文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
HClO检测
ANALYTICA CHIMICA ACTA · 2021 · IF 6.558

A novel ratiometric and colorimetric chemosensor for highly sensitive, selective and ultrafast tracing of HClO in live cells, bacteria and zebrafish

Feng Ding,Han Wen,Ruijiang Zhuo,Jiawei Li,Hui Zheng,Yuru Deng,Jianliang Shen,Xiaojun He

Hypochlorous acid (HClO) along with its ionic form, hypochlorite anion (ClO − ) are critical reactive oxygen species (ROS), which play vital roles in biological systems. Dysregulated production of HClO/ClO − can result in tissue damage and cause a variety of diseases. Besides, Sodium hypochlorite has been widely used as a bleaching agent for water disinfection , surface cleanin g in daily life. Excessive exposure to sodium hypochlorite will lead to symptoms of severe breathing and skin problems. Therefore, developing a state-of-the-art (simple, highly sensitive, highly selective and super fast-response) sensor for tracking HClO is of biological, toxicological, and environmental importance. Though many HClO probes have been reported so far, this big aim still presents a challenge. Researchers around the world are continuing to develop new HClO probes that could improve their sensitivity, selectivity , the limit of detection, response time, easiness to use, etc. Herein, with coumarin as the fluorophore molecule, we rationally developed a novel chemosensor ( CMTH ) for detecting HClO with both ratiometric and colorimetric responses resulted from the oxidation reaction of C N bond. Further analysis results indicated that CMTH can realize highly sensitive with low limit of detection (256 nM, among the best of its kind) and highly selective (over a bunch of interfering analytes) imaging detection of HClO in multiple organisms with low cytotoxicity, and good cell and tissue permeability as well. In particular, compared to other fluorescent HClO probes reported so far, CMTH excels in the response time to HClO (< 40 s), being the top-notch of its kind. Besides, owing to its excellent water solubility, CMTH can also be applied to track HClO in the environmental system. Taken together, we have presented here a novel chemosensor , CMTH , as a colorimetric and ratiometric chemosensor for highly sensitive and ultrafast imaging detection of HClO in aqueous solutions, eukaryotic cells, prokaryotic bacteria and vertebrate zebrafish.

研究领域: 分析化学 · 生物医学 · 环境科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY · 2025 · IF 4.6

Dual-channel ratiometric sensing of hypochlorous acid based on organic cage with red and green fluorescence

Ying Xu,Cong Dai,Zhifeng Xu

The high-performance detection of hypochlorous acid (HClO) is crucial for life and environmental health, but still challenging for the single fluorescence signal and single sensing channel of probes. Organic cage with strong adsorption ability and cage structure-related fluorescence property, is a type of potential fluorescent probe. However, the single signal and short emission of organic cage hinders its sensing performance. The design of dual emitting organic cage with long wavelength for dual-channel ratiometric sensing of HClO is of great significance. Herein, we reported an organic cage (ROX) as a probe for accurate quantification of HClO. The prepared ROX exhibited capsule topology-facilitated red/green dual emission around 660/502 nm. The cage-like structure was disrupted by the rapid specific redox interaction between imine bond in ROX and HClO. As a result, the fluorescence at 660 nm quenched in conjunction with the enhancement at 502 nm in PBS (pH 4). Besides, the fluorescence increased at 582 nm with constant emission at 480 nm in DMSO/PBS (pH 7) ( V / V , 9/1). The ratio signal in PBS and DMSO/PBS respectively gave the linearity range of 1–30 and 20–45 μM, the limit of detection (3  s ) of 14 and 49 nM, and the relative standard deviation of 1.04 % and 0.54 % for 10 replicate determinations. Based on the mutual validation of dual ratio, the dual-channel ratiometric sensing possesses good accuracy, sensitivity, selectivity, and precision. Moreover, ROX can be applied to HClO monitoring in actual water and disinfectant samples with the recoveries of spiked HClO ranged from 95.0 % to 104.2 %. The proposed sensing method highlights the great potential of organic cage in fluorescence sensing.

研究领域: 分析化学 · 荧光传感 · 环境监测 · 材料科学 · 生物分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。