文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
HDF-a细胞
CHEMICAL ENGINEERING JOURNAL · 2024 · IF 13.3

A reusable, healable, and biocompatible PEDOT:PSS hydrogel-based electrical bioadhesive interface for high-resolution electromyography monitoring and time–frequency analysis

Rongtai Wan,Jiawen Yu,Ziyi Quan,Hude Ma,Jinhao Li,Fajuan Tian,Wen Wang,Yajuan Sun,Junyan Liu,Dian Gao,Jingkun Xu,Baoyang Lu

As the most ideal interface between bioelectronic devices and biological tissues, the electrical bioadhesive interface (EBI) holds significant potential for various applications, including soft bioelectronics, wearable devices, and electrophysiological signal monitoring. However, most current EBIs are disposable products that lack repeatable adhesion and self-healing properties, thus hindering practical applications. Herein, we develop a reusable EBI by incorporating a dynamic non-covalent interaction enhancer polydopamine (PDA) and conductive PEDOT:PSS into an adhesive hydrogel matrix polyacrylamide (PAM). The EBI exhibits intriguing overall electrical and mechanical properties, including high conductivity (5.57 S m −1 ), tissue-like Young’s modulus (2.7 kPa), low interfacial impedance (1 kΩ), and excellent adhesion strength (46.45 ± 1.75 kPa on porcine skin) with excellent retention (87 %) after 200 adhering/detaching cycles, high self-healing efficiency of 94.11 %, and outstanding biocompatibility in HDF-a and HaCaT cell models. Benefiting from these superior properties, we further demonstrate the fabrication and application of an EBI-based reusable electromyography monitoring patch (EMP). The reusable EMP enables high-resolution electromyography signal monitoring capability with a higher signal-to-noise ratio (SNR) of 30.05 dB than commercial electrodes (12.06 dB). Remarkably, such reusable EMP maintains very stable SNR of 21.82 dB after 200 adhering/detaching cycles (3.8 times higher than commercial electrodes, 5.74 dB after 30 cycles), and showcases typical time and frequency-domain characteristics. These findings demonstrate a promising reusable EMP to enhance the accuracy and convenience of electromyography monitoring.

研究领域: 生物医学工程 · 材料科学 · 电生理学 · 可穿戴设备 · 软生物电子学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。