The inappropriate use of H2 receptor antagonists (H2RAs) in functional foods (FFs) and food-medicine homology materials (FMHs) designed to enhance gastrointestinal function (IGF) presents health risks due to potential adverse effects. In this study, an analytical method that integrates Captiva EMR-Lipid (CEL) solid-phase extraction (SPE) with liquid chromatography tandem mass spectrometry (LC-MS/MS) has been developed for the detection of H2RAs (nizatidine, famotidine, cimetidine, ranitidine, and lafutidine) in these products. Through the optimization of CEL-SPE parameters, such as using 200 mg of sorbent and eluting with ACN/water (80/20, v/v), the recovery rates of H2RAs in IGF-FF and IGF-FMH ranged from 87.4 % to 94.6 % and 90.2 % to 97.1 %, respectively. The assessment of matrix effects revealed that the five H2RAs exhibit matrix suppression, necessitating the construction of matrix-matched standard curves with correlation coefficients (r 2 ) exceeding 0.9991. The detection limits ranged from 0.4 to 0.8 μg·kg −1 and the quantification limits ranged from 1.3 to 2.7 μg·kg −1 , with recovery rates spanning from 85.4 % to 97.1 % and relative standard deviations ≤ 15 %. The successful development of this technique not only helps safeguard consumer health but also provides scientific basis and technical support for market supervision, thereby preventing and addressing food safety risks.
Fluorescent brighteners (FBs) are a class of chemicals extensively used in industrial and consumer products. Their environmental occurrences and potential health risks have raised significant concerns. However, the lack of analytical methods for FBs in human samples has hindered the accurate assessment of internal exposure levels. Addressing this gap, this study developed and validated a novel method for the simultaneous determination of 13 FBs at trace levels in human plasma using solid-phase extraction combined with HPLC-MS/MS. The method employed EMR-Lipid SPE columns, which can selectively adsorb phospholipids for plasma sample pre-treatment. Detection was achieved through positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) modes. The results showed that all 13 FBs exhibited good linearity within their respective ranges, with correlation coefficients (R2) greater than 0.992. The method quantitation limits (MQLs) of the FBs ranged from 0.012 to 0.348 ng/mL, and the spiked recovery rates ranged from 61% to 98%. The method was successfully applied to analyze 10 adult plasma samples, detecting 10 FBs with total concentrations ranging from 0.221 to 0.684 ng/mL. This study provides a reliable analytical method for determining FBs in human plasma, providing a basis for further research on human internal exposure to FBs and associated health risk assessments.