SEPARATION AND PURIFICATION TECHNOLOGY
·
2024
·
IF 8.1
Jiale Lu,Amin Jv,Hongyu Zhao,Guangbo Che,Bo Feng,Yufei Zhang,Chunbo Liu,Renquan Guan
MIL-101(Cr) is an ideal material for wastewater treatment due to its large specific surface area, excellent water stability, and chemical stability. However, its limited light absorption capacity hinders its application. We loaded ferrocene carboxylic acid (Fc-COOH) onto MIL-101(Cr) by a post-synthetic modification method, which resulted in the MOF possessing excellent optical properties while maintaining its original skeleton structure. The MIL-101(Cr)/Fc-COOH (1:2), (abbreviated as CFCC-2) exhibited the best performance, achieving a removal rate of 96% for tetracycline (TC) in just 30 min. This removal rate is significantly higher compared to MIL-101(Cr) and Fc-COOH, which achieved removal rates of only 15% and 21%, respectively. We propose a possible Z-type heterojunction mechanism between MIL-101(Cr) and Fc-COOH to explain the excellent photocatalytic performance of CFCC-2. The intermediates in TC were identified using LC-MS, and the toxicity of these intermediates was predicted and evaluated through the Toxicity Estimation Software Tool (T.E.S.T.). This study provides new insights into the design and fabrication of MIL-101(Cr)-based catalysts as photodegrading organic pollutants.
研究领域:
环境科学
·
材料科学
·
化学
✓ 已验证
产品关联
DOI
高影响因子
ACS Applied Nano Materials
·
2019
·
IF 0
Huihui Liang,Mengli Xu,Yongmei Zhu,Linyu Wang,Yi Xie,Yonghai Song,Li Wang
A uniform nanosphere derived from ferrocence-modified covalent-organic frameworks (COFETTA-TPAL-Fc(COOH)2) with 200 nm in diameter was prepared by dehydration condensation reaction between 4,4′,4′,4′- (ethane-1,1,2,2-tetrayl) tetraaniline and terephthalaldehyde in the presence of electroactive Fc(COOH)2. The Fc(COOH)2 was embedded into the layers of COFETTA-TPAL to result in the formation of nanospheres, which increased the specific surface area of the available COFETTA-TPAL to provide more active sites due to the increase in interlayer distance. The Fc(COOH)2 could interact with H2O2 which might undergo self-disproportionation process to produce O2 and be reduced into H2O simultaneously, whereas the generated O2 was directly reduced into H2O by COFETTA-TPAL. The reduction peak current of the generated O2 at −0.5 V (j–0.5 V) was gradually enhanced, whereas that of Fc(COOH)2 around 0.45 V (j0.45 V) was decreased with continuous adding of H2O2. Thus, the COFETTA-TPAL-Fc(COOH)2 nanospheres were used to fabricate a “on–off” nonenzymatic H2O2 ratiometric electrochemical sensor. The proposed “on–off” ratiometric electrochemical sensor showed good performance with a wide linear range of 1.1–500 μM, high sensitivity of 0.009 μM–1, and lower detection limit of 0.33 μM. The work would offer insights for design and preparation of electroactive COF and accelerate the practical application of COF in electroanalysis.
研究领域:
材料科学
·
电化学
·
分析化学
✓ 已验证
产品关联
DOI
IONICS
·
2017
·Vol. 23
·期 9
·2377-2385
·
IF 2.062
Pan Guangxing,Song Yonghai,Miao Longfei,Wang Li
A novel ascorbic acid (AA) electrochemical biosensor based on ferrocene dicarboxylic acid (Fc(COOH) 2 )/zeolitic imidazolate framework-8 (ZIF-8)/three-dimensional (3D) kenaf stem-derived macroporous carbon (3D-KSCs) was proposed for the first time. The formation and properties of Fc(COOH) 2 /ZIF-8/3D-KCSs nanocomposites were characterized by scanning electron microscopy, Fourier transform-infrared spectroscopy, N 2 adsorption/desorption isotherms, X-ray powder diffraction, and energy dispersive X-ray spectroscopy. The results showed that a large number of short rod-like ZIF-8/Fc(COOH) 2 was arrayed on the 3D-KSCs surface via a simple one-step hydrothermal method. Fc(COOH) 2 was firmly encapsulated into the pores of ZIF-8 simultaneously during the synthesis process of ZIF-8. The Fc(COOH) 2 /ZIF-8/3D-KCSs nanocomposites were employed to prepare integrated Fc(COOH) 2 /ZIF-8/3D-KSCs electrode directly for electrochemical AA sensing, and the integrated electrode showed better performance for AA detection than traditional enzyme-based biosensors and nonenzymatic sensors. A wide detection range of 0.06 μM~5.01 mM and a low detection limit of 0.017 μM were obtained with good stability and selectivity. The work also sheds new light on developing ZIF-8-based nanocomposites for electrochemical sensing.
ᅟ
研究领域:
材料科学
·
分析化学
·
生物传感
✓ 已验证
产品关联
DOI
高影响因子
BIOSENSORS & BIOELECTRONICS
·
2020
·
IF 10.257
Juncong Miao,Kang Du,Xuan Li,Xiaoting Xu,Xue Dong,Jinglong Fang,Wei Cao,Qin Wei
Procalcitonin (PCT) as a disease marker is of great significance in the early diagnosis of septicemia and pyemia. Biosensor have good prospects for analysis and detection of disease markers, but developing highly sensitive detection methods for detecting PCT remains a daunting task. In this paper, we develop a ratiometric electrochemical immunosensor with Au NPs modified SiO 2 -Fc-COOH complex as matrix and UiO-66 loaded with Toluidine blue (TB) as a marker for quantitative detection of procalcitonin (PCT). The SiO 2 modified by APTES not only has a large specific surface area but also contains abundant amino groups, which can be connected to the electrochemical probe of ferrocenecarboxylic acid (Fc-COOH). UiO-66 has the advantages of large specific surface area, high porosity and adjustable structure, which can adsorb toluidine blue electrochemical probe through electrostatic attraction . Measurement and analysis of the prepared immunosensor by Differential Pulse Voltammetry (DPV) show that the oxidation peak currents of Fc-COOH and TB appear at potentials of 0.30 V and −0.30 V respectively. As the PCT concentration increases, the oxidation peak current of TB increases and the oxidation peak current of Fc-COOH decreases. The ratios ( ΔI = ΔI TB /ΔI Fc-COOH ) between the double signals could show a certain linear relationship with the concentration of the PCT within a certain range. Under optimal conditions, the linear range of detection obtained by the immunosensor was 1 pg/mL-100 ng/mL and the detection limit was 0.3 pg/mL. In this work, the developed ratiometric electrochemical immunosensor not only provides a simple, reliable and sensitive strategy for quantitative detection of PCT but also provides a useful method for clinical detection of other disease markers.
研究领域:
生物传感器
·
医学检测
·
电化学分析
✓ 已验证
产品关联
DOI
PubMed
高影响因子