文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
AUC/MIC
Scientific Reports · 2025 ·Vol. 15 ·期 1 ·1-8 · IF 3.9

LC-MS/MS quantification of omadacycline in human plasma for therapeutic drug monitoring: method development and clinical application

Wang Yueyuan,Diao Zhipeng,Qu Yuchen,Fan Kai,Feng Chen,Lv Bo,Yu Yunli,Geng Zhou

Omadacycline, a third-generation tetracycline antibiotic, exhibits time-dependent pharmacokinetics. The ratio of the 24-hour area under the concentration-time curve to minimum inhibitory concentration (AUC 0−24 /MIC) serves as the primary pharmacokinetic/pharmacodynamic (PK/PD) index for omadacycline, demonstrating strong correlation with therapeutic efficacy, particularly in critically ill patient populations. To facilitate routine therapeutic drug monitoring (TDM) in clinical practice, a high-performance liquid chromatography - tandem mass spectrometry (HPLC-MS/MS) method was developed for quantification of omadacycline in human plasma. An Agilent 1260 series liquid chromatograph and an API 4000 triple tandem quadrupole mass spectrometer were used for the determination of omadacycline and endocannabinoids. The separation was performed on a Phenomenex KINETEX XB-C18 column (2.6 μm, 3 × 50 mm) with 0.1% formic acid-water and pure acetonitrile as the mobile phases. The LC-MS/MS separation was carried out using a gradient elution procedure at a flow rate of 0.4 mL/ min, and the total run time was 5 min. An electrospray ionization (ESI) was selected, and the detection ions of omadacycline and the internal standard (fexofenadine-d6) were determined by mass spectrometry scanning with multiple reaction monitoring (MRM) in positive ion mode as follows: m/z 557.4→453.4 and m/z 508.4→472.8, respectively. The established linear range (20-2000 ng/mL) effectively covers the plasma concentration range encountered in > 98% of clinical samples, making it suitable for routine therapeutic drug monitoring. The method demonstrated acceptable selectivity, recovery, and matrix effect. The results of intra-day precision and inter-day precision show that the relative standard deviation (RSD) is less than 10%, while the relative error (RE) is within ± 10.00%. In this study, we developed and validated a simple, sensitive and accurate method to quantify the concentration of omadacycline in human plasma using LC-MS/MS. This offers essential technical support for the rational clinical application of omadacycline.

研究领域: 药理学 · 分析化学 · 临床药理学 · 质谱分析 · 治疗药物监测
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。