Unsaturated lipids play an essential role in living organisms, and their different isomers show significant functional differences. Therefore, in situ characterization of unsaturated lipids in tissues needs to be extended to isomer level. However, the exposure of tissue sections to an open environment for a long time may cause cell autolysis or corruption, and current unsaturated lipid imaging methods still face challenges in efficiency. This paper proposes an imaging method based on photoepoxidation coupled with air-flow-assisted desorption electrospray ionization mass spectrometry (AFADESI-MS) to rapidly realize the spatial characterization of unsaturated lipids at the isomer level. The technique has a fast response speed, high epoxide yield (>80%), and high diagnostic ion abundance. After 0.5 min of photoepoxidation, the derivation product yield ratio reached 24.6%. This method rapidly identified six glycerophospholipid isomers containing an 18:1 acyl chain in normal rat liver tissue. Then the imaging method was applied in nude mice lung cancer tissue and human thyroid cancer tissue, with only 3 min photoepoxidation. Results successfully characterized the location and range of unsaturated lipid isomers and revealed their enrichment in tumor tissue. In addition, the experiment shows that the variational trend of the ratio of unsaturated lipid isomers in different types of tumor samples is different. Based on the advantages of efficiency and convenience, this method is prospective for screening unsaturated lipid markers and pathological research of related diseases.
In recent years, the development of unsaturated lipid isomeric imaging based on the Paternò–Büchi (PB) reaction has improved significantly. However, research on this imaging method in ambient conditions needs to expand. In this paper, a method of PB reaction in the solid phase in ambient conditions is developed, which is combined with air-flow-assisted desorption electrospray ionisation mass spectrometry (AFADESI-MS) to achieve in situ imaging of lipids at an isomeric level. Experiments showed that the efficiency of the PB reaction was much higher when spraying the reagent solution than when sprinkling the reactant powder directly, and it was not lower than that in the liquid phase. This method can simplify the reaction conditions in the imaging process and can be applied to tissue section samples with only 10 min of pre-processing. The study successfully demonstrated the spatial distribution of unsaturated lipid isomers, and the isomeric ratio corresponded to the lesion areas in mouse brain cancer tissues. Due to its simple operation and performance in ambient conditions, this method may be useful for future studies on lipid isomers in tissues.