Both Pt@Cu HNFs and FCA could catalyze H 2 O 2 decomposition, which significantly enhanced the ECL intensity of ABEI-H 2 O 2 system. Forthermore, simultaneously immobilizing ABEI and its catalyst FCA on Pt@Cu HNFs with good electrical conductivity could greatly increase the electron transfer efficiency in the ECL reaction, leading to a further signal amplification. Then, due to its good biocompatibility, large specific surface area and high luminous efficiency, the obtained Pt@Cu HNFs-ABEI-(β-CD-FCA) could act as an ideal nanocarrier of detection antibody (Ab 2 ). As a result, a desirable “signal-on” ECL immunosensor was proposed for the detection of MUC1 with a wide linear range from 1   ×   10 −5   ng   mL −1 to 10   ng   mL −1 and a relatively low detection limit of 3.3 fg mL −1 (S   N −1   =   3), making this approach hold great potential for protein analysis.

研究领域: 生物传感 · 分析化学 · 医学检测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2020 · IF 8.758

Novel Protease-Free Long-Lasting Chemiluminescence System Based on the Dox-ABEI Chimeric Magnetic DNA Hydrogel for Ultrasensitive Immunoassay

Haiping Wu,Min Zhao,Jia Li,Xiaoyan Zhou,Tiantian Yang,Dezhang Zhao,Ping Liu,Huangxian Ju,Wei Cheng,Shijia Ding

Most of chemiluminescence (CL) substrates exhibit the flash-type light emission. Therefore, the long-lasting CL system is always the crown in the field of CL-based analysis methodology. In this work, we constructed a Dox-ABEI chimeric magnetic DNA hydrogel (MDH) as a novel protease-free long-lasting CL reaction system. The functional MDH can transform flash-type ABEI/H2O2/CO2+ reaction into a glow-type CL system because of its block effect on delaying the diffusion rate of co-reactants, making the CL reaction gradually occur. More importantly, the functional MDH possessed the advantages of biocompatibility and controllability and could be well-designed to incorporate different biosensing strategies. Subsequently, we established a functional MDH-based long-lasting CL immunoassay system for ultrasensitive and highly specific detection of d-dimer and fibrin degradation products (FDPs). The designed CL immunoassay can detect d-dimer and FDP down to 53.7 and 31.6 fg/mL, respectively, with a wide line ranging from 100 fg/mL to 100 ng/mL, which was superior to the previously reported CL biosensing strategies. Moreover, benefiting from the magnetic separation of MDH and excellent CL performance, the developed immunoassaying method was successfully applied in the detection of clinical samples, which showed a close correlation with clinical reference technology. Thus, this functional MDH proved to be an excellent long-lasting CL system and a potential technical platform for clinical bioanalysis applications.

研究领域: 分析化学 · 生物化学 · 生物技术 · 临床化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
COLLOIDS AND SURFACES B-BIOINTERFACES · 2022 · IF 5.999

An electrochemiluminescence immunosensor based on ABEI-GO-AgNPs as a double-amplified luminophore for the ultra-sensitive detection of prostate-specific antigen

Zhi Luo,Dongmiao Qin,Yusheng Wu,Shuo Meng,Weiming Mo,Biyang Deng

A sandwich electrochemiluminescence (ECL) immunosensor based on an N-(4-aminobutyl)-N-ethylisoluminol-graphene oxide-Ag nanoparticle (ABEI-GO-AgNPs) complex and cysteine silver nanowires (AgCysNWs) was prepared to detect prostate-specific antigen (PSA). Our results showed that an ECL signal probe, ABEI-GO-AgNPs, with an ultrahigh specific surface area, favorable catalytic properties, and electrical conductivity was prepared by a one-step synthesis method. ABEI-GO-AgNPs with good biocompatibility immobilized secondary antibody (Ab 2 ) via Ag N bonds. Furthermore, AgCysNWs containing many –COOH groups were prepared and used to enrich primary antibody (Ab 1 ), which could be used as an affinity probe for the selective capture of PSA. Lastly, through layer-by-layer assembly, we established an ECL immunosensing platform for the sensitive detection of PSA. Under the optimized conditions, the designed ECL immunosensor showed promising sensitivity and selectivity for the detection of PSA in the linear range of 5.5 × 10 −7 –5.5 ng/mL, with a detection limit of 1.2 × 10 −7 ng/mL. The constructed ECL sensing platform possessed good specificity, reproducibility, and stability and could detect PSA in actual human serum samples.

研究领域: 分析化学 · 生物传感器 · 纳米技术 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF THE ELECTROCHEMICAL SOCIETY · 2019 ·Vol. 166 ·期 2 ·B49 · IF 3.12

ECL Biosensor for Sensitive Detection of Soybean Agglutinin Based on AuPt@C60 Nanoflowers Enhanced N-(aminobutyl)-N-(ethylisoluminol)

Di Liu,Fangxin Hu,Han Zhang,Cong Zhang,Shihong Chen

A sandwich electrochemiluminescence (ECL) biosensing system for soybean agglutinin (SBA) detection was developed with AuPt@C60 nanoflowers (AuPt@C60 NFs) as a novel co-reactant accelerator to enhance the performance of N-(aminobutyl)-N-(ethylisoluminol) (ABEI). In this strategy, nanoflower-liked AuPt@C60 complex served as a matrix for loading a large sum of ABEI and galactosamine (Gal) by Au-N and Pt-N bonds to achieve the nanocomposite Gal-ABEI-AuPt@C60 NFs. Dissolved oxygen was used as a co-reaction reagent, while AuPt@C60 complex acted as a co-reactant accelerator for dissolved oxygen to enhanced the ECL emission of ABEI. Gal, as an identifying element, was highly loaded by electrodeposited gold nanoparticles (Dp Au) on the electrode to recognize SBA, and further combine with Gal-ABEI-AuPt@C60 NFs to form a sandwich model. As a result, the proposed SBA biosensor exhibited a wide linear range from 1.0 ng·mL−1 to 5.0 μg·mL−1 and a low detection limit of 0.33 ng·mL−1. In addition, the biosensor displayed an excellent selectivity and an acceptable stability and reproducibility. The combination of AuPt@C60 NFs and ABEI provided a new ECL sensing platform without exogenous co-reactant.

研究领域: 生物传感器 · 分析化学 · 食品科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
FOOD CHEMISTRY · 2026 · IF 10.4

Cu-CDs/ABEI@Ag with peroxidase-like catalytic activity for chemiluminescence sensing of glyphosate residues in coffee

Qiulan Li,Jiahe Dai,Yaling Yang,Linqian Hou,Hong Li

In this study, an “off” signal chemiluminescence (CL) sensor was designed for the detection of glyphosate (Gly) based on Cu-CDs/ABEI@Ag as CL enhancers. Copper-doped carbon dots (Cu-CDs) was synthesized through a sample microwave digestion approach, and AgNO 3 was reduced to silver nanoparticles (AgNPs) utilizing N-(4-aminobutyl)-N-ethylisoluminol (ABEI) and prepared Cu-CDs as mild reducing agents. The Cu-CDs and AgNPs demonstrated peroxidase (POD)-like properties, facilitating the breakdown of H 2 O 2 into reactive oxygen species (ROS) such as ∙OH, ∙O 2 − , and 1 O 2 to generate CL signal. By integrating ABEI into the catalyst system, the CL reagent became concentrated within the catalyst structure, minimizing the spatial separation between the catalyst and ABEI, thus amplifying the CL response. Notably, Gly can inhibit POD-like activity by interaction between Cu-CDs/ABEI@Ag and Gly, thus decrease the CL intensities produced from oxidation of ABEI. Based on this highly sensitive “off” response in CL, a CL nano-sensor was developed for Gly detection, achieving a detection limit of 3.87 μg/L. Furthermore, satisfactory spiked recovery rates (95.86–111.13%) were obtained in coffee samples, highlighting the sensor's promising applicability for on-site Gly monitoring.

✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Analytical Methods · 2016 ·Vol. 8 ·期 44 ·7929-7936 · IF 1.915

A chemiluminescent aptasensor for simultaneous detection of three antibiotics in milk

Liling Hao,Huajie Gu,Nuo Duan,Shijia Wu,Zhouping Wang

In this study, a highly sensitive and specific multiplex chemiluminescent method for the simultaneous detection of three antibiotics was fabricated. Thiolated hybridized complementary strand (cDNA) modified N-(4-aminobutyl)-N-ethylisoluminol (ABEI) functionalized flowerlike gold nanostructures (AuNFs) were used as signal probes. Oxytetracycline (OTC), tetracycline (TET) and kanamycin (Kana) aptamers that were fixed onto the bottom of microtiter plates were used as recognition molecules. Targets and signal probes can competitively combine with the fixed aptamers. Thus, OTC, TET and Kana can be simultaneously detected based on an ABEI–H2O2–P-iodophenol (PIP) steady-state chemiluminescence (CL) system and the CL intensity is related to the negative logarithm of the concentrations of OTC/TET/Kana, respectively. The ranges are 0.05 to 5 ng mL−1, 0.05 to 5 ng mL−1, and 0.005 to 0.5 ng mL−1, and the detection limits are 0.02, 0.02 and 0.002 ng mL−1 (S/N = 3), respectively. The capability of the bioassay in milk was also studied using the standard addition recovery method, and the results showed a good consistency with the ones that were obtained from a commercial ELISA method. Owing to the advantages of a simple operation procedure, and excellent selectivity and specificity, the proposed biosensor demonstrated great potential in the application of food safety and multiplex nanosensors.

研究领域: 分析化学 · 食品安全 · 纳米技术 · 生物传感器
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2023 ·Vol. 190 ·期 9 ·1-14 · IF 5.7

Dual-potential electrochemiluminescence cytosensor based on a metal-organic framework and ABEI-PEI-Au@AgNPs for the simultaneous determination of phosphatidylserine and epidermal growth factor receptors on an apoptotic cell surface

Mo Guichun,Qin Dongmiao,Wu Yusheng,Luo Zhi,Mo Keting,Deng Biyang

Abstract A new electrochemiluminescence (ECL) cytosensor is proposed for the simultaneous determination of phosphatidylserine (PS) and epidermal growth factor receptor (EGFR) based on the ECL signals of metal-organic framework-5 (MOF-5) loaded CdS quantum dots and N-(aminobutyl)-N-(ethylisoluminol)-polyethylenimine capped Au and Ag nanoparticles. Apoptosis promotes the exposure of PS and reduces the expression of EGFR in cell membranes. Two spatially resolved areas on dual-disk glassy carbon electrodes were designed to eliminate the interference from different ECL probes. Using HepG2 cells treated with resveratrol to induce apoptosis, the cytosensor exhibited high sensitivity, simplicity, and high reproducibility, demonstrating its potential in drug screening and rapid apoptotic cell detection. The strategy reported provides a promising platform for the highly sensitive cytosensing and convenient screening of clinically relevant anticancer drugs. Graphical Abstract

研究领域: 分析化学 · 生物医学工程 · 生物传感器 · 癌症研究
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2022 · IF 10.383

Chemiluminescent Two-Dimensional Metal–Organic Framework with Multiple Metal Catalytic Centers and Its Peroxidase-like Activity for Sensing of Small Molecules

Jue Wang,Chao Hu,Yi-sha Wang,Hua Cui

Two-dimensional (2D) porphyrin-based metal–organic frameworks (MOFs) hold great promise in a variety of areas with the merits of large lateral size and abundant functional groups. The chemiluminescent 2D MOF has rarely been reported. In this work, a chemiluminescence (CL) reagent and noble metal nanoparticle dual-functionalized 2D MOF (ABEI/AuNPs/CuTCPP) was developed through the surfactant-assisted and in situ synthetic growth method, exhibiting strong and stable CL property and outstanding peroxidase-mimicking activity. The special nanostructure of ABEI/AuNPs/CuTCPP endowed it with multi-catalytic routes in the CL reaction, which showed a unique pH-regulated and time-resolved CL kinetic curve. A CL mechanism with multi-catalytic centers has been proposed. AuNPs participated in the fast catalytic process and CuTCPP in the slow and strong catalytic reaction. Owing to the impressive structural features and intrinsic enzymatic tandem reaction from natural enzyme to artificial enzyme, a model biosensor was designed for the detection of small metabolic molecules. Employing choline as a model target, the proposed biosensor showed a highly sensitive response to choline in the linear range from 0.3 to 300 μM with a detection limit of 82.6 nM. Significantly, the strategy may be generalized to the monitoring of other biologically important compounds involved in the production of H2O2.

CAS / MDL: 76-05-1 290-37-9
研究领域: 材料科学 · 分析化学 · 纳米技术 · 生物传感器
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICA CHIMICA ACTA · 2021 · IF 6.558

Novel cobalt-based metal-organic frameworks with superior catalytic performance on N-(4-aminobutyl)-N-ethylisoluminol chemiluminescent reaction

Lvxia Zhang,Hui Ouyang,Dan Zhang,Zhifeng Fu

Novel cobalt-based metal-organic frameworks (Co MOFs) were synthesized by a facile “controlled synthesis” strategy. The MOFs displayed superior catalytic performance on the chemiluminescent (CL) reaction between N -(4-aminobutyl)- N -ethylisoluminol (ABEI) and H 2 O 2 . UV–vis absorption, CL spectrum, ESR, and radical scavenger experiments were conducted for clarifying the catalytic mechanism of Co MOFs. All results revealed that Co MOFs can accelerate decomposition of H 2 O 2 and production of OH • , O 2 • − as well as 1 O 2 radicals. The rapid reaction between these reactive oxygen species and ABEI resulted in the generation of ABEI-ox∗. The excited-state oxidation product emitted a very intensive CL signal with a maximal emission wavelength of 430 nm as it returned to the ground state. To explore their application potential in CL assay, Co MOFs were used as powerful CL reaction catalyst for establishing a very sensitive method for immunoassay of aflatoxin B 1 . The detection range was 0.05–60 ng mL −1 , and the limit of detection was 4.3 pg mL −1 . The result for detecting herbal medicine samples demonstrates the acceptable reliability of the Co MOFs-based CL immunoassay. The proof-of-principle work verifies the application potential of Co MOFs on boosting intensive CL signal, and meets the demand for high sensitivity in various bioassay fields.

研究领域: 分析化学 · 材料科学 · 生物化学 · 环境科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2024 · IF 6.7

A Three-Dimensional Electrochemiluminescence Sensor Integrated with Peptide Hydrogel for Detection of H2O2 Released from Different Subtypes of Breast Cancer Cells

Yunfan Zhou,Xue Wei,Jun Chen,Hanzhi Xiong,Dandan Sui,Xu Chen,Wensheng Yang

Breast cancer is a malignant tumor, with various subtypes showing different behaviors. Endogenous H2O2 is an important marker of tumor progression, which makes it important to study the relationship between breast cancer subtypes and H2O2 for pathogenesis and treatment strategies, but this has rarely been reported so far. In this work, we constructed a three-dimensional (3D) electrochemiluminescence (ECL) sensing platform for the detection of H2O2 released from two typical subtypes of breast cancer cells (MCF-7 cells for luminal A-type and MDA-MB-231 cells for three negative breast cancers, TNBCs). To adequately replicate the tumor microenvironment, the peptide hydrogel was introduced as a scaffold for 3D cell culture. The titanium foam (TF) was used as a 3D electrode to better match the 3D culture substrate. N-(4-Aminobutyl)-N-ethylisoluminol (ABEI) was selected as the ECL emitter and assembled into the peptide hydrogel by hydrogen bonding and π-stacking, which resulted in a stable and homogeneous distribution of ABEI along the hydrogel fibers. Furthermore, basic amino acids were introduced to provide alkaline microenvironment for ABEI. Therefore, ABEI exhibited high ECL efficiency, resulting in a high sensitivity with an ultralow detection limit of 0.023 nM (S/N = 3) for H2O2 of the proposed ECL biosensor. MCF-7 and MDA-MB-231 cells were cultured in a 3D peptide hydrogel/ABEI/TF electrode, respectively, and endogenous H2O2 was successfully monitored. A notably significant difference of H2O2 released between MDA-MB-231 cells and MCF-7 cells without stimulation but similar extra release with stimulation were observed. These findings may help understand the physiological mechanisms behind the various subtypes and reactive oxygen species (ROS)-related treatment for breast cancer.

CAS / MDL: 66612-29-1 7722-84-1
研究领域: 生物医学工程 · 癌症生物学 · 分析化学 · 细胞生物学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2020 · IF 6.785

Polymer-Encapsulated Cobalt/Gold Bimetallic Nanoclusters as Stimuli-Responsive Chemiluminescent Nanoprobes for Reactive Oxygen Species

Bingjie Gao,Mohammad A. Haghighatbin,Hua Cui

A stimuli-responsive chemiluminescent nanocomposite was developed based on bimetallic nanoclusters encapsulated in a reactive oxygen species (ROS)-responsive polymer for a highly sensitive determination of ROS (i.e., H2O2) in biological samples. Cobalt/gold bimetallic nanoclusters (GSH@Co–AuNCs) were synthesized using glutathione (GSH) as a reducing-cum-protecting reagent. The GSH-coated nanoclusters were covalently bound to N-(4-aminobutyl)-N-ethylisoluminol (ABEI) to form the GSH@Co–AuNCs–ABEI, which was further encapsulated in polymeric ROS-sensitive boronic ester modified dextran (Oxi-Dex) nanospheres through hydrophobic interactions. The stimulation of H2O2, as a model ROS, led to a sustainable structural cleavage of the Co–AuNCs–ABEI@Oxi-Dex nanocomposites and release of internal GSH@Co–AuNCs–ABEI, accompanied by intense chemiluminescence (CL). On this basis, an enzyme-free and reagent-free CL sensor was developed for a highly sensitive and selective determination of H2O2 with a detection limit of 35.8 pM in biological samples. It is of great application potential for the determination of ROS related to various diseases.

研究领域: 分析化学 · 纳米技术 · 生物化学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。