MICROCHEMICAL JOURNAL
·
2024
·
IF 4.9
Wenrong Cai,Yanjing Shi,Datong Wu,Junyao Li,Laidi Xu,Yong Kong
This work proposes a novel dual-signal electrochemiluminescence ( ECL) immunosensor based on energy resonance transfer (RET) for the detection of β2-Microglobulin (β2-MG). Introducing carbon vacancy into g-C 3 N 4 (V C -g-C 3 N 4 ) can lead to the narrowing of the band gap and the reduction of LUMO, thereby significantly enhancing the ECL efficiency of the material. Meanwhile, Zr-MOF can effectively load Ru(bpy) 3 2+ (Ru-Zr-MOF), enabling its stable existence on the electrode. The ECL emission spectrum of V C -g-C 3 N 4 overlaps well with the fluorescence excitation spectrum of Ru-Zr-MOF, indicating an effective ECL-RET effect between them. As the concentration of β2-MG increases, the intensity of anodic ECL signal gradually increases, while the intensity of cathodic ECL signal gradually decreases. The difference between the cathodic and anodic ECL signals has a good linear relationship within the concentration range from 0.2 pg/mL to 200 ng/mL, with a detection limit of 27.73 fg/mL. The constructed immunosensor can be used for practical analysis in human serum. The proposed sensor has great potential in clinical detection of β2-MG, providing new insights for biomolecular detection and disease diagnosis.
研究领域:
生物化学
·
分析化学
·
生物医学工程
·
临床诊断
✓ 已验证
产品关联
DOI
高影响因子
TALANTA
·
2020
·
IF 5.339
Yixin Liu,Binxiao Li,Yuanyuan Yao,Beibei Yang,Tongtong Tian,Yan Miao,Baohong Liu
An electrochemiluminescence (ECL) resonance energy transfer system is constructed for 17β-estradiol (E2) detection using α [email protected] nanospheres as the ECL-active substrates and Ag NCs as an efficient quencher. CdS QDs loaded onto three-dimensional (3D) urchin-like α-FeOOH nanospheres (α [email protected] nanospheres) exhibited excellent ECL responses, which is attributed to dual-amplification of α-FeOOH frameworks. The 3D hierarchical structure of the α-FeOOH nanospheres provided abundant sites for loading ECL-active species, thus significantly improving the ECL performance of substrates; While Fe 3+ presented on surface of α-FeOOH nanospheres could be reduced to Fe 2+ in negative potentials, after which might activate persulfate in a Fenton-like process, resulting in more sulfate free radicals for more effective ECL responses via electron transfer reactions. Additionally, Ag nanoclusters (Ag NCs) stabilized by single stranded oligonucleotide were introduced as quenching probes for CdS QDs owing to the well-matched donor-acceptor spectrum for efficient energy transfer, which makes them appropriate for detection of E2. The proposed strategy displayed a desirable dynamic range from 0.01 to 10 pg mL −1 with a limit of detection of 0.003 pg mL −1 . The proposed strategy based on the ECL-RET strategy offered an ideal way for E2 detection, and also revealed an alternative platform for detection of other small molecules.
研究领域:
分析化学
·
生物化学
·
纳米技术
·
环境科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
MICROCHIMICA ACTA
·
2022
·Vol. 189
·期 11
·1-15
·
IF 6.408
Qin Dongmiao,Meng Shuo,Wu Yusheng,Luo Zhi,Deng Biyang
An efficient electrochemiluminescence resonance energy transfer (ECL-RET) method is proposed which combines the luminescent materials of tris(4,4′-dicarboxylicacid-2,2′-bipyridyl) ruthenium(II) (energy donor) and tin dioxide and tin disulfide quantum dots (SnO 2 /SnS 2 QDs) (energy acceptor) into the isoreticular metal − organic framework-3 (IRMOF-3) material to form a composite. In this mode, the distance between the energy donor and the acceptor was greatly shortened, reducing the energy loss, and thereby effectively improving RET efficiency and further significantly improving the ECL signal. The obtained composite (SnO 2 /SnS 2 QDs-Ru@IRMOF-3) was combined with sandwich immunoreaction to construct an ECL immunosensor for the sensitive detection of procalcitonin (PCT). Under the optimized experimental conditions with a working potential of − 1.48 V (vs Ag/AgCl), the proposed PCT biosensor exhibited a linear concentration range of 1 × 10 −4 –200 ng mL −1 , with a detection limit of 0.029 pg mL −1 ( S / N = 3). The biosensor was used to detect PCT in actual samples. The biosensor has broad application prospects in biological analysis and clinical diagnosis due to its high sensitivity, good selectivity, and good stability. Graphical abstract
研究领域:
分析化学
·
生物传感器
·
临床诊断
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ANALYTICAL CHEMISTRY
·
2023
·
IF 7.4
Fan Yang,JinBo Gong,Ming Li,Xiangyang Jiang,Jiawen Zhang,Meiyan Liao,Hanfei Zhang,Pier-Luc Tremblay,Tian Zhang
PCR-based techniques routinely employed for the detection of mutated linear DNA molecules, including circulating tumor DNA (ctDNA), require large nucleotide sections on both sides of the mutation for primer annealing. This means that DNA fragments with a mutation positioned closer to the extremities are unlikely to be detected. Thus, sensors capable of recognizing linear DNA with characteristic mutations closer to the ends would be advantageous over the state-of-the-art approaches. Here, an electrochemiluminescence-resonance energy transfer (ECL-RET) biosensor comprising capped CdS quantum dots and hairpin DNA probes labeled with Au nanoparticles was developed for the detection of epidermal growth factor receptor (EGFR) ctDNA carrying the critical T790M lung cancer mutation. The ECL-RET system detected different DNA molecules including single-stranded 18-nucleotides (nt) and 40-nt as well as double-stranded 100-nt with the single nucleotide polymorphism (SNP) coding for T790M located either in the middle or only 7 nt from one end. For all target DNA, the sensor’s limits of detection (LODs) were in the aM range, with excellent selectivity. It was the case of 100-nt target linear ctDNA fragments with LODs of 8.1 and 3.4 aM when the EGFR T790M SNP was either in the middle or at the end, respectively. These results show that ECL-RET systems can sense mutations in DNA fragments that would remain undetected by standard techniques.
研究领域:
生物传感器
·
纳米技术
·
癌症研究
·
分子生物学
·
分析化学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
ANALYST
·
2019
·Vol. 144
·期 22
·6554-6560
·
IF 4.019
Liping Zhu,Jing Ye,Mengxia Yan,Qiuju Zhu,Xiurong Yang
In this study, a wavelength-resolved electrochemiluminescence resonance energy transfer (ECL-RET) ratiometric immunosensor from Au nanoparticle functionalized graphite-like carbon nitride nanosheets (Au-g-C3N4) to Au nanoclusters (Au NCs) has been constructed for the first time. At a working voltage of 0 to −1.2 V, Au-g-C3N4 showed a strong cathodic ECL emission with a peak at 460 nm, which overlapped well with the absorption spectra of Au NCs thus stimulating the fluorescence emission of Au NCs at 610 nm. Moreover, within this voltage range, the Au NCs showed no ECL signal; therefore, they would not interfere with the detection of the system. We used cardiac troponin I (cTnI) as an analytical model to construct a sandwich immunosensor based on the ECL-RET ratiometric strategy. By measuring the responses of the ECL460 nm/FL610 nm ratio at different cTnI concentrations, the sensitive detection of cTnI with a wide range of 50 fg mL−1 to 50 ng mL−1 and a low detection limit of 9.73 fg mL−1 can be achieved. This work enriches the wavelength-resolved ECL-RET system and provides an innovative reference for the development of more efficient and sensitive ECL-RET ratiometry.
研究领域:
分析化学
·
生物化学
·
纳米技术
·
电化学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
TALANTA
·
2019
·
IF 4.916
Jingwen Gao,Ziyi Chen,Lebao Mao,Wei Zhang,Wei Wen,Xiuhua Zhang,Shengfu Wang
In this work, an innovative aptasensor based on electrochemiluminescence resonance energy transfer (ECL-RET) from CdTe quantum dots (QDs) to a cyanine dye (Cy5) fluorophore for the determination of Ochratoxin A (OTA) was fabricated. A strong cathodic ECL emission was obtained by the CdTe QDs modified glassy carbon electrode (GCE). After the immobilization with the capture DNA (cDNA) and the sequential hybridization with the probe DNA-modified Cy5 (pDNA, the aptamer of OTA), the ECL signal enhanced obviously through the ECL-RET. Meanwhile, the spectrum- and distance-related ECL enhancement effect was investigated. When the target OTA was in the presence, the pDNA-Cy5 molecules were released from the electrode surface owing to the specific interaction between OTA and aptamer, resulting in an evident decrease of ECL signal. Under optimal conditions, the developed aptasensor displayed the linear response toward OTA in the wide range of 0.0005–50 ng/mL with a low detection limit of 0.17 pg/mL. With the excellent selectivity , stability and repeatability, the strategy provided an efficient and universal method for the sensitive detection of target in practical application.
研究领域:
分析化学
·
生物传感器
·
毒理学
·
食品安全
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF ELECTROANALYTICAL CHEMISTRY
·
2022
·
IF 4.598
Libo Li,Bainian Chen,Xiaohong Liu,Panao Jiang,Lijun Luo,Xia Li,Tianyan You
Divalent mercury ion (Hg 2+ ) is widely distributed in the ecological environment and harmful to the human body and the environment. Herein, a highly sensitive and selective ‘on–off-on’ electrochemiluminescence (ECL) aptamer sensing method based on the dual signal amplification strategy of a self-enhanced luminophore and ECL resonance energy transfer (ECL-RET) was developed to detect Hg 2+ . In detail, the first ‘switch-on’ state was obtained by the self-enhanced luminophore of Ru(bpy) 3 2+ -doped silica nanoparticle-nitrogen-doped graphene quantum dots ( [email protected] 2 -NGQDs) modified glassy carbon electrode, which significantly amplified the ECL intensity compared with the mixture of [email protected] 2 and NGQDs . Later, the ‘switch-off’ state was induced by gold nanoparticles (AuNPs), which acted the acceptor in the ECL-RET system between AuNPs and [email protected] 2 -NGQDs due to their good spectral overlap. This combination of the self-enhanced luminophore and ECL-RET provided a novel dual signal amplification strategy, which led to a high signal-to-noise ratio and high analysis sensitivity. Finally, upon the addition of Hg 2+ , the formation of a stable T-Hg 2+ -T structure induced the release of AuNPs from the sensing interface and halted the ECL-RET process, resulting in ECL signal recovery (the second ‘switch-on’ state). For the detection of Hg 2+ , the proposed ECL sensor exhibited a wide linear range from 1 × 10 −14 to 1 × 10 −6 M and a highly sensitive detection limit of 3.0 fM. Finally, the feasibility of the developed method in water sample analysis was investigated.
研究领域:
分析化学
·
环境科学
·
材料科学
·
纳米技术
·
传感器技术
✓ 已验证
产品关联
DOI
高影响因子