文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

显示第1至12个,产品总数79个

设置提升方向
H2O2 检测
RSC Advances · 2014 ·Vol. 4 ·期 33 ·17387-17392 · IF 3.708

High-quality carbon dots: synthesis, peroxidase-like activity and their application in the detection of H2O2, Ag+ and Fe3+

Wengfeng Zhu,Jian Zhang,Zhenchao Jiang,Weiwei Wang,Xiaoheng Liu

In this paper, bright and high-quality carbon dots (CDs) were prepared by refluxing a membranous carbonized β-cyclodextrin in nitric acid. The structure and optical properties of the CDs were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), fluorescence spectrophotometry (FL), X-ray diffraction (XRD) and Raman spectroscopy. The mechanism for the formation of the CDs is also discussed. As-prepared CDs could be used as peroxidase mimics for the detection of H2O2. The results indicate that the CDs are capable of rapid and sensitive detection of H2O2 in the linear range from 2 × 10−6 to 5 × 10−4 mol L−1 and the limit of detection of H2O2 is as low as 1 × 10−6 mol L−1. More importantly, the peroxidase-like activity of the CDs is expanded to the detection of some oxidative ions (such as Fe3+ and Ag+). The linear ranges for Fe3+ and Ag+ were 8 × 10−6 to 1 × 10−4 mol L−1 and 5 × 10−6 to 1 × 10−4 mol L−1 respectively, with corresponding detection limits of 8 × 10−7 mol L−1 and 5 × 10−7 mol L−1 respectively.

研究领域: 材料科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
ELECTROANALYSIS · 2020 ·Vol. 33 ·期 4 ·947-955 · IF 2.544

Sensitive Electrochemical Detection of Pb(II) and H2O2 via a Dual-functional Sn-doped Defective Bi2S3 Microspheres

Yanqiu Fu,Jinrui Li,Wei Jin,Zhonggang Liu

In this work, a dual-functional electrochemical sensor has been proposed based on Sn-doped defective Bi 2 S 3 (TDDB) microspheres, which exhibited the excellent electrochemical performance on Pb(II) and H 2 O 2 detection. The TDDB offered a satisfied detection limit of 8.0 nM towards Pb(II) with a sensitivity of 96.7 μA ⋅ μM −1 . As a H 2 O 2 sensor, a high sensitivity of 3540 μA mM −1 cm −2 was obtained in a linear range from 0.45 mM to 10 mM with a detection limit of 10 nM. Moreover, the electrochemical detection of Pb(II) in Taihu Lake and H 2 O 2 in human serum was achieved with high reliability and good recovery.

CAS / MDL: 10035-06-0
研究领域: 分析化学 · 环境科学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Materials · 2016 ·Vol. 9 ·期 8 ·690 · IF 2.728

Synthesis of Acylated Xylan-Based Magnetic Fe3O4 Hydrogels and Their Application for H2O2 Detection

Qing-Qing Dai,Jun-Li Ren,Feng Peng,Xiao-Feng Chen,Cun-Dian Gao,Run-Cang Sun

Acylated xylan-based magnetic Fe3O4nanocomposite hydrogels (ACX-MNP-gels) were prepared by fabricating Fe3O4nanoctahedra in situ within a hydrogel matrix which was synthesized by the copolymerization of acylated xylan (ACX) with acrylamide andN-isopropylacrylamide under ultraviolet irradiation. The size of the Fe3O4fabricated within the hydrogel matrix could be adjusted through controlling the crosslinking concentrations (C). The magnetic hydrogels showed desirable magnetic and mechanical properties, which were confirmed by XRD, Raman spectroscopy, physical property measurement system, SEM, TGA, and compression test. Moreover, the catalytic performance of the magnetic hydrogels was explored. The magnetic hydrogels (C = 7.5 wt %) presented excellent catalytic activity and provided a sensitive response to H2O2detection even at a concentration level of 5 × 10−6mol·L−1. This approach to preparing magnetic hydrogels loaded with Fe3O4nanoparticles endows xylan-based hydrogels with new promising applications in biotechnology and environmental chemistry.Keywords:xylan;acylated xylan;magnetic hydrogels;Fe3O4nanoparticles;H2O2detection

研究领域: 材料科学 · 化学工程 · 分析化学 · 生物技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
RSC Advances · 2016 ·Vol. 6 ·期 71 ·66963-66970 · IF 3.289

Sphere-like CoS with nanostructures as peroxidase mimics for colorimetric determination of H2O2 and mercury ions

Haiguan Yang,Junqi Zha,Peng Zhang,Yuhao Xiong,Linjing Su,Fanggui Ye

CoS, which was prepared using a facile solvothermal method, and characterized using various analytical techniques, was demonstrated for the first time to exhibit intrinsic peroxidase-like activity. CoS catalyzed the oxidation of the peroxidase substrate 3,3′,5,5′-tetramethylbenzidine in the presence of H2O2 rendering the reaction solution blue, which is the principle used for H2O2 sensing. The mechanism of the CoS catalysis was also investigated. Under optimal conditions, the linearity of H2O2 detection ranged from 0.05 to 0.8 mM (R2 = 0.9965). More importantly, using the reducibility of glutathione and the strong affinity to thiol compounds exhibited by mercury ions (Hg2+), a novel “off–on” colorimetric sensor for Hg2+ determination was designed using CoS as a peroxidase mimics. The analytical platform for Hg2+ determination was developed, ranging from 0.25 to 3 μM (R2 = 0.9965). The limit of detection was 0.1 μM. CoS exhibited several advantageous features including good chemical stability, ease of preparation, simple purification, and excellent reproducibility.

研究领域: 生物化学 · 分析化学 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF MATERIALS SCIENCE · 2020 ·Vol. 55 ·期 13 ·5445-5457 · IF 3.553

Highly sensitive electrochemical sensing platform: carbon cloth enhanced performance of Co3O4/rGO nanocomposite for detection of H2O2

Zhang Xinmeng,Mao Zixuan,Zhao Yuanxiao,Wu Yuanting,Liu Changqing,Wang Xiufeng

Co 3 O 4 is often used to detect H 2 O 2 . However, there are many problems such as low sensitivity and the long detection time when detecting H 2 O 2 in various cobalt oxide composites. Therefore, it is a great challenge to develop different morphologies of the Co 3 O 4 electrode to improve the detection performances of H 2 O 2 effectively. In this paper, we had successfully prepared a novel Co 3 O 4 /reduced graphene oxide/carbon cloth (Co 3 O 4 /rGO/CC) composite. We used a simple template method. Co 3 O 4 nanosheets with a diameter of about 47.7 nm were obtained by using graphene oxide as a template. Then, CC was used as a three-dimensional conductive support material. CC can inhibit the agglomeration of rGO to increase specific surface area and to enhance the conductivity of Co 3 O 4 . In this study, the electrochemical performances of the Co 3 O 4 /rGO/CC electrode were tested by the electrochemical workstation. The trigger response of the modified electrode was reduced by 0.067% and the relative standard deviation was 0.013% after 30 consecutive tests. The range of linearity was 0.387–63.523 mM. Besides, this electrode has the limit of detection (0.022 μM) and a higher sensitivity (0.9683 mA mM −1  cm −2 ). It indicated that the electrode has excellent electrochemical sensing performance and high stability. These excellent performances are mainly due to the synergistic effect of Co 3 O 4 nanosheets, rGO, and CC.

CAS / MDL: 7782-42-5
研究领域: 材料科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2018 · IF 8.173

One-pot synthesis of the CuNCs/ZIF-8 nanocomposites for sensitively detecting H2O2 and screening of oxidase activity

Xue Hu,Xidong Liu,Xiaodan Zhang,Hongxiang Chai,Yuming Huang

The fluorescent CuNCs/ZIF-8 nanocomposites were facilely prepared by mixing the PEI protected CuNCs with the precursors of ZIF-8, and characterized by UV–vis absorption, fluorescence, FT-IR, TEM , XRD and XPS . The quantum yield of the CuNCs/ZIF-8 is 15 times that of the PEI-CuNCs. Furthermore, the CuNCs/ZIF-8 possesses better stability and higher fluorescence response due to protective and confinement effects of MOFs . It was found that H 2 O 2 could cause much more quenching of fluorescent CuNCs/ZIF-8 than that of PEI-CuNCs, which might result from enriching H 2 O 2 by ZIF-8. The CuNCs/ZIF-8 can be designed as a fluorescence probe to selectively and sensitively detect H 2 O 2 with a linear range from 0.01 to 1.5   µM and a LOD of 0.01   µM, while those with PEI-CuNCs are 0.5–30   µM and 0.50   µM, respectively. Through formation of CuNCs/ZIF-8 hybrid, the sensitivity for the detection of H 2 O 2 increases by nearly 50-fold, which makes CuNCs/ZIF-8 a desirable probe to detect H 2 O 2 content in human serum samples. Also, we successfully demonstrated the potential application of the CuNCs/ZIF-8 for screening and evaluating activities of oxidase using glucose oxidase as a model. The glucose oxidase activity can be detected in a range of 0.1–10   mU/L with a LOD of 0.1   mU/L.

研究领域: 生物化学 · 分析化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF ELECTRONIC MATERIALS · 2022 ·Vol. 51 ·期 4 ·1752-1758 · IF 2.047

Green Preparation of Cu Nanoparticles via Gallic Acid Applied to H2O2 Detection

Tian Wenjing,Ding Xu,Jiang Feifei,Du Xinrui,Shi Jipeng,Zhang Ji

Research into metal nanoparticles has increased, and they have been increasingly used in non-enzymatic sensor applications. However, there have been few reports on the use of natural products to prepare non-precious metal nanoparticles in an eco-friendly (green) manner. Studies were conducted on Cu nanoparticles (Cu NPs) prepared by the use of natural gallic acid (GA). This method is environmentally friendly and can be applied to H 2 O 2 detection. As-obtained Cu NPs were characterized by x-ray photoelectron spectroscopy (XPS), powder x-ray diffraction (XRD), and transmission electron microscopy (TEM). When applied to H 2 O 2 detection, Cu NPs had good sensitivity, stability, and anti-interference properties. Its electrochemical performance is no less than that of precious metal nanomaterials. Cu NPs mainly exhibit good sensitivity, reaching 5.74 μA mM -1 cm -2 ; the concentration range thereof is 1–20 mM. The process of constructing nanoparticles in this work used natural products, making it environmentally friendly and proving the practicality of constructing non-precious metal nanoparticles and the feasibility of their application to H 2 O 2 detection. Graphic Abstract

研究领域: 材料科学 · 环境科学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
NANOTECHNOLOGY · 2019 ·Vol. 31 ·期 1 ·015502 · IF 3.399

Development of nanotubes coated with platinum nanodendrites using a virus as a template

Jiawang Guo,Yuan Lin,Qian Wang

We developed a facile method to fabricate platinum (Pt) porous nanotubes coated with interconnected Pt dendrites using the tobacco mosaic virus (TMV) as a template. The surface-exposed arginine residues of the TMV induced the selective deposition of Pt seeds on the TMV outside surface, and poly(sodium-p-styrenesulfonate) (PSS) was chosen to stabilize the dispersity of TMV coated with Pt seeds (TMV/SPt). The limited space between the Pt seeds and their uniform distribution on the TMV exterior confined the growth of Pt dendrites, resulting in continuous dendritic platinum nanotubes (TMV/DPtNT). The synergistic effects of porous dendrites and anisotropic structures of the TMV/DPtNTs provided an increase in the active sites, the enhancement of transport efficiency and long-distance electron transfer, which greatly improved the catalytic activity. We also demonstrated that such nanotubes could be used in the detection of H2O2 with good sensitivity.

CAS / MDL: 50-81-7 16940-66-2
研究领域: 材料科学 · 生物纳米技术 · 化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SEPARATION AND PURIFICATION TECHNOLOGY · 2024 · IF 8.1

The construction of peroxidase-like Cu-BDC@FeMo6 for colorimetric detection of H2O2 and dopamine

Ya Xu,Jihong Zhou,Peng Sun,Ping Li,Dongxue Han,Xiaohong Wang,Fang Chai

Artificial mimic enzymes have attracted wide attention for their superior characteristics to natural enzymes in extensive applications of diagnosis and therapy. In this paper, a nanozyme Cu-BDC@FeMo 6 was designed and fabricated by embedding polyoxometalate (NH 4 ) 3 [FeMo 6 O 18 (OH) 6 ]·6H 2 O (FeMo 6 ) into a copper-based metal–organic framework (Cu-BDC). The integration of FeMo 6 and Cu MOF based on the synergies of oxidability of FeMo 6 and oxygen-driven reversible Cu + /Cu 2+ enhanced the peroxidase mimicking activity, which accomplished the sensitive visual monitoring of H 2 O 2 and dopamine (DA). The detection of H 2 O 2 was driven by Cu-BDC@FeMo 6 catalyzing the oxidation of TMB with colorimetric evolution to blue, and consecutive monitoring DA via the reverse process of reduction of ox-TMB was further achieved. The limit of detection (LOD) of H 2 O 2 and DA were 10 μM and 2.27 μM, with excellent stability, and outstanding selectivity. The mechanism of the catalysis was further evaluated, and the generation of O 2 · - played a crucial role in the catalysis for oxidation. The logic gate design was constructed to illustrate the process and application. This work provides a feasible reference for the reasonable design of simulated enzyme in biosensor applications.

研究领域: 生物传感 · 材料科学 · 仿生催化
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHEMICAL JOURNAL · 2024 · IF 4.9

Bimetallic zeolitic imidazolate frameworks-derived bar-shaped structure for electrochemical determination of H2O2

Minghong Fan,Zhiyu Gong,Jiayu Zheng,Lu Zhou,Beibei Qi,Tianzuo Liu,Zhengfei Yang

Unique nanostructures of bimetallic materials derived from zeolitic imidazolate frameworks (ZIFs) are promising candidates for electrochemical sensor applications. In this study, different bimetallic bar-shaped ZIFs (B-ZIFs) were synthesized by replacing some cobalt ions with different metals ions (Ni 2+ , Ce 2+ , Cu 2+ , Mn 2+ , or Fe 3+ ). Then their derivatives were prepared via carbonization, respectively. Upon conducting thorough material characterizations and assessment of the electrochemical properties, the most suitable candidate for electrode modification was identified as bar-shaped Co/Cu-based carbon materials (B-Co/Cu/Cs). This choice facilitated the construction of an innovative electrochemical sensor tailored for the determination of H 2 O 2 . The furnished B-Co/Cu/Cs-based sensor showed good linearity for H 2 O 2 analysis within concentrations ranged from 0.5-4000 μM and 4000–11000 μM, with a detection limit of 0.44 μM. All these results suggested that the prepared material would be a competitive candidate for the non-enzymatic H 2 O 2 sensing.

CAS / MDL: 693-98-1
研究领域: 材料科学 · 分析化学 · 电化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
NEW JOURNAL OF CHEMISTRY · 2022 ·Vol. 46 ·期 25 ·12372-12380 · IF 3.925

A series of novel Cu-based MOFs: syntheses, structural diversity, catalytic properties and mimic peroxidase activity for colorimetric detection of H2O2

Juan Chai,Luohao Yuan,Shiwei Wang,Tong Li,Mingxue Wu,Zhiwei Huang,Hongfeng Yin

Three metal–organic frameworks {[Cu6(L1)4(DMF)(H2O)2·5H2O]}n (1), {Cu3(L1)2(phen)2(H2O)}n (2) and {[Cu8(μ3-OH)3(L2)4(NO3)(H2O)5]·3H2O}n (3) utilizing nitrogen-containing heterocyclic carboxylate bifunctional ligands (L1 = 5-(4-carboxypyridin-3-yl)isophthalic acid and L2 = 2-(5-carboxypyridin-2-yl)terephthalic acid) were self-assembled hydrothermally and characterized. MOFs 1–3 possess 3D networks which consist of three different types of Cu clusters {Cu2O2(OCO)4}, {Cu2O2N4(OCO)2} and {Cu4O10(OCO)4}, respectively. MOFs 1–3 efficiently catalyze the oxidation of cycloalkanes under mild conditions. Besides, the synthesized MOFs 1–3 exhibited high peroxidase-like activity and could be utilized to catalyze the oxidation of 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid ammonium salt) (ABTS) to produce green color in the presence of hydrogen peroxide (H2O2). The steady-state kinetics experiments of the oxidation of ABTS catalyzed by MOFs 1–3 were carried out, and the kinetic parameters were obtained. The results indicated that the affinity of MOFs 1–3 towards H2O2 and ABTS was higher than that of the natural horseradish peroxidase (HRP). The as-prepared MOF 1 can be applied for the colorimetric detection of H2O2 with a wide linear range of 0.5 to 200 μM and a limit of detection (LOD) of 0.097 μM. Therefore, the novel Cu-MOFs could be regarded as promising artificial enzyme mimics in catalysis, sensors and environment analysis.

研究领域: 材料科学 · 生物化学 · 分析化学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS · 2019 · IF 3.131

Enhanced peroxidase-like activity of Fe@PCN-224 nanoparticles and their applications for detection of H2O2and glucose

Tong Li,Pei Hu,Jiawei Li,Pintong Huang,Weijun Tong,Changyou Gao

Inspired by natural hemin structure, the fabrication of metal organic framework (MOF) nanomaterials constructed by metal ions and iron porphyrin for peroxidase mimicking has attracted extensive attention recently due to their high concentration of active sites and great channeling for substrate diffusion. Herein, by using benzoic acid as capping agent, we fabricated uniform PCN-224 nanoparticles (NPs), which were composed of Zr 6 cluster and tetrakis(4-carboxyphenyl)porphyrin (H 2 TCPP). Then Fe(Ⅲ) ions were incorporated into the center of H 2 TCPP producing iron porphyrin unit similar to hemin serving as catalytic active site. The procedure of iron incorporation didn't change the size and morphology of PCN-224 NPs. The newly formed Fe@PCN-224 NPs possessed peroxidase-like activity with much lower K m values and higher K cat values than most of peroxidase-like nanozymes as well as natural horseradish peroxidase (HRP), indicating their enhanced catalytic activity. Taking advantage of the excellent peroxidase-like activity of Fe@PCN-224 NPs, we successfully developed a colorimetric method for simple and sensitive detection of hydrogen peroxide and glucose in combination with glucose oxidase .

研究领域: 生物化学 · 纳米医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。