JOURNAL OF CHROMATOGRAPHY A
·
2013
·
IF 4.612
Hong-Fei Tong,Dong-Qiang Lin,Dong Gao,Xiao-Ming Yuan,Shan-Jing Yao
Hydrophobic charge-induction chromatography (HCIC) is a novel downstream bioprocessing technology for antibody purification and it has several advantages over traditional purification processes. However, its separation selectivity still needs to be improved. In this work, sodium caprylate (NaCA) was used as the selective modifier to improve IgG purification from serum albumin containing feedstock with a typical HCIC resin, MEP HyperCel. The effects of NaCA on the adsorption equilibrium of bovine serum immunoglobulin G (IgG) and bovine serum albumin (BSA), as well as the dynamic binding and displacement behaviors were investigated. The binding and elution behaviors of these two proteins in the column were studied. It was found that adding 50–75 mM NaCA in the liquid phase could effectively reduce the adsorption of BSA on the MEP resin, but the same treatment has little influence on the adsorption of IgG. Moreover, the mechanism of the competitive binding between caprylate and MEP ligands on the surface of BSA is discussed. It was found that by controlling NaCA addition in the loading or washing buffer, the process efficiency of IgG purification from BSA containing feedstock can be improved, and the purity of IgG could reach to over 98%. The results indicated that caprylate could be a promising albumin-selective modifier to improve the separation efficiency of antibodies with the HCIC process.
研究领域:
生物技术
·
蛋白质纯化
·
抗体工程
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF MOLECULAR LIQUIDS
·
2020
·
IF 5.065
Xiaojie Wang,Weibiao Du,Xiaopo Wang
In this work, the high-pressure liquid viscosities of ethyl caprylate and ethyl caprate were measured at the temperatures from 303 K to 362 K and pressures up to 30 MPa. The measurements were carried out based the falling-cylinder viscosity measurement system which was established in our laboratory. The combined expanded relative uncertainty of the present measurement was <0.03 with a confidence level of 0.95. The high-pressure viscosity values were correlated with Andrade-Tait equation. The average relative deviation between experimental data and calculated results from Andrade-Tait equation for ethyl caprylate and ethyl caprate was 0.38% and 0.73%, respectively. The maximum relative deviation was 1.32% and 1.96%, respectively.
研究领域:
化学工程
·
物理化学
✓ 已验证
产品关联
DOI
高影响因子
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
·
2023
·Vol. 415
·期 12
·2163-2172
·
IF 4.3
Zhang Haotian,Wang Xiaohong,Xu Zuhui,Ma Jimei,Li Zi-Long,Cheng Wan-Min,Jiang Hong
Salmonella enteritidis is one of the most common foodborne pathogens. Many methods have been developed to detect Salmonella , but most of them are expensive, time-consuming, and complex in experimental procedures. Developing a rapid, specific, cost-effective, and sensitive detection method is still demanded. In this work, a practical detection method is presented using salicylaldazine caprylate as the fluorescent probe, which could be hydrolyzed by caprylate esterase liberated from Salmonella lysed by phage, to form strong fluorescent salicylaldazine. The Salmonella could be detected accurately with a low limit of detection of 6 CFU/mL and a broad concentration range of 10–10 6 CFU/mL. Moreover, this method was successfully used for the rapid detection of Salmonella in milk within 2 h through pre-enrichment by ampicillin-conjugated magnetic beads. The novel combination of fluorescent turn-on probe salicylaldazine caprylate and phage ensures this method has excellent sensitivity and selectivity. Graphical Abstract
研究领域:
微生物学
·
食品安全
·
生物化学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF CHEMICAL THERMODYNAMICS
·
2019
·
IF 2.29
Xiaojie Wang,Shanshan Zhu,Xiaopo Wang
The experimental measurements for liquid viscosities of four fatty acid methyl esters, including methyl hexanoate, methyl heptanoate, methyl caprylate, and methyl nonanoate, were carried out with a falling-cylinder viscometer. For the present measurement, the temperature ranges were from 292 K to 362 K and the pressure was reached to 30 MPa. The combined expanded relative uncertainty of the viscosity measurements was within 0.03 with 0.95 confidence level. The viscosity data for each studied esters were correlated by Andrade-Tait equation, and the average absolute relative deviation between the experimental data and calculated values is 0.31%, 0.44%, 0.38%, and 0.25% for methyl hexanoate, methyl heptanoate, methyl caprylate, and methyl nonanoate, respectively. The maximum absolute relative deviation is 1.09%, 1.28%, 1.28%, and 0.75%.
研究领域:
化学工程
·
物理化学
✓ 已验证
产品关联
DOI
高影响因子
JOURNAL OF CHEMICAL AND ENGINEERING DATA
·
2019
·
IF 2.298
Junshuai Chen,Ying Zhang,Taotao Zhan,Qi Zhou,Tian Lan,Maogang He
Methyl caprylate is expected to be one of the main components of biodiesel due to its high cetane number and good oxidation stability. Details of the experimental speeds of sound in methyl caprylate are very scarce, especially in high-temperature regions. Therefore, the speed of sound in liquid methyl caprylate was measured by the Brillouin light scattering method in the temperature range of 298.22–608.38 K and at pressures of up to 10 MPa. The relative expanded uncertainty of the speed of sound is estimated to be less than 1.32% (coverage factor k = 2). The variation of the speed of sound with the temperature and pressure was analyzed. Besides, the correlation for the speed of sound as a function of temperature and pressure is presented based on the experimental data. The absolute average of relative deviation between the experimental data and the calculated results is 0.29%.
研究领域:
物理化学
·
能源科学
✓ 已验证
产品关联
DOI
高影响因子
MOLECULES
·
2020
·Vol. 25
·期 8
·1957
·
IF 3.267
Ying Li,Chunyan Zhu
Microspheres containing absorption enhancer (sodiumN-[8-(2-hydroxybenzoyl)amino]caprylate, SNAC) were developed to enhance the oral bioavailability of berberine hydrochloride (BER) with poor intestinal membrane permeability. Microspheres were prepared and characterized by particle size measurements, scanning electron microscopy, differential scanning calorimetry, BER payload and release, Caco-2 cell monolayer transport, and rat pharmacokinetics. The microspheres were spherical and had uniform size, high encapsulation efficiency and high loading capacity. In vitro release studies showed that BER-loaded microspheres had good sustained release characteristics. The Caco-2 cell monolayer transport study proved that SNAC could significantly enhance permeability of BER 2–3-fold. Pharmacokinetic studies demonstrated a 9.87-fold increase in area under the curve (AUC) of BER mixed with SNAC and a 14.14-fold increase in AUC of microspheres compared with BER alone. These findings indicate that SNAC is a promising absorption enhancer for oral delivery of BER in the form of both solution and microspheres.Keywords:sodiumN-[8-(2-hydroxybenzoyl)amino]caprylate;permeation enhancement;berberine hydrochloride;microspheres;oral bioavailability
研究领域:
药剂学
·
药物代谢动力学
✓ 已验证
产品关联
DOI
PubMed
高影响因子