文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
DMETEG
ENERGY · 2021 · IF 7.147

Vapor-liquid equilibrium measurements and assessments of Low-GWP absorption working pairs (R32+DMETEG, R152a+DMETEG, and R161+DMETEG) for absorption refrigeration systems

Xiao Zhang,Liang Cai,Tao Chen,Jingyi Qiao,Xiaosong Zhang

This research aims to develop novel binary working pairs using low-GWP refrigerants (R32, R152a, or R161) and one chemical absorbent (DMETEG) for absorption refrigeration systems . The solubility data were determined from 293.15 to 343.15 K using a static method and were correlated with the five-parameter non-random two-liquid (NRTL) activity coefficient model with an average relative absolute error of <2.4%. All three binary mixtures exhibited negative deviations from Raoult’s law. DMETEG was further assessed with other organic solvents that were previously measured to verify its highest affinity with HFCs. Based on the obtained VLE data, the thermodynamic performances in both the single-stage absorption refrigeration system (ARS) and the absorption-compression hybrid refrigeration system (ACHRS) were assessed. R161 yielded the highest cooling COP of 0.519–0.555 when the generation temperature was above 135 °C, followed by the R152a at 0.231–0.518 when below 135 °C. Different from the trends of COP variations, R152a had the highest ECOP of 0.091–0.158 when the generation temperature was below 135 °C while R161 showed the highest ECOP of 0.116–0.137 over 135 °C. ACHRS can effectively enhance the cooling performances of ARS via compression and its compression ratios got optimized. Overall, the R161 + DMETEG showed the best potential as the working pair.

CAS / MDL: 68-12-2
研究领域: 化学工程 · 制冷技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
APPLIED THERMAL ENGINEERING · 2023 · IF 6.4

Experimental studies on absorption-compression hybrid refrigeration system using 1,1,1,2-tetrafluoroethane/tetraethylene glycol dimethyl ether as working pair

Xiao Zhang,Liang Cai,Yu Liang,Zhenxi Ma,Xiaosong Zhang

The feasibility of combining novel halogenated hydrocarbon-based working pairs with low-pressure compression-assisted absorption refrigeration system (LCARS) was proved for the first time from the experimental perspective. An experimental prototype of the absorption-compression hybrid refrigeration system with a 1 kW cooling capacity was designed and tested to explore actual performances of selected R134a-DMETEG and performance improvements from compression in LCARS. At an evaporation temperature of approximately 5 °C, as the hot water inlet temperature and the solution flow rate change from 75 to 95 °C and 1.2–2.7 L/min, respectively, the coefficient of performance (COP) in the single-stage absorption refrigeration system (SSARS) varies from 0.211 to 0.412. At an increased evaporation temperature of approximately 10 °C, as the hot water inlet temperature and flow rate increase from 70 to 80 °C and 1.18–2.89 L/min, respectively, the COP in the SSARS varies from 0.238 to 0.552, while the COP in LCARS is improved and varies from 0.470 to 0.617. The LCARS increases the COP by a maximum of 91.04 % and can utilize a lower-grade heat source more efficiently due to its higher optimal COP at reduced hot water inlet temperatures. This study provided one feasible technical approach of combined use of R134a-DMETEG and LCARS to make up for the application limitations of traditional working pairs, contributing to application promotions of absorption systems, especially for the occasions with high requirement on safety and lightweight.

CAS / MDL: 143-24-8
研究领域: 制冷工程 · 能源与动力工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。