文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
Fe2AlB2 MAX相
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY · 2024 · IF 4.1

Dual fluorescence-colorimetric sensing platform based on the peroxidase-mimetic performance of the Fe2AlB2 MAX phase for the quantification of acetamiprid and imidacloprid pesticides

Samaneh Rashtbari,Gholamreza Dehghan,Yasin Orooji,Simin Khataee,Arezu Marefat,Leonid G. Voskressensky,Alireza Khataee

The extensive use of pesticides in modern agriculture has raised concerns about environmental contamination and adverse human health effects. Therefore, developing highly sensitive detection methods to identify pesticide residues is crucial for food safety and ecosystem protection. In this study, the Fe 2 AlB 2 MAX phase was synthesized and characterized. After evaluating its peroxidase-mimetic performance using a colorimetric method, a new, sensitive, and simple dual fluorescence-colorimetric sensor was developed for the quantification of two common pesticides, acetamiprid (ACP) and imidacloprid (IMP), using fluorescein (FL). The developed method is based on the inhibitory impact of ACP and IMP on the enzymatic performance of the Fe 2 AlB 2 MAX phase, specifically the inhibition of hydroxyl radical ( OH) generation, which enhances the absorption and emission intensities of FL. The results confirmed that OH generated through the breakdown of H 2 O 2 via the catalytic activity of the MAX phase can decrease the intrinsic absorption and emission intensities of FL. However, ACP and IMP inhibit the peroxidase-like activity of the MAX phase, leading to increased absorption and emission intensities of FL. The limit of detection values calculated for spectrophotometric and spectrofluorimetric quantifications were 2.8 μM and 0.051 μM for ACP and 1.72 μM and 0.013 μM for IMP, respectively. Furthermore, the proposed method was successfully utilized to accurately and reliably determine ACP and IMP in spiked real samples with satisfactory accuracy and precision. These developed methods offer several advantages, making them promising candidates for the direct, rapid screening of pesticide residues.

CAS / MDL: 7782-42-5
研究领域: 食品安全 · 环境科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。