文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

5 项

设置提升方向
Eu-DPA
ANALYTICAL AND BIOANALYTICAL CHEMISTRY · 2019 ·Vol. 411 ·期 7 ·1453-1465 · IF 3.286

Simultaneous detection of fumonisin B1 and ochratoxin A using dual-color, time-resolved luminescent nanoparticles (NaYF4: Ce, Tb and NH2-Eu/DPA@SiO2) as labels

Niazi Sobia,Khan Imran Mahmood,Yan Lv,Khan Muhammad Issa,Mohsin Ali,Duan Nuo,Wu Shijia,Wang Zhouping

A rapid and highly sensitive time-resolved fluorescence (TRF)-based aptasensor for simultaneous recognition of mycotoxins ochratoxin A (OTA) and fumonisin B 1 (FB 1 ) was developed using multi-color, Ln 3+ -doped time-resolved fluorescence nanoparticles (TRF-NPs) (NaYF 4 : Ce, Tb and NH 2 -Eu/DPA@SiO 2 NPs) coupled with complementary strand DNA (cDNA) as luminescence probe and aptamers-conjugated amine-functionalized Fe 3 O 4 magnetic nanoparticles (MNPs) act as a capture probe. Under the optimized conditions, the time-resolved fluorescence intensities at 544 and 618 nm corresponded with Tb 3+ and Eu 3+ , respectively, were used to measure FB 1 ( Y  = 19,177.1 + (− 12,054.4) x , R 2  = 0.9917) and OTA ( Y  = 4138.8 + (− 11,182.6) x , R 2  = 0.9924), respectively. The limits of detection (LODs) for FB 1 and OTA were 0.019 pg mL −1 and 0.015 pg mL −1 , respectively, which were much lower than previously described methods for simultaneous recognition of mycotoxins OTA and FB 1 while detection range varied from 0.0001–0.5 ng mL −1 . This aptasensor was effectively applied to quantity FB 1 and OTA in maize samples and results were compared with ELISA method. This is the first reported time-resolved fluorescence (TRF)-based aptasensor to detect two agriculturally important toxins in the maize. The developed aptasensor has potential to be used for detection of toxins in food safety fields. Graphical abstract

研究领域: 食品安全 · 分析化学 · 纳米技术 · 毒理学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2017 · IF 5.401

Ratiometric fluorescent detection of Cu2+ with carbon dots chelated Eu-based metal-organic frameworks

Juan Hao,Fenfen Liu,Nan Liu,Mulang Zeng,Yonghai Song,Li Wang

Here, a novel fluorescent carbon dots (CDs)@Eu-2, 6-pyridinedicarboxylic acid (DPA) metal organic frameworks (MOFs) was synthesized by encapsulating CDs into the Eu-DPA MOFs for the detection of Cu 2+ . The as-prepared CDs@Eu-DPA MOFs fluorescent probe was investigated by transmission electron microscopy, Fourier transform-infrared spectroscopy and fluorescence spectroscopy. The results showed the CDs@Eu-DPA MOFs exhibited the uniform ball-flower-like nanostructures and were very stable in aqueous solution due to their nanoscaled size and the ball-flower-like nanostructures. The CDs@Eu-DPA MOFs could emit two kinds of fluorescence which originated from CDs and Eu-DPA MOFs, respectively under a single wavelength excitation at 275   nm. In the presence of Cu 2+ , the fluorescence of Eu-DPA MOFs decreased and the fluorescence of CDs kept constant to result in ratiometric fluorescent response toward Cu 2+ when they were used as the recognition parts and the reference, respectively. The obtained CDs@Eu-DPA MOFs for the detection of Cu 2+ showed a wide linear range (50   nM–10   μM) and a low detection limit (26.3   nM) with high sensitivity, stability and selectivity. The work provides a good method to construct fluorescent sensors based on MOFs.

CAS / MDL: 7647-14-5 7447-40-7
研究领域: 材料科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2026 · IF 5.1

Microplasma-fabricated CDs@Eu-DPA for ratiometric fluorescence and smartphone-mediated visual detection of oxytetracycline in food samples

Lanlan Wei,Yilan Zhao,Yaoye Chen,Ke Huang,Xiaoli Xiong,Qing Yang

A dual-emission CDs@Eu-DPA composite was rapidly synthesized via dielectric barrier discharge microplasma technology using carbon dots (CDs), 2,6-dipicolinic acid (DPA), and Eu 3+ as precursors. CDs@Eu-DPA was subsequently applied for ratiometric fluorescence and visual analysis of oxytetracycline (OTC) in food samples. When OTC was introduced, the blue fluorescence of CDs was quenched via the inner filter effect, while OTC coordinated with Eu 3+ in Eu-DPA to form a complex, leading to the enhancement of the red fluorescence of Eu 3+ at 615 nm through antenna effect. Additionally, principal component analysis was employed to distinguish four different antibiotics, including OTC, chlortetracycline, tetracycline, and doxycycline. Under optimized conditions, the ratiometric fluorescence analysis and smartphone-assisted RGB analysis exhibited linear detection ranges of 0.05–210.0 μM and 0.3–90.0 μM for OTC, respectively, with limits of detection of 0.02 μM and 0.08 μM, respectively. The satisfactory recoveries in food samples were ultimately achieved through the dual-mode sensing method.

CAS / MDL: 499-83-2 52-90-4
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Journal of Food Measurement and Characterization · 2025 · IF 3.3

A ratiometric fluorescent probe based on Lu-Eu-DPA nanoparticles for sensitive and visual detection of gentamicin sulfate, neomycin, and erythromycin in food

Jie Mingsha,Zhu Amei,Zhu Bing,Guo Ruipeng,Lan Shengkai,He Jiaxin,Lang Xingang,Bai Yanhong

The overuse of antibiotics leads to significant health risks and environmental challenges. Therefore, selective and sensitive detection of antibiotic residues is a critical issue. Here, a double-emission ratiometric fluorescence probe (Lu-Eu-DPA) was constructed for the selective detection of gentamicin sulfate (GEN), neomycin (NEO), and erythromycin (EM). The Lu-Eu-DPA coordination polymer nanoparticles composed of luminol, the coordinated nuclear metal Eu 3+ , and 2,6-pyridinedicarboxylic acid (DPA). The coordination reaction between luminol molecules and Eu 3+ ions produce the aggregation-induced emission (AIE) effect, while DPA acts as a ligand for the antenna, absorbing energy from the excitation light and then transferring the energy to Eu 3+ . Based on the AIE effect and antenna effect (AE), the fluorescence intensity of Lu-Eu-DPA at 426 nm and 617 nm was correlated with the concentration of GEN, NEO, and EM, and the detection limits of GEN, NEO, and EM were 20, 25, and 48 nmol/L, respectively. The detection capability of the proposed method in pork samples was also studied. In addition, semi-quantitative determination of GEN, NEO, and EM was conveniently and efficiently performed using a smartphone-based visualization method. These results suggested that this probe with good selectivity and specificity was a promising method for swiftly detecting multiple antibiotic residues.

CAS / MDL: 7647-14-5 68-12-2
研究领域: 分析化学 · 食品安全 · 生物医学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
ANALYTICAL CHEMISTRY · 2025 · IF 6.7

Homogeneous Luminescence Detection Based on Lanthanide Coordination Compound

Xin Tong,Zicheng Wang,Lina Zhao,Kai Wang,Yuxin Li

Lanthanide coordination compounds (LnCC), as excellent luminophores, exhibit ultrasensitive responses to the structural details of coordination environments, providing an effective platform for chemical and biomedical detection. Due to the overtones of molecular vibrations in water that cause luminescence quenching, LnCC-based sensors are typically used in heterogeneous systems, where the compounds are dispersed as solid nanoparticles in aqueous solvents. However, this reduces sensor stability, affecting sensitivity and selectivity, and complicates mechanistic analysis. In this work, we developed homogeneous luminescence detection techniques using LnCC and investigated the underlying chemical mechanisms. The Eu-DPA coordination compound was synthesized as a homogeneous detector with good water solubility (140.3 mg/g) and excellent luminescence (92.49% quantum efficiency and >2 ms lifetime at 1 g/L concentration) via multifaceted sonication. Thanks to its homogeneous nature, the sensor achieved high sensitivity, selectivity, and stability for detecting the carcinoid marker 5-hydroxyindoleacetic acid (5-HIAA) in water, plasma, and urine. Eu-DPA exposes numerous pyridine carboxylate oxygen sites that form hydrogen bonds with the amino groups in 5-HIAA. Transient Absorption Spectroscopy (TAS) and Time-Resolved Luminescence Spectroscopy (TRES) further confirm that electrostatic interactions between the hydrogen-bonding sites significantly influence the energy transfer process, as evidenced by changes in luminescence behavior. This work not only addresses the challenge of balancing water solubility and efficient luminescence in lanthanide complexes but also offers new insights into the development of practical biomedical luminescence sensors.

CAS / MDL: 499-83-2
研究领域: 无机化学 · 分析化学 · 生物无机化学 · 传感器 · 生物医学检测 · 配位化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。