文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
CK-MB检测
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS · 2025 · IF 5.4

Vinyl sulfonamide/PEG co-immobilized on the surface of magnetic beads for the chemiluminescent immunoassay

Shihong Zhu,Daohang Du,Shuli Yu,Ting Tao,Xianfeng Chu,Yunhua Jiang,Jia Yang,Jiefu Li,Zhifei Wang

Chemiluminescent immunoassays utilizing magnetic nanoparticles exhibit critical importance in in vitro diagnostics, attributed to their remarkable superparamagnetic properties, high specificity, and uniform monodispersity. Current surface functionalization strategies for antibody conjugation predominantly rely on carboxyl or amino groups, requiring pre-activation steps for both amino- and carboxyl-modified nanoparticles prior to antibody labeling. However, the complex activation protocols and persistent challenges in developing efficient chemiluminescent detection methods highlight significant technical obstacles. To address these limitations, we developed vinyl sulfone-functionalized magnetic beads (VSF-GMP), enabling rapid antibody conjugation via specific reactions between vinyl sulfone groups and lysine residues exposed on the surface of creatine kinase MB isoenzyme antibodies (CK-MB). This approach facilitates highly efficient chemiluminescent immunoassays. The engineered VSF-GMP magnetic beads demonstrated molecular weight-dependent adsorption profiles, achieving maximal binding capacity (86.32 μg/mg) for mouse IgG (150 kDa) compared to β-lactoglobulin (18.2 kDa) and bovine serum albumin (66.4 kDa). Moreover, compared with the protein coupling method using EDC/NHS-activated carboxylated magnetic beads, our VSF-GMP beads exhibited superior coupling efficiency. Additionally, bis-functionalized poly(ethylene glycol) (NH 2 -PEG-NH 2 ) was employed as a blocking agent to optimize the reactivity and stability of antibody conjugation, reducing non-specific protein labeling on the magnetic beads by 97.8 %. The analytical performance of the proposed chemiluminescent immunoassay (CLIA) was rigorously evaluated. Finally, the practical utility of VSF-GMP magnetic beads for CK-MB determination in plasma samples was investigated. These engineered magnetic beads showcase exceptional analytical sensitivity, specificity, and operational simplicity, establishing a robust platform for advanced chemiluminescent diagnostics with enhanced throughput capabilities.

研究领域: 生物医学工程 · 分析化学 · 免疫学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。