文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
Cu2 触发
SENSORS AND ACTUATORS B-CHEMICAL · 2024 · IF 8

Cu2+-triggered wavelength-tunable real-time in situ fluorogenic immunoassay for detection of cTnI in human serum

Hong Yang,Shanshan Zhu,Lihua Pang,Yifei Ma,Xiaoxue Liu,Jinhua Liu

ABSTRACT Using a single emission-wavelength to accurately/sensitively quantify disease markers in complex environments still faces enormous challenges. In this study, we construct a Cu 2+ -triggered wavelength-tunable fluorescent immunoassay for real-time detection of cTnI in human serum. The developed platform is based on an “on-off-on” strategy, which involves the rapid in-situ fluorogenic reaction of dopamine (DA) and phenol analogue by Cu 2+ , strong coupling between PPi and Cu 2+ as well as the specific hydrolysis of PPi into orthophosphate by alkaline phosphatase. By using cTnI as a model antigen, the assay shows good linearity relationships between the fluorescence response and cTnI concentration. Furthermore, we used different phenol analogues (1,3-dihydroxynaphthalene, 8-hydroxyjulolidine, 1,5-dihydroxynaphthalene) as fluorescence reaction substrates to achieve multi-channel (blue, green and yellow) real-time monitoring of cTnI with detection limits of 0.17   ng/mL, 0.17   ng/mL and 0.33   ng/mL, respectively. We successfully applied the wavelength-tunable ELISA to detect cTnI levels in real human serum, and the results were compared with a commercial ELISA with satisfactory outcomes. Therefore, our proposed platform demonstrates great potential in the early diagnosis of acute myocardial infarction.

研究领域: 分析化学 · 生物化学 · 医学诊断 · 心脏病学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2021 · IF 7.46

In situ Cu2+-triggered wavelength-tunable fluorescent sensor for highly sensitive sensing inorganic pyrophosphatase activity and its logic gate application

Can Chen,Guotong Ruan,Yujie Sun,Lili Wang,Chengwu Zhang,Jinhua Liu

As inorganic pyrophosphatase (PPase) gets involved in the regulation of various pathophysiological procedures, rapid and effective detection of its activity is of great value for monitoring and managing PPase-related diseases. Herein, an in situ Cu 2+ -triggered wavelength-tunable fluorescent sensor for high sensitivity monitoring of PPase activity is constructed. The proposed sensor is based on the principle of Cu 2+ -triggered polymerization of dopamine (DA) and m-phenylenediamine (MPD), the stronger coupling effect of pyrophosphate ion (PPi) and Cu 2+ , and the effective hydrolysis of PPase to PPi. With the change of substituents of MPD, the wavelength of fluorescence polymer nanoparticles (FPNPs) exhibits tunable capacity from 535 nm to 565 nm. Compared with the traditional detection method, as developed sensor shows high sensitivity to PPase with a low detection limit of 0.333 mU/mL in green channel and 0.033 mU/mL in orange channel. Additionally, the sensor realizes PPase sensing in the diluted human serum with excellent recovery in both green and orange models. Furthermore, this sensor is also applicable for inhibition assay of PPase (NaF: IC 50 of 134.7 μM) and logic gates construction. Summarily, as prepared sensor provides one better way for monitoring PPase in diagnostic as well as drug screening.

研究领域: 生物化学 · 分析化学 · 分子生物学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。