文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
DBD-M-Pro手性探针
JOURNAL OF CHROMATOGRAPHY A · 2021 · IF 4.759

Highly sensitive novel fluorescent chiral probe possessing (S)-2-methylproline structures for the determination of chiral amino compounds by ultra-performance liquid chromatography with fluorescence: An application in the saliva of healthy volunteer

Xi-Ling Li,Yu Han,Yuan Huang,Xiaoqi Sun,Shuyun Xiao,Jun Zhe Min

We developed a novel fluorescent chiral probe, DBD-trans-2-methyl-L-proline (DBD-M-Pro), which can be used to target recognition of amino functional groups using chiral resolution. To investigate the chiral resolution efficiency, 20 chiral amino enantiomers (19 DL-amino acids and phenylethylamine) were labeled using ultra-performance liquid chromatography (UPLC) with a fluorescence (FL) system. Diastereomers were formed by the reactions of DBD-M-Pro with enantiomers of amino functional groups at 60 °C for 60 min and detected on a BEH C18 column (100 × 2.1 mm, 1.7 μm). Gradient elution of 10 mM ammonium acetate with 0.05% formic acid (FA) aqueous solution and 0.1% FA acetonitrile or 0.1% FA methanol solution was performed at an excitation wavelength (Ex) 460 nm and emission wavelength (Em) 550 nm. Each resulting derivative of D- and L- type was effectively separated. The results showed that the resolution (Rs) of 17 amino acids and phenylethylamine (PEA) in the range of 1.59–24.11, except for histidine (His) (Rs = 1.32) and serine (Ser) (Rs = 1.47), achieved completely separation. The DBD-M-Pro chiral probe has a robust chiral selectivity for D-amino acids. Furthermore, a new method for the simultaneous determination of six DL-amino acids (Pro, Val, Trp, Phe, Leu, Lys) in human saliva was developed. The proposed method showed resolution values of 1.78–16.38, and an excellent linear relationship was obtained in the range of 2.5–500 pmol ( R 2  ≥ 0.9990). The limit of detection (S/ N  = 3) ranged from 0.5 to 3.75 pmol. The intra-day and inter-day coefficient of variation (CV) were within the range of 1.75–11.73%. The average addition recoveries in saliva ranged from 95.99 to 106.97%. The methodology was used to determine the content of DL-amino acids and the D/L-amino acid ratio in the saliva of 40 healthy volunteers (15 males and 25 females), as well as evaluating the differences between men and women. Our study suggests that the DBD-M-Pro chiral probe could be an effective tool for screening potential D-amino acid biomarkers in disease.

研究领域: 分析化学 · 生物化学 · 医学诊断
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。