文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
Eu@UiO-66-NH2-PMA
ANALYTICA CHIMICA ACTA · 2024 · IF 5.7

Dual-emissive europium doped UiO-66-based ratiometric light-up biosensor for highly sensitive detection of histidinemia biomarker

Li Li,Lin-Lin Zhang,Jin Zou,Jiamin Zou,Lu-Ying Duan,Yansha Gao,Guanwei Peng,Xigen Huang,Limin Lu

Background Lanthanide metal-organic frameworks (Ln-MOFs) are a kind of emerging crystalline porous materials with high fluorescence and easy-to-tunable properties, making them ideal for sensing applications. However, current Ln-MOFs based fluorescent probes are primarily single-emissive or fluorescence-quenched, which greatly limited the detection performances such as sensitivity, accuracy and repeatability, thereby hindering their applications in efficient target monitoring and related disease diagnosis. To address these issues, the reasonable design of Ln-MOFs equipped with dual fluorescence emissions and light-up mode is urgently needed for a high-performance biosensor . Results A dual-emissive europium doped UiO-66 (Eu@UiO-66-NH 2 -PMA)-based ratiometric fluorescent biosensing platform was constructed for highly sensitive and selective detection of the histidinemia biomarker-histidine (His). Eu@UiO-66-NH 2 -PMA (pyromellitic acid abbreviated as PMA) was synthesized utilizing a post-synthetic modification method via coordination interactions between the free –COOH of UiO-66-NH 2 -PMA and Eu 3+ , which exhibited characteristic peaks of broad ligand emission and sharp Eu 3+ emissions simultaneously. Considering that Cu 2+ had the excellent fluorescence quenching ability toward Eu 3+ and superior affinity with His, it was deliberately introduced into the Eu@UiO-66-NH 2 -PMA, acting as active sites for target His responsiveness. The Eu@UiO-66-NH 2 -PMA/Cu 2+ /His ternary competition system demonstrated a low detection limit of 74 nM, excellent selectivity and good anti-interference capability that allowed for sensitive analysis of His levels in milk and human serum samples. Significance Attributing to the superior luminescent properties, good stability and self-calibration capability of Eu@UiO-66-NH 2 -PMA, the developed ratiometric light-up sensing platform enabled sensitive, selective and credible analysis of His in complex practical samples, which might provide an available tool for food nutrition guideline and diagnostic applications of His related diseases.

研究领域: 生物化学 · 医学诊断 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。