文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
CBS酶
MICROCHEMICAL JOURNAL · 2025 · IF 5.1

An electrochemical sensor based on immobilized cystathionine β-synthase (CBS) enzymes and Pd@CuO modified covalent organic framework for specific detection of homocysteine

Xiuzhen Li,Yuanting Ni,Chenxi Liu,Shaohua Xu,Wei Shu,Hong Liang,Ming Chen

Background Homocysteine (Hcy) has been recognized as an independent risk factor for the development of cardiovascular disease. Many electrochemical detection methods have been developed for analyzing Hcy, however, the specificity of these methods is based on the interaction between the sulfhydryl groups in Hcy and the metallic materials, and thus the specificity of such detection is not satisfactory. Results In this study, an electrochemical sensor based on COFs and Pd@CuO was developed for the specific detection of Hcy. Firstly, COFs material was used as an immobilized carrier for cystathionine β-synthase (CBS), and the immobilized CBS as a recognition unit was able to catalyze the production of H 2 S from the substrates (Hcy and Cys) in a specific manner. Secondly, the Pd@CuO composite material has excellent conductivity and can catalyze H 2 S as a source of electrochemical signal generation. The electrochemical sensor constructed based on the above principles has a good electrochemical response to Hcy within the range of 5 μM to 100 μM, and the limit of detection can reach 0.11 μM (S/N = 3). In addition, the constructed sensor has good reproducibility, stability and specificity, and has good recoveries in the detection of real plasma samples, which provides a potential application for the diagnosis of homocysteinemia. Significance and Novelty The electrochemical sensor significantly increases the specificity of detection by utilizing immobilized Hcy specific catalytic enzymes CBS. In addition, Pd modified CuO@COFs electrode greatly increases the conductivity of the electrode, thereby increasing the sensitivity of detection. These characteristics make the electrochemical sensor have good application prospects for detecting the Hcy in clinic in the future.

研究领域: 生物医学工程 · 分析化学 · 临床诊断
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。