文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
BSA微球
JOURNAL OF APPLIED POLYMER SCIENCE · 2011 ·Vol. 121 ·期 1 ·352-358 · IF 1.24

Preparation and characterization of BSA-loaded microspheres based on polyanhydrides

Yang Yu,Tingli Lu,Wen Zhao,Weiguang Sun,Tao Chen

A series of biodegradable PEG-containing polyanhydrides composed of sebacic acid, 1, 6-bis( p -carboxyphenoxy) hexane, and poly (ethylene glycol) (PEG) were used as matrix material for BSA-loaded microspheres. The effects of polymer composition on the microsphere size, entrapment efficiency, in vitro degradation, and in vitro protein release were studied. Microspheres in the size range of 0.8–10 μm were fabricated via a modified double emulsion method and were characterized using scanning electron microscopy. As the content or the molecular weight of PEG was increased in the copolymer, a proportional increase was found in the particle size and the efficiency of BSA entrapment. The in vitro degradation rate of particles could be controlled by varying the polymer composition, increasing as the PEG proportion increased. In vitro release studies of BSA from polyanhydride microspheres revealed that the increased amounts of PEG within microspheres could accelerate the release rate of protein. These studies indicate that the PEG-containing polyanhydrides hold potential for protein delivery applications. © 2011 Wiley Periodicals, Inc. J Appl Polym Sci, 2011

研究领域: 生物材料 · 药物递送
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICA CHIMICA ACTA · 2020 · IF 5.977

Au@BSA microspheres-luminol and a novel luminescent Zeolitic Imidazolate Framework were used for potential-resolved electrochemiluminescence to detect dual targets

Qihao Zhu,Weiran Mao,Chengli Zhang,Yuan Zhou,Zhiyong Tang,Chao Yu

Here, a novel electrochemiluminescence biosensor based on potential-resolved strategy was firstly prepared for the detection of dual targets α2,3-sialylated glycans and α2,6-sialylated glycans. This is the first time that Au@BSA microsphere was used to connect with luminol to enhance its ECL intensity, and it can generate ECL signals at positive potential. Zeolitic Imidazolate Framework-8 (ZIF-8) and Meso-tetra (4-carboxyphenyl) porphyrin (TCPP) were linked using a one-pot method to synthesize a novel luminescent ZIF (L-ZIF) named TZZ, which can emit ECL signals at negative potential. Moreover, magnetite microspheres were used to construct a sandwich-type biosensor to obtain higher sensitivity and reduce background signals. In addition, the biosensor manufactured directly in solution have a wider linear range than constructed on electrode because it has more available space than the electrode surface. Due to the above advantages, the prepared ECL biosensor exhibited high sensitivity, stability and broader linear range, even for practical analysis. Therefore, the prepared ECL biosensor will become a promising method for determination of α2,3-sialylated glycans and α2,6-sialylated glycans in clinical applications in the future. What is more, it provides a potential method for detection of other multi-targets.

研究领域: 分析化学 · 生物医学工程 · 传感技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。