文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
DNA固定化
BIOSENSORS & BIOELECTRONICS · 2015 · IF 6.409

β-Cyclodextrin functionalized graphene as a highly conductive and multi-site platform for DNA immobilization and ultrasensitive sensing detection

Yizhen Yang,Feng Gao,Xili Cai,Xiaoning Yuan,Suyu He,Fei Gao,Hongxu Guo,Qingxiang Wang

A versatile nanocomposite containing β-cyclodextrin and graphene (CD–GR) was prepared through a simple chemical reduction method. The characterization experiments show that the nanocomposite remains the flake-like morphology of GR, but its solubility and stability in aqueous solution are greatly improved. Then the nanocomposite was modified at glassy carbon electrode (GCE) surface, and was used as a functional matrix for the covalent immobilization of probe DNA using 2,4,6-trichloro-1,3,5-triazine (TCT) as the crosslinker . Due to the synergetic effect of large surface area of GR and rich hydroxyl of CD, the probe density for the developed biosensor was determined to as high as 3.82×10 13   molecules   cm − 2 . Meanwhile, the biosensor shows high hybridization efficiency and hybridization kinetic. When the biosensor was applied for the impedance-based hybridization test, a wide linear range from 1.0×10 −16 to 1.0×10 −12   M and an ultralow detection limit of 3.4×10 −17   M were achieved. The biosensor also displays excellent stability, selectivity , and reproducibility.

CAS / MDL: 77-86-1
研究领域: 纳米技术 · 生物传感器 · 分析化学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
BIOPOLYMERS · 2013 ·Vol. 101 ·期 5 ·496-503 · IF 2.879

DNA detection and cell adhesion on plasma-polymerized pyrrole

Zhihong Zhang,Shunli Liu,Yu Shi,Jun Dou,Shaoming Fang

This study investigates the application of Plasma-polymerized pyrrole (ppPY) as bioactive platform for DNA immobilization and cell adhesion based on the fundamental properties of ppPY, such as chemical structure, electrochemical property, and protein adsorption. Variations in electrochemical properties of the ppPY film deposited under different plasma conditions before and after DNA immobilization were measured using electrochemical impedance spectroscopy (EIS). The equilibrium concentration of the probe DNA immobilized on the ppPY surface was deduced by detecting the variations in the surface charge transfer resistance ( R ct ) of the ppPY films after DNA immobilization with different concentrations. In addition, the detection limit of the target DNA hybridization with probe DNA, the association constant, K a , and the dissociation constant were deduced from Langmuir isotherm equations simulated using the experimental data collected by EIS. Moreover, inverted microscope was used to observe the cell adhesions onto the surface of the ppPY films prepared under different plasma conditions. Different adhesive behaviors of cells were observed, demonstrating that ppPY films could be an alternative biomaterial used as the sensitive layer for DNA sensor or cell adhesion. © 2013 Wiley Periodicals, Inc. Biopolymers 101: 496–503, 2014.

CAS / MDL: 109-97-7
研究领域: 生物材料 · 电化学 · 分子生物学 · 细胞粘附
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYST · 2011 ·Vol. 137 ·期 2 ·414-419 · IF 3.913

Electrochemical detection of dihydromyricetin using a DNA immobilized ethylenediamine/polyglutamic modified electrode

Lina Zou,Ying Xu,Peili Luo,Shusheng Zhang,Baoxian Ye

A novel voltammetric sensor, based on DNA immobilized on the surface of an ethylenediamine/polyglutamic (En/PGA) modified glassy carbon electrode (GCE), was constructed and used for determination of dihydromyricetin (DMY). The electrochemical behaviour of DMY at this sensor was investigated in pH 3.6 NaAc-HAc buffer solutions by cyclic voltammetry (CV) and differential pulse anodic voltammetry (DPV). The oxidation of DMY is an adsorption-controlled irreversible process. The oxidation mechanism was proposed and discussed. It was found that the modified electrode exhibited a linear voltammetric response for DMY in the range of 4.0 × 10−8 mol L−1 to 2 × 10−6 mol L−1, with a detection limit of 2 × 10−8 mol L−1. The method was also applied successfully to detect DMY in an ampelopsis sample with satisfactory results.

CAS / MDL: 31137-74-3 132286-79-4
研究领域: 分析化学 · 电化学 · 药物分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。