文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

5 项

设置提升方向
Bi-DTPA
BIOMATERIALS · 2019 · IF 10.273

Bi-DTPA as a high-performance CT contrast agent for in vivo imaging

Weihua Liao,Peng Lei,Jinbin Pan,Cai Zhang,Xianting Sun,Xuejun Zhang,Chunshui Yu,Shao-Kai Sun

Clinically used iodinated computer tomography (CT) contrast agents suffer from low sensitivity, and the emerging lanthanide-chelates and CT imaging nanoagents raise great safety concerns. The fusion of high sensitivity and good biocompatibility is highly desired for the development of CT contrast agents. Herein, we propose a facile and green one-pot synthesis strategy for the fabrication of a small molecular CT contrast agent, Bi-diethylene triamine pentaacetate acid (DTPA) complex, for high-performance CT and spectral CT imaging. The Bi-DTPA exhibits yield of near 100%, outstanding water solubility, favorable biocompatibility, large-scale production capability, and superior X-ray attenuation ability, and is successfully applied in high-quality in vivo kidney imaging and gastrointestinal tract CT imaging and appealing spectral CT imaging. The proposed contrast agent can be rapidly excreted from body, avoiding the potential side effects caused by the long-term retention in vivo. Furthermore, our design shows great potential in developing diverse multifunctional contrast agents via chemical modification. The proposed Bi-DTPA with unique superiorities shows a bright prospect in clinic CT imaging, especially spectral CT imaging, and lays down a new way for the design of high-performance CT contrast agents with great clinical transformation potential.

研究领域: 医学影像学 · 生物医学工程 · 放射医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Regenerative Biomaterials · 2024 · IF 5.6

Non-invasive fast assessment of hepatic injury through computed tomography imaging with renal-clearable Bi-DTPA dimeglumine

Ma Li,Pan Jinbin,Shu Gang,Pan Haiyan,Li Jingang,Li Dong,Sun Shaokai

Enhanced computed tomography (CT) imaging with iodinated imaging probes is widely utilized for the diagnosis and evaluation of various liver diseases. However, these iodine-based imaging probes face intractable limitations including allergic reactions and contraindications. Herein, we propose the utilization of renal-clearable iodine-free bismuth chelate (Bi-DTPA dimeglumine) for the non-invasive fast assessment of hepatic ischemia–reperfusion injury (HIRI) via CT imaging for the first time. Bi-DTPA dimeglumine offers several advantages such as simple synthesis, no purification requirement, a yield approaching 100%, large-scale production capability (laboratory synthesis > 100 g), excellent biocompatibility and superior CT imaging performance. In a normal rat model, the administration of Bi-DTPA dimeglumine resulted in a significant 63.79% increase in liver CT value within a very short time period (30 s). Furthermore, in a HIRI rat model, Bi-DTPA dimeglumine enabled the rapid differentiation between healthy and injured areas based on the notable disparity in liver CT values as early as 15 min post-reperfusion, which showed a strong correlation with the histopathological analysis results. Additionally, Bi-DTPA dimeglumine can be almost eliminated from the body via the kidneys within 24 h. As an inherently advantageous alternative to iodinated imaging probes, Bi-DTPA dimeglumine exhibits promising prospects for application in liver disease diagnosis.

研究领域: 医学成像 · 肝病学 · 放射学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2025 · IF 8.2

Bismuth Chelate-Mediated Computed Tomography Perfusion Imaging of Acute Ischemic Stroke In Vivo

Lu Zhao,Li Ma,Xuetao Jia,Xiaoxue Wang,Wenjing Hou,Gang Shu,Bing Han,Dianxun Fu,Dong Li,Shao-Kai Sun,Jinbin Pan

Contrast-enhanced computed tomography perfusion (CTP) imaging is a critical clinical tool for evaluating cerebral blood flow after acute ischemic stroke (AIS), enabling accurate diagnosis and treatment planning. However, conventional iodine-based contrast agents may lead to allergic reactions and are contraindicated in patients with thyroid disorders. This study introduces Bi-DTPA dimeglumine, a renal-clearable and iodine-free bismuth chelate, for AIS perfusion assessment via CTP imaging. Bi-DTPA dimeglumine is synthesized through a simple and scalable process with nearly 100% yield (laboratory synthesis >100 g) and demonstrates excellent biocompatibility and efficient renal clearance. In a middle cerebral artery occlusion (MCAO) rat model, Bi-DTPA dimeglumine-enhanced CTP imaging accurately visualized vascular perfusion deficits, showing reduced cerebral blood volume (CBV) and cerebral blood flow (CBF), alongside prolonged time-to-maximum (Tmax) and mean transit time (MTT). Compared to iohexol, Bi-DTPA dimeglumine provided superior vascular contrast in computed tomography angiography (CTA), with contrast-to-noise ratio (CNR) improvements of 129.8 and 93.5% in normal and MCAO rats, respectively. Notably, CTP imaging revealed distinct reperfusion dynamics in ischemic regions postrecanalization. This iodine-free imaging agent marks a significant advancement in precise AIS diagnosis and post-treatment evaluation, addressing key limitations of existing contrast agents while enhancing diagnostic accuracy and safety.

研究领域: 医学影像学 · 神经科学 · 药理学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOMATERIALS · 2024 · IF 12.8

Real-time detection of gastrointestinal leaks via bismuth chelate-enhanced X-ray gastroenterography

Jinbin Pan,Jiaojiao Wang,Yujie Zhao,Bing Han,Gang Shu,Min Ma,Xu Wang,Xi Wei,Wenjing Hou,Shao-Kai Sun

Anastomotic leaks are among the most dreaded complications following gastrointestinal (GI) surgery, and contrast-enhanced X-ray gastroenterography is considered the preferred initial diagnostic method for GI leaks. However, from fundamental research to clinical practice, the only oral iodinated contrast agents currently available for GI leaks detection are facing several challenges, including low sensitivity, iodine allergy, and contraindications in patients with thyroid diseases. Herein, we propose a cinematic contrast-enhanced X-ray gastroenterography for the real-time detection of GI leaks with an iodine-free bismuth chelate (Bi-DTPA) for the first time. The Bi-DTPA, synthesized through a straightforward one-pot method, offers distinct advantages such as no need for purification, a nearly 100 % yield, large-scale production capability, and good biocompatibility. The remarkable X-ray attenuation properties of Bi-DTPA enable real-time dynamic visualization of whole GI tract under both X-ray gastroenterography and computed tomography (CT) imaging. More importantly, the leaky site and severity can be both clearly displayed during Bi-DTPA-enhanced gastroenterography in a rat model with esophageal leakage. The proposed movie-like Bi-DTPA-enhanced X-ray imaging approach presents a promising alternative to traditional GI radiography based on iodinated molecules. It demonstrates significant potential in addressing concerns related to iodine-associated adverse effects and offers an alternative method for visually detecting gastrointestinal leaks.

CAS / MDL: 67-43-6 1304-76-3
研究领域: 医学影像学 · 胃肠病学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Advanced Healthcare Materials · 2024 · IF 10

Bismuth Chelate-Mediated Digital Subtraction Angiography

Jiaojiao Wang,Dianxun Fu,Cong Tang,Gang Shu,Xuejun Zhang,Xuening Zhang,Jinbin Pan,Shao-Kai Sun

Digital subtraction angiography (DSA) is considered the “gold standard” for the diagnosis of vascular diseases. However, the contrast agents used in DSA are limited to iodine-based small molecules, which are unsuitable for patients with contraindications. Here, we propose iodine-free DSA utilizing a bismuth chelate, Bi-DTPA Dimeglumine, for vascular visualization for the first time. Bi-DTPA Dimeglumine possesses a simple synthesis process without the need for purification, large-scale production ability (over 200 g in the lab), superior X-ray imaging capability, renal clearance capacity, and good biocompatibility. Bi-DTPA-enhanced DSA can clearly display the arteries of the rabbit's head and lower limbs, with a minimum vascular resolution of 0.5 mm. The displayed integrity of terminal vessels by Bi-DTPA-enhanced DSA is superior to that of iopromide-enhanced DSA. In a rabbit model of thrombotic disease, Bi-DTPA Dimeglumine-enhanced DSA enables the detection of embolism and subsequent reevaluation of vascular conditions after recanalization therapy. Our proposed iodine-free DSA provides a promising and universal approach for diagnosing vascular diseases. This article is protected by copyright. All rights reserved

研究领域: 医学影像 · 放射学 · 血管医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。