文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
CaO2 纳米粒子
ACS Applied Materials & Interfaces · 2021 · IF 9.229

Ultrasound-Propelled Janus Rod-Shaped Micromotors for Site-Specific Sonodynamic Thrombolysis

Wenxiong Cao,Yuan Liu,Pan Ran,Jie He,Shuang Xie,Jie Weng,Xiaohong Li

Antithrombosis therapy is confronted with short half-lives of thrombolytic agents, limited therapeutic effects, and bleeding complications. Drug delivery systems of thrombolytic agents face challenges in effective penetration into thrombi, which are characterized by well-organized fibrin filled with abundant activated platelets. Herein, Janus rod (JR)-shaped micromotors are constructed by side-by-side electrospinning and cryosection, possessing advantages in controlling the Janus structure and aspect ratio of microrods. Silicon phthalocyanine (Pc) and CaO2 nanoparticles (NPs) are loaded into the separate sides of JRs, and Arg-Gly-Asp (RGD) peptides are grafted on the surface to obtain Pc/Ca@r-JRs for the sonodynamic therapy (SDT) of thrombosis without using any thrombolytic agents. Decomposition of CaO2 NPs ejects O2 bubbles from one side of JRs, and ultrasonication of O2 bubbles produces the cavitation effect, both generating mechanical force to drive the thrombus penetration. The integration of ultrasonication-propelled motion and RGD mediation effectively increases the targeting capabilities of r-JRs to activated platelets. In addition to mechanical thrombolysis, ultrasonication of the released Pc produces 1O2 to destruct fibrin networks of clots. In vitro thrombolysis of whole blood clots shows that ultrasonication of Pc/Ca@r-JRs has a significantly higher thrombolysis rate (73.6%) than those without propelled motion or RGD-mediated clot targeting. In a lower limb thrombosis model, intravenous administration of Pc/Ca@r-JRs indicates 3.4-fold higher accumulations at the clot site than those of JRs, and ultrasonication-propelled motion further increases thrombus retention 2.1 times. Treatment with Pc/Ca@r-JRs and ultrasonication fully removes thrombi and significantly prolongs tail bleeding time. Thus, this study has achieved precise and prompt thrombolysis through selective targeting to clots, efficient penetration into dense networks of thrombi, and SDT-executed thrombolysis.

研究领域: 生物医学工程 · 治疗学 · 纳米技术 · 药学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。